ML19317E972

From kanterella
Jump to navigation Jump to search
Accepts July 1971 Revisions to Tech Specs Per Amend 30 & 31 to OL Providing Minor Changes Are Made.Change Requirements Encl
ML19317E972
Person / Time
Site: Oconee  
Issue date: 05/17/1972
From: Peltier I
US ATOMIC ENERGY COMMISSION (AEC)
To:
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8001070767
Download: ML19317E972 (2)


Text

..

%s s

6

,~

MAY 17 '471 Note to File OCONEE TECHNICAL SPECIFICATIONS (DOCKET NOS. 50-269/270/287)

The Technical Specifications revised in July 1971 and again by Amendments 30 and 31 (Revisions 18 & 19) to the Duke Power Company application for an operating license are found to be acceptable for issuance of an operating license for Oconee Unic No. 1 provided the following minor changes are made.

It is anticipated that at a later date these Technical Specifications will need to be upgraded for Oconee Units 2 and 3 and to possible strengthen them in the areas of future Appendix I (10 CFR 50) requirerents and guidance issued in Safety Guides 16 and 21 once operating experience has been acquired.

For reference purposes a copy of the marked un Technical Specifications is attached.

I f,b'h owe I. A. Peltier cc:

I. Peltier, DL (2)

A. Schwencer, DL R. C. DeYoung, DL Docket 1

J s ooxon 7p )

i o

CHANCES REOUIRED TO MAKE ThE TECHNICAL SPECIFICATIONS (THRU REVISION 19) ACCEPTABLE Page 1-5

- 1.8-c - Delete "as defined by 10 CFR 20"

- 1.8-d - Insert "or reactor protective system" between

" system' and " component in first line.

Face 2.1-3

- Fifth line, typo, "because."

Page 3.1-7

- Page not numbered.

Pace 3.3-2

- 3.3.3-c - Change "only one" to "no more than one."

Page 3.5-10

- First set point on chart; typo; change "30" to "10."

- Same in first line under "High Reactor Building Pressure."

Page 3.6-1

- 3.6.3, 3.6.4, - Since these are e containment specification:,

they should be stated in the positive sense.

For example; 3.6.3 "The containment integrity shall be intact whenever positive reactivity insertions which would result in 3.6.4 "The reactor building inter'nals pressure shall not exceed 1.5 usig or 5 inches Hg Pace 4.1-5

- Items 16, 18, 20 - Change "B/M" to "M" in the " Test" Column.

and 4.1-6 Page 4.1-7a

- Item 49 - Change "R" to "P" in the " Test" Column.

l-Pace 4.11-1

- Last paragraph under " Bases" - add words "and as low as practicable" after "10 CFR 20."

- This specification must be expanded to include non-rad-weste, thermal and oxygen content surveillance.

Pane 4.14

- This specification must include the testing and replacine of charcoal absorbers used in the radiation monitors for Iodine.

Page 6.1-1

- Second line of " Introduction," - delete "that."

Pne. 6;1-2

- 6.1.1.7 - This specification should state that at least one member of each shif t is familar (in a cualified sense) with the station't radiation protection procedures and treets the reauirements of a health physics technician.

~

y

,-,-,y v.

-mm


o