ML19317D610

From kanterella
Jump to navigation Jump to search
Forwards B&W Rept Re Design Deficiency in Internals Handling Fixture Spherical Nut Retaining Devices.Mod to Spherical Nut Retaining Device Completed at Facility
ML19317D610
Person / Time
Site: Oconee  
Issue date: 09/20/1974
From: Thies A
DUKE POWER CO.
To: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19317D611 List:
References
NUDOCS 7912060850
Download: ML19317D610 (2)


Text

._

(*

DLUCE POWER COMP [ Y Powen Buxtorwo 422 SouTu Cnunen STncer, CnAntorrs, N. C. monot A. C. Testos, se. oa v.cc Nr6.c =>

P O. Box c:70 PacDUCfsD> a=c TeahnwaS610h September 20, 1974 Mr. Norman C. Moseley, Director Directorate of Regulatory Operations U. S. Atomic Energy Commission Region II - Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Re:

Oconee Nuclear Station Docket Nos. 50-269, -270, -287 i

Dear Mr. Moseley:

The Babcock and Uilcox Company has informed us of a deficiency in the design of the internals handling fixture spherical nut retaining devices in use at Oconee Nuclear Station. Attached is a B&W report documenting their generic investigation of this deficiency.

Modification to the spherical not retaining device has been completed on Oconee Units 1, 2, and 3.

This modification consists of attaching a plate to the bottom of the threaded rod to prevent the spherical nut unthreading.

Very truly yours, W

~

A. C. Thies ACT:vr Attachment l

l t

I 5

y/gDbD D-o P

=

.-