.e BARRIER FUEL PROGRAM i

DEVELOP FUEL MORE RESISTANT TO PCI DOE SPONSORED PROGRAM BEGINNING IN 1977 i

EXTENSIVE PREVIOUS RESEARCH TWO POTENTIAL DESIGNS IDENTIFIED o

COPPER BARRIER i

I o

ZIRCONIUM LINER l

i e

JC:sLx/1327 3/25/80 8005280 89 %

PROGRAM STATUS EXTENSIVE TESTS TO VERIFY PCI RESISTANCE HAVE BEEN PERFORMED.

DESIGNS TESTED UNDER SIMULATED ACCIDENT CONDITIONS, FOUR ASSEMBLIES OPERATING IN QUAD CITIES 1.

DEMONSTRATION NUCLEAR DESIGN COMPLETED, PREPARED TO LICENSE AND MANUFACTURE DEMONSTRATION RELOAD M

JC: JLK/1328 3/25/80

MEETING PURPOSE PROVIDE BACKGROUND INFORMATION ON PROGRAM o

TEST RESULTS o

PLANNED DEMONSTRATION o

EDIS0N VIEWPOINT i

OBTAIN AGREEMENT ON DEMONSTRATION LICENSING DOCUMENTATION AND SCHEDULE, i

l l

- JC:atx/1329 3/25/80 1

T 7.~.

r BARRIER FUEL PRESENTATION AGENDA l

l W

INTRODUCTION J. S. CHARNLEY PROGRAM DESCRIPTION AND STATUS H. S. ROSENBAUM EDISON PERSPECTIVE D. R. O'B0YLE CONCLUSION J. S. CHARNLEY SCHEDULE AGREEMENT NRC JC:atK/1330 3/25/80

~

r i

DEMONSTRATION FUEL DESIGN ZIRCONIUM LINER SELECTED I

o TWO PURITY LEVELS f

i o

SAME AS TWO QUAD CITIES 1 ASSEMBLIES i'

COMPARIS0N TO CURRENT P8 x 8R DESIGN o

3 MIL LINER, METALLURGICALLY BONDED l

o EXTERIOR DIMENSIONS SAME o

INSIDE TUBE DIAMETER SAME o

ZIRCONIUM PHYSICAL, CHEMICAL AND NUCLEAR PROPERTIES SIMILAR TO ZIRCALOY o

SOME BUNDLES OF SLIGHTLY HIGHER ENRICHMENTS FOR DEMONSTRATION MINOR CHANGE IN i

FUEL DESIGN JC: JLK/1331 3/25/80 l

4 4

LICENSING PERSPECTIVE MINOR CHANGE IN FUEL DESIGN 7

q' 3, P0TENTIAL TECH. SPEC CHANGE FOR E0C LOCALIZED POWER RAMPS ph ECCS LIMITS FOR NEW FUEL TYPE

'J-NO REVISIONS TO SAFETY ANALYSES METHODOLOGY JC: JLK/1332 3/25/80

DEMONSTRATION RELOAD LICENSING TWO-PHASE LICENSING o

GENERIC PROGRAM DOCUMENT o

PLANT / CYCLE UNIQUE LICENSING GENERIC DOCUMENT APPROVAL o

CONSISTANT WITH QUAD CITIES 2 CYCLE 6 o

EDISON DECISION DATE o

MANUFACTURING REQUIREMENTS 4

JC: Jtx/1333 3/25/80

MR cTA GENERIC PROGRAM DOCUMENT

_ t m. <T,-> i' N SIMILAR IN SCOPE TO RELOAD LTR INCLUDE DEMONSTRATION DESCRIPTION

~

REFERENCE GENERIC RELOAD LTR WHERE APPLICABLE o

SAFETY ANALYSIS METHODOLOGY o

APPLICABLE ANALYTICAL RESULTS PROVIDE INFORMATION/ ANALYTICAL RESULTS DIFFERENT FROM THE GENERIC RELOAD LTR w

o INTERNAL FUEL CLADDING GE0 METRY - NO CREDIT FOR LINER STRUCTURAL STRENGTH o

STANDARD ENRICHMENT RELATED INFORMATION o

LINER MATERIAL PROPERTIES AS REQUIRED o

RELEVANT LTA/ TEST INFORMATION o

ADDITIONAL MANUFACTURING QUALITY ASSURANCE

~

JC: JLK/1334 3/25/80

SCllEDULE F0il GENERIC APPROVAL NRC SUBMITTAL MAY 1980 3

APPROVAL REQUIRED OCTOBER 1980 l

PLANT / CYCLE UNIQUE SCHEDULE BEGINS NOVEMBER 1980 m

JC:stx/1340 3/25/80 t

w o

a

=

s m..,

e m

+

+

PLANT / CYCLE UNIQUE LICENSING AMEND'ECCS REPORT ECCS/ DEMONSTRATION TECH SPEC, REVISIONS STANDARD CYCLE UNIQUE LICENSING e

I JC: JLK/1341 3/25/80 i

- +es

- eeew ew =.*

eg-e.

-e

-eme eM--

.w-w e

- e eem.

.