ML19317D851

From kanterella
Jump to navigation Jump to search
Forwards RO-269/77-16
Date released: 11/27/2019 Download: ML19317D851


RO 269/77-16:on 770507,primary-to-secondary Sys Leakage Revealed in 1B once-through Steam Generator.Caused by Circumferential Crack in Tube 15,row 17.Cracked & Questionable Tubes Were Explosively Plugged at Both Ends
ML19317D856
Person / Time
Site: Oconee 
Issue date: 05/20/1977
From:
DUKE POWER CO.
To:
References
Download: ML19317D856 (4)
Forwards RO-269/77-16
ML19317D850
Person / Time
Site: Oconee 
Issue date: 05/23/1977
From: Parker W
DUKE POWER CO.
To: MOSELEY N C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19317D850 (2)