ML19312C119

From kanterella
Jump to navigation Jump to search
Responds to 740731 Bulletin 74-08.ITE Molded Case Circuit Breakers,Type HE-3,not Utilized in Safety Sys
ML19312C119
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 08/19/1974
From: Thies A
DUKE POWER CO.
To: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-74-08, IEB-74-8, NUDOCS 7912040545
Download: ML19312C119 (2)


Text

l

, g

]UICE POWER COMPANY

~

-d Powen Durr.9two j

i 4cc Sourir Ciruacir STnznT, Gn..ar4TTE, N. C. osaoi A. C. Tn rus P. O. Box 2 70 s a..o. v.c t p c.ec.,

%oovetaan ano Tes=swess on I

August 19, 1974 t

Mr. Norman C. Moseley, Director j

Directorate of Regulatory Operations U. S. Atomic Energy Commission i

Region II - Suite 818 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Re: RO:II:NCM 50-269, 50-270, 50-287

'~

Dear Mr. Moseley:

In response to your letter of July 31, 1974, which transmitted Directorate of Regulatory Operations' Bulletin No. 74-8, we have reviewed the safety systems at Oconee Nuclear Station as requested..There are no ITE Molded Case Circui.t Breakers, Type HE-3, utilized in these systems.

Very truly yours,

[, 'kbE*-

A. C. Thies ACT:vr

-me

)

s' s.

AllG 2 41974 Letter from Duke Pouer Corrpany, A O. Thies, d ated August 19, 1974 269, 50-27,0, and 50-287 R0a 74-8 l

l DISTRIBUTION:

H D. Tnornourg RO:Iiq (4) l Directorate of Licensing (4)

DR Central Files John Rizzo, 00E FDR Local PDR NSIC OIS, OR T

e T

4 e

e

-