ML19317D231
| ML19317D231 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 06/09/1978 |
| From: | Parker W DUKE POWER CO. |
| To: | Case E, Reid R Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19317D233 | List: |
| References | |
| NUDOCS 7911190615 | |
| Download: ML19317D231 (4) | |
Text
hh D f}
~
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
DISTRIBUTION FOR INCOMING MATERIAL so-?Ao 270/287 REC: CASE E G ORG: PARKER W O DOCDATE: 06/09/78 NRC DUKE PWR DATE RCVD: 06/12/7 DOCTYPE: LETTER NOTARIZED: YES COPIES RECEIVED SUDJECT:
LTR 3 ENCL 40 FORWARDING LIC NOS DPR-39, 47 & 55 APPL FOR AMEND: TECH SPEC PROPOSED CHANOE CONCERNING REVISION TO TECH SPEC 3.9 " RELEASE OF LIQUID RADIOACTIVE WASTE",
TO DELETE SEVERAL REQUIREMENTS NO LONGER APPLICABLE TO THE LIQUID EFFLUENT MONITORING SYSTEM NOTAR PLANT NAME: OCONEE - UNIT 1 REVIEWER INITI AL:
XJM OCONEE - UNIT 2 DISTRIRUTER INITIAL:$(.
OCONEE - UNIT 3
- DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ******************
NOTES:
1.
M.
CUNNINGHAM - ALL AMENDMENTS TO FSAR AND CHANGES TO TECH SPECS CHANGE REQUESTS FOR ENVIRON TECH SPECS (APPEND B)
(DISTRIBUTION CODE COO 4)
FOR ACTION:
BR CMTre ORB #4 BC**W/5 ENCL INTERNAL:
rG FIL
- W/ ENCL NRC PDR**W/ ENCL
. *W/2 ENCL GELD **W/ ENCL GOSSICK & STAFF **W/ ENCL QAB**W/ ENCL AD FOR OPER TECH **LTR ONLY EEG**W/ ENCL J MCGOUGH**W/ ENCL DIRECTOR DSE**LTR ONLY ENVIRO SPEC DR**W/ ENCL AD FOR SITE ANLYS**LTR ONLY EFFLUENT TREAT SYS**W/ ENCL RAD ASSESSMENT ER**W/ ENCL EXTERNAL:
LPDR'S WALHALLA, SC**W/ ENCL NATL LAB ORNL**W/3 ENCL NSIC**W/ ENCL TIC **W/1 ENCL ACRS CAT B**W/16 ENCL 9
CHECK NER: 196,100 AMOUNT:
$4,800.00 CHECK AND COPY OF TRANSMITTAL LTR ADVANCED TO W.
MILLER (LFMB) (06/13/78) UPON RECIEPT 01$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
4 DISTRIBUTION:
LTR 43 ENCL 40 CONTRCL NER:
781630102 SIZE: 3P+3P oo*************++******************
THE END
- a
.T911190b/6
r3 j.
c r.
s DUKE POWER COMPANY Powsm Dunmswo 42u SocTa Cacaca Starzt, CHAntoTTs, N. C. asa4a wau4= o. ** a n a. s a.
June 9, 1978 WCf P#tStDres?
IC;.CP=O4 t; AR C4 704 5'ta= Paoovetic=
37b4063 Mr. E. G. Case, Acting Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washfngton, D. C.
20555 Attention: Mr. R. Reid, Chief Operating Reactors Branch #4
Reference:
Oconee Nuclear Station Docket Nos. 50-269, 270, -287
Dear Sir:
Pursuant to 10CFR50, 550.90 please find attached a proposed revision to Oconee Nuclear Station Technical Specification 3.9, " Release of Liquid Radioactive Waste."
Specification 3.9 has been revised to delete several requirements that are no longer applicable to the liquid effluent monitoring system currently installed at Oconee, since an off-line monitor has been permanently installed.
This monitor, manufactured by General Atomics Corporation, is capable of the following:
1.
Assuring an adequate flow through the monitor with an installed adjustable orifice and rotameter. This decreases the possibility l
of inadequate flow affecting the monitor reading.
I 2.
Maintaining the photomultiplier tube and scintillation crystal j
at a constant temperature. This decreases the possibility of rapid temperature changes causing cracking of the scintillation crystal j
and/or affecting the voltage output of the photomultiplier tube.
3.
Flushing the monitor sample chamber and piping from the liquid waste tanks to the monitor between effluent releases. This capability was provided to decrease " spiking" at the beginning of liquid effluent releases. Flushing also decreases the buildup l
rate of contamination in the sample chamber and pipiag.
Operation with this system as currently installed and in accordance with this proposed specification, assures compliance with the limits of 10CFR20.
l 791630102 fg b9p d
3
-)
Mr. E. G. Case, Acting Director Page Tdo June 9, 1978 4
In addition to requesting that this revision be approved, it is requested that a previous proposed revision, concerning this same specification, and submitted in my letter of November 18, 1976 be withdrawn from further review.
i o
I.
This proposed license amendment package is considered to constitute one Class III amendment and two Class I amendments since they involve a single issue pertaining to three identical units. Accordingly, the enclosed check in the amount of $4,800 is remitted for the license amendment fee.
Ver truly yours, 1
Mu us &r
/
William O. Parker, Jr.
RLG:scs Attachment l
1 i
i I
1 l
l l
i
m
--E Mr.- E. G. Case, Acting Director Page Three June 9, 1978 WILLIAM 0. PARKER, JR., being duly sworn, states that he is Vice President of Duke Power Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission this request for amendment of the Oconee Nuclear Station Technical Specifications, Appendix A to Facility Operating Licenses DPR-38, DPR-47 and DPR-55; and that all statements and matters set forth therein are true and correct to the best of his knowledge, s
.Q u.a.5 6.
William O. Parker, Jr.7 Vice President Subscribed and sworn to before me this 9th day of June,1978.
W&n_
kWs Notary Public My Commission Expires February 15, 1982
-