Responds to NRC 760802 Request for Addl Info Re Amend to Tech Specs Increasing Upper Ph Limit in Chemical Effluents from Facility from 8.5 to 9.0
ML19317D547
Person / Time
Site: Oconee  
Issue date: 09/29/1976
From: Parker W
DUKE POWER CO.
To: Rusche B
Office of Nuclear Reactor Regulation
References
NUDOCS 7912060795
Download: ML19317D547 (2)


Text

.~

n Duxz POWER CO>fPM

~

Powen Brit.nswo 4r: SocTn Cucucn SrnerT, CnutorTE, N. C. asa-sa m w. o **a ca..,a.

September 29, 1976 v.c, ecvoie

.c. : c.

.c. m D ia ns Pe oD s Chose 2'3 406)

/

r., p..,)

/j

.C i

Mr. Benard C. Rusche, Director Nuclear Reactor Regulation b

hlb-b.,, '

y *gQy.,g" U. S. Nuclear Regulatory Commission T

Washington, D. C.

20555

^*cQ.

Attention: Mr. A. Schwencer, Chief b

Operating Reactors Branch #1 l

r,-

RE: Oconee Nuclear Station j

Docket Nos. 50-269, -270, -287 rw, t e:

My tetter of May 13, 1976 proposed an amendment to the Oconee Nuclear Station Appendix B Technical Specifications to increase the upper limit of pH in chemi-cal effluents from the station from 8.5 to 9.0.

In response, your letter of August 2, 1976, identified and requested additional information required before an evaluation of this proposal could be completed.

Pursuant to this request, the following information is herewith submitted:

To evaluate the effect of this revision, a study based on alkalinity was per-formed to better assess the effect of Oconee chemical effluents on the Keowee receiving waters. A theoretical model was developed for the effluent discharge plume based on eddy diffusion, mixing length, entrainment, and width growth models in turbulent flow. This model does not take into account chemical reaction (buffering or neutralization), and is therefore, highly conservative.

The chemical effluent discharge plume was modeled for two sets of conditions.

A worst case condition was considered for which the effluent discharge stream had a maximum alkalinity value of 26.5 mg/l as Caco 3 equivalent and a maximum effluent flow of 22.8 cfs.

Similarly, a normal case condition was considered in which effluent stream alkalinity and flow values were 7.5 mg/l as Caco 3 equivalent and 7.7 cfs respectively.

The above values are consistent with data obtained at Oconee and are likewise consistent with alkalinities of typical Piedmont South Carolina streams as reported in the "U.

S. Geological Survey Water-Data Report SC-76-1."

For the worst case, the alkalinity of the effluent discharge would be dis-persed to 8.4 mg/l as Caco 3 equivalent after 250 feet of mixing with the Keowee receiving waters. For the normal case, the effluent alkalinity would be dispersed to 8.5 mg/l as Caco 3 equivalent after 30 feet of mixing.

These values are slightly higher than the average background Keowee River alkalinity of 7.5 mg/l as Caco 3 equivalent and indicate that mixing of the effluent stream with the Keowee receiving waters will result in no significant change to the pH or the alkalinity of the receiving water with the exception of a very small area near the discharge points.

791206u p f

Mr,. B: nard C. Rucche

~

Page'2

  • September 30, 1976 i

The above conclusion is supported by data obtained on March 16,1976, when current technical specification limits were exceeded inadvertently by releasing chemical effluents with a pH of 8.7 and an alkalinity of 23.0 mg/l as Caco 3 4

equivalent.

Following this incident, no discernible difference was measured in the alkalinity upstream and approximately 1600 feet downstream of the discharge.

i It is concluded that chemical effluents released from Oconee Nuclear Station with a pH of 9.0 would have insufficient alkalinity to affect anything other than a very small localized area near the release point.

Therefore, increasing the pH effluent release limit to this value would have no overall effect on any aquati species.

Ver truly yours, q

i J

u. :,,,. 0.

_2.-

William O. Parker, Jr EDB:ge l