ML19317D912

From kanterella
Jump to navigation Jump to search
Forwards Revised Abnormal Occurrence Rept AO-269/74-14
Date released: 11/27/2019 Download: ML19317D912


Revised Abnormal Occurrence Rept AO-269/74-14:on 741005,4 Gallon Per Minute Reactor Coolant Leak Found.Caused by Leaking Diaphragm in Pressure Switch 1PS-364.Switch Isolated & Removed,Piping Capped
ML19317D920
Person / Time
Site: Oconee 
Issue date: 10/18/1974
From:
DUKE POWER CO.
To:
References
Download: ML19317D920 (2)
Forwards Revised Abnormal Occurrence Rept AO-269/74-14
ML19317D903
Person / Time
Site: Oconee 
Issue date: 10/25/1974
From: Thies A
DUKE POWER CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19317D903 (2)