ML19316A568

From kanterella
Jump to navigation Jump to search
Forwards Errata to BAW-1437, Analysis of Capsule OC11-C from Oconee 2 Reactor Vessel Matls Surveillance Program
ML19316A568
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 06/30/1977
From: Parker W
DUKE POWER CO.
To: Case G
Office of Nuclear Reactor Regulation
References
NUDOCS 8001100784
Download: ML19316A568 (3)


Text

h76)

FI WE NRC DISTRIBUTION FcR ART 50 DOCKET MATERI AL DATE bF DOCUMER$t FROM: DUKE POWER CO.

o 6 O/77

  • U*

A CHARLOITE, N.C.

W.O. PARRER, JR.

DAT VED

$ETTER ONdTORIZED PROP INPUT FORM NUMBER OF COPtES RECElvEO ConciN AL uncLASSIFIE D ff %QP. b- (r 77 tik.

T/Ji $

t cucuosu"e EscasPTaon

[

ERRATA TO BAW-1437, JUNE 1977 REPORT "ANALYSMS OF CAPSULE OCllC FROM DUKE POWER CO OG,0 NEE U::IT

.(

g 2 REACTOR VESSEL MATERIAL SURVEILLANCE PROGRdi".

r

/

6 (IP & IP)

DO NDHMDE

~

AC7diOWLEDGED.

PLANT NAME:

OCONEE # 2, aab FOR ACTION /iNFORMATION ENVIRfRilENTAL cAFEqv ASSIGb1D_AD_t ASSIGNED AD:

V. M') ORE (LTR)

/

upa.NCH CHIEEt

( Ch ujc ncap- [S?

BRANCH CHIEF:

E PROJECT E !AGER:

3kboFi PROJECT MANAGER:

[

LICENSING ASSISTANT:

A %d LICENSING ASSISTANT:

B. HARLESS

'i INTERNAL DISTRIBUTION rc 7TLEd j SYETJMS SAFETY l

PLANT SYSTEMS l

SITE SAFETY &

Ml M 1/

5P M P.

HEINNAN TEDESCO L ENVIRON ANALYSIS

~

I/kT 4 E l%/

SCHROEDER BENAROYA DENTON & MULLER I

TAINAS CFFTCHFTFTD f

netn

<GOSSICK & STAFF ENGINEERING IPPOLITO

~

I/!uaNmro 1(NTCHT F. ROSA ES"IIRO TECH.

l iuToc POSNAK ERNST V

SIEVELL l OPERATING REACTORS 3ALLARD aj ra r:F i unyn PAWLICKI l

STELLO VOUNGELOOD N

ETSENHUT D903FCT MANACFF7NT REACTOR SAFETY SHAO

' cifnvunLT ROSS b

BAER I P. Cet LTNS NOVAK

/

BUTLER GAMMILL (2)

MOUS ION

. ROSZTOCZY

[

GRIMES

)IvetT2

/

CHECK SITE ANALYSIS VOLLMER MELTvvrS SK AT&I

, BUNCH l

SALTZMAN

/

J. COLLINS KREGER l

_RUTBERG

[

y j

,EJTERNAL DISTRIBUTION CONTR OL NUMBER

)

/T LPDRs (d/d/hd//L 3G l

{,5 y

[ TIC

~

/ NSIC P

NAT LAB _ _ _ _ _ _, _ _.__ _

REG IV (J. HANCHETT)I l 4

771870C46

[ 16 CYS ACRS SENT CAI! GORY f)

I I 8001100 g y

/

DUKE POWER COMPANY l'uwru llen. nmo 4'.! Socras Csicucs: Srarer. C sAutorrr. N. C. ute.m t

/~..

.,u i. a Q PA R m E R,.A R.

June 30, 1977 y gr Pet St LE**T 5 7[ame PooDsCT'OM TELE **a0*sCl Amta 704 3 73 40(p 3 Mr. Edson G. Case, Acting Director Of fice of Nuclear Reactor Pegulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 go,g, Re:

Ocoace Nuclear Station geg@

Docket No. 50-270

Dear Sir:

My letter of June 6,1977, provided report BAW-1437, June,1977 " Analysis of Capsule OC11-C from Duke Power Company Oconee Unit 2 Reactor Vessel Riterials Survefilance Program".

Several minor errors have been identified in that report.

Please find attached 40 copies of an errata for this report.

Very truly yours, i

b<ffde 0 ads s

William O. Parker, Jr.

,,a-

~

MST:ge

.3 Attachment

/

o 3

x Q

I(,

J L)

C; JUL 51977> j W,3, HucttAt nasucet

~

i l

cwmese N

2, "w

133 s.

N-771370046

j I

THE BABC0CK & WILC0X COMPANY F

POWER GENERATION. GROUP l Distribution To i

f i

from t

A. L. Lowe, Jr., PE, et al.

sos 663.s l

4 File No.

I Cust.

or Ref.

Date Su bj.

June 14, 1977 l

ERRATA - Report BAW-1437 I

ln,.i....,.........................w.....i,.

Please make the changes described below in your copy of BAW-1437, " Analysis of Caasule OCII-C From Duke Power Company Oconee Nuclear 3tation, Unit 2 - RVMS Program."

Description Page y

3-1 Paragraph 2, line 2: Change SA502 to SA508.

Last Paragraph: Change to insert underlined words in place of those now in the text; should then read as follows:

All test specimens were machined from the 1/4-thickness location of the shell forging. Charpy V-notch and tensile specimens from the vessel ma-terial were oriented with their longitudinal axes parallel to the principal working direction of the forgings; the specimens were also otiented trans-verse to the principal working direction. Capsule OCII-C contained dosim-eter wires, described as follows:

C-19 Figure C-9: On the line labeled T 'DT, enter -20F.

On the line labeled RTNDT' "" *#

Correcting these errors by hand will climinate issuing a revision. Thank you.

j t

0

,- 1