Forwards IE Bulletin 80-10, Contamination of Nonradioactive Sys & Resulting Potential for Unmonitored,Uncontrolled Release to Environ. Response Required Only by Facilities W/Ol
ML19316A684
Person / Time
Site: Big Rock Point, Palisades  File:Consumers Energy icon.png
Issue date: 05/06/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Dewitt R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 8005230347
Download: ML19316A684 (1)


Text

4 QQ a tteuq'o, 8

UNITED STATES

[ ] ),f, g

NUCLEAR REGULATORY COMMISSION

.- c REGION 111 e

\\..... d['

799 ROOSEVELT ROAD o,

GLEN ELLYN, ILLINOIS 60137 Docket No. 50-155 MAY DE Docket No. 50-255 Consumers Power Company ATTN:

Mr. R. B. DeWitt Vice President Nuclear Operations 212 West Michigan Avenue Jackson, MI 49201 Gentlemen:

Enclosed is IE Bulletin No. 80-10 which requires action by you with regard to your power reactor facilities with an operating license.

For facilities with a construction permit, no action is required; the Bulletin is providing information only.

Should you have questions regarding this Bulletin or the actions required of you, please contact this office.

Sincerely, gg f [71 cts.1" -

lcv

\\

v James G. Keppler Director

Enclosure:

IE Bulletin No. 80-10 cc w/ encl:

Mr. D. P. Hoffman, Nuclear Licensing Administrator Mr. C. J. Hartman, Plant Superintendent Mr. J. G. Lewis, Manager Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Ronald Callen, Michigan Public Service Commission Myron M. Cherry, Chicago 1

8 0 05 L30 347

)

O SSINS No.: 6820 UNITED STATES Accessions No.:

NUCLEAR REGULATORY COMMISSION 8002280677 0FF:CE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 May 6, 1980 IE Bulletin No. 80-10 CONTAMINATION OF NONRADI0 ACTIVE SYSTEM AND RESULTING POTENTIAL FOR UNMONITORED, UNCONTROLLED RELEASE OF RADI0 ACTIVITY TD ENVIRONMENT Description of Circumstance At the Brunswick Nuclear Facility, the auxiliary boiler was operated for an extended period of time with radioactively contaminated water in the boiler 2

at levels up to 2 x 10 micro curies per milliliter.

A tube leak in the firebox of the oil fired auxiliary boiler resulted in an unmonitored, uncon-trolled release of radioactivity to the environment.

The initial contaminating event was caused by the use of a temporary heating hose from the auxiliary boiler to a radioactive waste evaporator concentrate tank.

Upon cooling and condensation of the steam in the temporary hose, contam-inated water siphoned from the concentrate tank back to the auxiliary boiler.

Due to additional, continuing leaks in the heat exchanger of the waste evaporator (to which the auxiliary boiler also provides process steam), the licensee's efforts to decontaminate the auxiliary boiler feedwater had been ineffective.

Maintenance of proper boiler chemistry was difficult because blowdown options were severely restricted due to the contamination.

As a result, a boiler tube failure caused on the order of 100 millicuries of radioactive material to be released off-site via the auxiliary boiler fire box and smokestack in the form of steam.

This resulted in increased environmental levels of cesium and activa-tion products being detected as far as eight miles downwind from the site boundary.

Action to be Taken by Licensee with an Operating License 1.

Review your facility design and operation to identify systems that are considered as nonradioactive (or described as nonradioactive in the FSAR), but could possibly become radioactive through interfaces with radioactive systems, i.e., a nonradioactive system that could become contaminated due to leakage, valving errors or other operating conditions in radioactive systems.

In particular, special consideration should be given to the following systems:

auxiliary boiler system, demineralized water system, isolation condenser system, PWR secondary water clean-up system, instrument air system, and the sanitary waste system.

l 2.

Establish a routine sampling / analysis or monitoring program for these i

systems in order to promptly identify any contaminating events which could lead to u.nmonitored, uncontrolled liquid or gaseous releases to the environment, including releases to on-site leaching fields or retention ponds.

~

s IEBulleti[No.80-10 May 6, 1980 Page 2 of 2 3.

If these nonradioactive systems are or become contaminated, further use of the system shall be restricted until the cause of the contamination is identified and corrected and the system has been decontaminated.

Decon-tamination should be performed as soon as poss.ble.

However, if it is considerej necessary to continue operation of the system as contaminated, an immediate safety evaluation of the operation of the system as a radio-active system must be performed in accordance with the requirements of 10 CFR 50.59. The 10 CFR 50.59 safety evaluation must consider the level of contamination (i.e., concentration and total curie inventory) and any potential releases (either routine or accident) of radioactivity to the environment.

The relationship of such releases to the radioactive effluent limits of 10 CFR 20 and the facility's Technical Specification and to the environnental radiation dose limits of 40 CFR 190 must also be evaluated.

The record of the safety evaluation must set forth the basis and criteria on which the determination was made.

4.

If it is determined in the 10 CFR 50.59 safety evaluation that operation of the system as a radioactive system is acceptable (i.e., does not involve an unreviewed safety question or a change to the Technical Specifications), provisions must be made to comply with the requirements of 10 CFR 20.201, General Design Criterion 64 to 10 CFR 50, Appendix I to 10 CFR 50 and the facility's Technical Specifications.

In specific, any potential release points must be monitored and all releases must be con-trolled and maintained to "As Low As is Reasonably Achievable" levels as addressed in Appendix 1 to 10 CFR 50 and within the corresponding environ-mental dose limits of 40 CFR 190.

However, if in the 10 CFR 50.59 determination it is determined that operation of the system as a radio-active system does constitute an unreviewed safety question or does require a change to the Technical Specifications, the system shall not be operated as contaminated without prior Commission approval.

Actions tal.en in response to Items 1 and 2 above shall be completed within 45 days from the date of this Bulletin.

A verification letter shall be submitted within an additional 15 days to the Director of the appropriate NRC Regional Office.

This letter shall document the completion of the required actions but need not delineate the specific actions taken.

The specifics shall be docu-mented and made available to the NRC for review during future onsite inspection efforts.

For facilities with a ccnstruction permit, no action is required.

The Bulletin is provided for information.

The subject of the Bulletin and the action required of operating plants should prove useful in the planning of systems designs and future operations.

Approved by GAO, B180225 (R0072); clearance expires 7-31-80.

Approval was given under a blanket clearance specifically for identified generic problems.

  • 3 May 6, 1980 RECENTLY ISSUED IE BULLETINS Bulletin Subject Date Issued Issued To No.

80-09 Hydramoter Actuator 4/17/80 All power reactor Deficiencies operating facilities and holders of power reactor cps 80-08 Examination of Containment 4/7/80 All power reactors Liner Penetration Welds with a CP and/or OL no later than 4/7/80 80-07 BWR Jet Pump Assembly 4/4/80 All GE BWR-3 and Failure BWR-4 facilities with an OL 80-06 Engineered Safety Feature 3/13/80 All power reactor (ESF) Reset Controls facilities with an OL 80-05 Vacuum Condition Resulting 3/10/80 All PWR power reactor In Damage To Chemical Volume facilities holding Control System (CVCS) Holdup OLs and to those with Tanks a CP 80-04 Analysis of a PWR Main 2/8/80 All PWR reactor facilities Steam Line Break With holding OLs and to those Continued Feedwater nearing licensing Addition 80-03 Loss of Charcoal From 2/6/80 All holders of Power Standard Type II, 2 Inch, Reactor OLs and cps Tray Adsorber Cells 80-02 Inadequate Quality 1/21/80 All BWR licenses with Assurance for Nuclear a CP or OL Supplied Equipment 80-01 Operability of ADS Valve 1/11/80 All BWR power reactor Pneumatic Supply facilities with and OL 79-01B Environmental Qualification 1/14/80 All power reactor of Class IE Equipment facilities with an OL i