Distribution:

e Guppl.

1 L Rdg.

OSB Rdg.

DFKnuth, L:TR Nov s 0 19n y'

R. C. DeYoung, Assistant Director for PWR's, L RESP 0:iSE TO TECIUtICAL ASSISTNiCE REQUEST - OCOME REVIEW 0F TECHNICA.L SPECIFICATIONS (SECTIO 16)

Oconee Nuclear Station Unit 2 & 3 Plant fla::o:

OL Licensing Stage:

50-270/287 Docket rios.:

Branch & Project Manager L:PUR-4, I. A. Peltier Requesting Assistance:

L:0SS Technical Review Branch Involyad:

11/29/72 Requested Corpletion Date:

Review Section 6 of Technical Description of Review:

Specifications for Units 2 & 3 (Revision 24)

~

Complete Review Status:

k As requested infonr. ally, work has been completed as ind Our conclusions are contained in the attached report.

above.

i D. F. Knuth, Assistant Director for Reactor Safety Directorate of Licensing Enclosures As stated ccw/cncl:

S. H. Hanauer, DRTA J. M. Hendrie, L:TR A. Schwancer, L:PWR-4

1. A. Peltier, L:PWR-4 R. W. Houston, L:0SB '

h C. R. Van fliel, L:05B

'cc w/o enc 1:

W. licDonald, L:0PS E

,,) r, g. ;

H j

7 L:09

),...

L:TR...-

..L:0SB...._

omcc.

A RW' b ~nb_.- DF r

c1 su%iue fR

~ ~ _.... ~.

-).....

' D ATE >

8001130 Q/[

[

g Form AEC.318 (Rev. 9-53) AECM 0240

Section 6 of Technical Specifications Oconee 2 & 3 Docket tios. 50-270/289

(

Section Comments 6.1.1.6.b.

Add the words "per unit", after "and one Senior Reactor Operator."

6.1.1.6.e.

Add the words "for each unit" after "At least one operator per shift."

6.1.1.6.f.

Add a new item as follows:

f.

If the computer for a reactor is inoperable for more than eight (8) hours, an additional operator will be called in to supplement the shift crew.

Table 6.1-1 Add "R0" in the Minimum Qualifications column for the Assistant Control Operator.

Submit a revised Table 6.1-1 for 3-unit operation that meets the minimum shift complement specified in the 8/15/72 letter, e.g.:

"For three-unit operation, we have concluded that the minimum shift complement shall be eleven.

This crew is composed of three licensed Senior Reactor Operators, four persons with Reactor Operator Licenses, and four unlicensed operators."