U.S. NUCLE AR REGULATORY COMYtSSloN
- 3' 33' S-~ % 0412 C 'O' CERTIFICATE OF COMPLIANCE n== R 1 For Racicacave Yateriais Paczages c
1..i;
,e :f;mte Nur-eer 1.(t) 5364 3
USA /5364/B( )
Pagis No.1.(e) Totb
- o. Pages Revisi n No.
1.!c) *ackace identification No.
1.!d) i N L 88 :" VE _s LW TNs cartdierte is issued to satisfy Sec vons 173.333a,173.394.173.395. and 173.396 of the Ceoartment of Transportation w :sedous,
.d.$.$
a Materials Aegulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of H4 e- =-
Transportation Oangerous Cargoes Asquiations (46 CFR 146-149), as amended.
F--
2.S)
The pacxagirw; and corttents described in item 5 below, meets the safety standards set fcrth in Sucoart C of Titfe 10. Code of Faseral Aegulations. Part 71 " Packaging of Racicactive Materials for Transoort and Transportation of Racioactive Matenal Under
~
Cataan C.sncitaans.**
E
- 2. d 7bs certificata does not relieve the consagnor from complianca witn any requirement of the regulations of the U.s. Copertment of Transcuartztion or other acpicaole regulatory agencies, inducing tne government of any cuntry through or into whicn the package ] gr
"~{""
voit be trart4ll cried.
- 1 17Ms cartrficate is ismand on the basis of a safety analysts report of the package design er application-1M P somrud by (Name and address):
3.(b)
Tide and identification of report or apolication:
9l'2ll Neutron Pioducts Incorporated Neutron Products Incorporated application 22301 dt. Ephraim Road dated March 26, 1974, as supplemented.
"+
Dickerson, MD 20753 4-~
3.te)
=ce,,e so.
- 4. CONCITIONS Dis cartrfaczte is conditional upon the fulfilling of the re:tuirernents of Succart o of to CFR 71, as acoiicable, and the conditions specified in ' ac. E beiow.
c 5.
est coca of Packaging and Authorl2ed Contents. Model Numoer, Fissile Cass. Other Conditions, and
References:
.c.
(a) Packaging
,=.
(1-) Model No.: NPI-67-0442.
.=
.(2) Description The pac'kaging is a steel encased, lead shielding shipping cask of circular cross section.
The outer carbon steel shell is 7/8-inch thick, has a 30-inch 00 and is finned with 1/2-inch x 4-inch fins spaced on 3-inch centers,. The inner stainless steel shell is 1/4-
- =-
inch thick. A minimum 6-inch lead shield is provided on the sides and ends. The cask is comprised of two (2) axially connected sections which are chosen from four (4) different sections, described as follows:
SECTION LENGTH (inches)'
CAVITY CONFIGURATION
.7
~A 74 A 5-inch OD center tube surrounded by '
by 48, 1/2-inch 00 and 60, 3/4-inch
~
OD tubes within a 15-inch diameter central cavity. The space between the
',f tubes is filled with lead.
.. :=
a
_B 54 Same as Section A.
w C
31 A 15-inch diameter central cavity.
- 3 a
0 16 None.
a..
8006090 N g
]$;ez-CertificateNo.5364-RevisionNo. 3 - Docket No. 71-5364 G
5.
(t)(2)
Description (Cont'd)
~
The sections described abose are connected in pairs to form four (4) cask configurations.
The sections are connected by thirty-six (36),
~
2 r--
3/4-16 UNF studs equally spaced around 34-inch OD grooved flange rings which are welded to each section. An 0-ring or flat ring gasket provides a seal between the connected pairs which form the
- m.
cask configurations described below:
?.Q CONNECTED CASK CASK CAVITY WEIGHT MODE SECTIONS LENGTH (inches)
LENGTH (inches)
(pounds)
L:;..
I A and B 114 Su 30,000 II A and C 91 58 23,000 4;.
III B and 0 60 27 15,000 IV C and D 38 5
8,000 A steel encased, lead filled cover in Section A provides access to the cask cavity for Modes I and II. The cover is secured with twelve (12), 7/8-9UNC hex head bolts. A seal is provided by a 1/4-inch
=:
diameter by 16-1/2-inch ID 0-ring.
The cavity is filled with inert gas for shipment, and is provided with a relief valve set at 45 psig.
The cask is fitted with lifting sockets.
Section D, and the cover for Section A are fitted with lif ting lugs. A 1/2-inch thick steel pad is welded to the cask, and may be used for tie-down.
[.i (2) Drawings
' ii p
[li
_The packaging is constructed in accordance with the following t.E -
[J 0.G. Kelley Co. - Neutron Products, Inc. Drawings Nos. :
67-0442-1, F*
Rev. 8; 67-0442-2, Rev. 2; 67-0442-3, Rev. 7; 67-0442-4, Rev. 6; 67-0442-5, Rev. 2, 67-0442-6, Rev. 2; and 67-0442-7, Rev. O.
P 1
(b)
Contents i
(1) Type and form of material Ei".
Cobalt-60 meeting the requirements for special form materials
!G (10 CFR 571.4(o)).
8=.=.
(2) The maximum quantity of material per package Ex-filii....
RADI0 ACTIVITY INTERNAL HEAT
$f PACKAGING CURIES OF COBALT-60 (kw)
T.*
n l
C_'
Mode I 600,000 9.4 Mode II 400,000 6.2 Mode III 200,000 3.1
.c =
Mode IV 120.000 1.9
\\;g; x-
.2 9
t Page 3 - Certificate No. 5364 - Revision No. 3 - Docket No. 71-S364 6.
The cavity shall be dried, purged and filled with an inert atmosphere prior to shipment.
7.
The contents shall be held within the cavity so as to fix its position during transport.
8.
The lifting lugs on Section D and the cover of Section A shall be covered, locked or removed to prevent their use for lifting or tiedown of the package during transport.
~
The package authorized by this certificate is hereby approved for use 9.
under the general license provisions of 10 CFR 571.12(b).
10.
Expiration date:
May 31,1984.
REFERENCES Neutron Products, Incorporated application dated March 26, 1974.
Supplement dated May 12, 1980.
FOR THE U. S. NUCLEAR REGULATORY COMMISSION
{,f Transportati n Certification Branch Charles E. MacDonald, Chief j
Division of Fuel Cycle and Material Safety Date: MAY ?.? 7c00 e