_.

AEC D RIBUTION FOR PART 50 DOCKET MA 'tIAL 8723 (TEMPORARY FORM)

CONTROL NO:

FILE:

i n

FROM:

DATE OF DOC DATE REC'D LTR MEMO RPT OTHER Duke Power Company Charlotte, North Carolina 28201 12-3-73 I 12-7-73 x

A. C. Thies TO:

ORIG CC OTHER SENT AEC PDR X

A. Giambuss 3 sir ed SENT LOCAL PDR X

CLASS UNCLASS PROP INFO tvT NO CYS REC'D KET NO:

XXX XXXXX 3

50-269 50-270 DESCRIPTION:

ENCLOSURES:

Ltr notarized 12-3-73 requesting modifications i

ACKNOWLEDGEp of Tech Specs 3.5.2.5 to auth operations at 9 2 7. powe r....

DO NOT REMOVE PLANT NAME:

Oconee Units 1 & 2

~

FOR ACTION /INFORMATION 12-8-73 fod BUTLER (L)

/$CWENCER'L)

ZIDIANN(L)

REGAN(E)

W/ Copies W/ 6 Copies W/ Copies W/ Copies CLARK (L)

STOLZ(L)

DICKER (E) l W/ Copies W/ Copies W/ Copies W/ Copies I

GOLLEn(L)

VASSALLO(L)

KNIGHION(E)

W/ Copies W/ Copies W/ Copies W/ Copies a

KNIEL(L)

SCHDiEL(L)

YOUNGBLOOD(E)

W/ Copies W/ Copies W/ Copies W/ Copies l

l g.

INTERNAL DISTRIBUTION l

' C 6 REG FILF J TECH REVIEW DENTON A/T IND l

/AEC PDR HENDRIE GRIMES LIC ASST BRAIIMAN

',0GC, ROCM P-506A SCHROEDER GAMMILL DIGGS (L)

SALTZMAN A IZING/ STAFF MACCARY KASTNER GEARIN (L)

B. HURT CASE KNIGHT BALLARD

,,60ULBOURNE (L)

PMNS GIAMBUSSO PAWLICKI SPANGLER LEE (L)

MCDONALD BOYD SHA0 MAIGRET (L)

"DUBE MOORE (L)(WR)

STELLO ENVIRO SERVICE (L)

A EYOUNG(L)(PWR)

HOUSTON MULLER SHEPPARD (E)

INFO SKOVHOLT (L)

NOVAK DICKER SMITH (L)

C. MILES P. COLLINS ROSS KNIGHTON TEETS (L) g A. CABELL IPPOLITO YOUNGBLCOD WADE (E)

REG OPR TEDESCO REGAN WILLIAMS (E)

  1. FILE & REGION (2)

LONG PROJECT LDR WILSON (L)

MORRIS LAINAS f,, j, N STEELE BENAROYA HARLESS VOLIMER EXTERNAL DISTRI3UTION

. i - LOCAL PDR Wal'alla, s. G.

n DTIE(ABERNATHY)

(1)(2)(10) NATIONAL LAB'S 1-PDR-SAN /LA/NY A - NSIC(DUCHANAN) 1-ASLBP(E/W Bldg,Rm 529) 1-GERALD LELLOUCHE 1 - ASLB(YORE /SAYRE/

1-W. PENNINGTON, Rm E-201 GT BROOKHAVEN NAT. LAB WOODARD/"H" ST.

1-CONSULTANT'S 1-AGMED(Ruth Guss=an)I y16 - CYS ACRS M Sent 12-8-73 to NEUMARK/BLUME/AGBABIAN RM-B-127, GT.

E. Gou1 bourne for 1-GERALD ULRIKSON...ORNL l-RD.. MULLER..F-309 G9 Dist.

Durz Powza COMPANY Powum BuzLonto ans SouTu Catracu GmAnzarrx, N. C. assos g\\

'I O 5N (A

A. c. rouas N

r.o.non sne se. ion vice p.e. ion r 8,-/

gc#

y e over..... v....

u U

m cy.

gg73 7 5 Regulatory December 3, 1973 M 97C7 m

'A W.

e n^

n g

- //[ "

D A

S 3

cc h / g [

ff Mr. Angelo Giambusso sg Deputy Director for Reactor Projects y

3 Directorate of Licensing k'

Office of Regulation U. S. Atomic Energy Commission e#

g Washington, D. C.

20545 it, Re: Oconee Units 1 2

Docket Nos.

2 d 50-270

Dear Mr. Giambusso:

My letter of November 30, 1973 requested certain modifications of Technical Specifications 3.5.2.4 and 3.5.2.5.

We discussed these proposed changes with members of your staff in a meeting in Bethesda, Maryland on November 1, 1973 and in a conference telephone conversation on November 30, 1973, and they have indicated that more time will be required to complete their review of these. proposed changes.

On November 23, 1973, a Unit 1 control rod drive stator failed causing a Group 7 rod to drop into the core.

Other Group 7 rods were inserted into the core to prevent an asymmetric power distribution. Operation with one dropped rod is permitted under Technical Specification 3.5.2.2; however, in order to meet the control rod withdrawal limits, specified in Technical Specification 3.5.2.5(c), Unit 1 must be operated at less than 80 percent rated power.

The requested modifications of Technical Specification 3.5.2.5 would permit operation up to 92 percent power.

The additional power generated by Oconee Unit 1, which this technical specification change would permit, could represe.nt a saving of fossil fuel equivalent to 7200 barrels of fuel oil per day.

In view of the possible saving of substantial amounts of fuel oil, it is requested that Technical Specification 3.5.2.5(c) be waived for oconee Unit 1.

If such waiver is granted, Duke Power Company will impose the following conditions on the operation of Oconee Unit 1:

(1) Reactor power will be maintained below 92 percent full rated power.

(2) Quadrant tilt will not exceed 4 percent.

(3) Other specifications in Technical Specification 3.5.2 will be met.

,~ (3 D 1 s

O

/

t Mr. Angelo Giambusso Page 2 December 3, 1973 (4) The reactor will be operated at 80 percent power for at least 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> before proceeding to 92 percent power.

(5) Power maps will be taken every four hours during steady-state operation and immediately following power transients greater than 10 percent rated power and once every two hours for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the transient to assure that LOCA kilowatts per foot limits are not being exceeded.

The incore instrumentation will be used for the power mapping.

If the LOCA limit is exceeded, power level will be reduced to below 80 percent power.

It is requested that this waiver be in effect until December 30, 1973, or the Oconee Unit 1 Technical Specification 3.5.2 revision now under review is approved by the Atomic Energy Commission or the reactor is shut down to repair the inoperable rod, whichever occurs first.

Very truly yours, 3

A. C. Thies ACT:vr l

i 9

e

'Mr. Angelo Giambusso Page 3 December 3, 1973 A. C. THIES, being duly sworn, states that he is Senior Vice President of Duke Power Company; that he is authorized on the part of said company to sign and file with the Atomic Energy Commission tcis request for waiver of the Oconee Nuclear Station Technical Specificat.lons, Appendix A to Facility Operating Licenses DPR-38 and DPR-47; and that all statements and matters set forth therein are true and correct to the best of his knowledge.

A. C. Thies, Senior Vice President ATTEST:

A... &

[~

Dorothea B. Stroupe Assistant Secretary Subscribed and sworn to before me this 3rd day of December, 1973.

G n n L. /L A Notary Public My Commission Expires:

Y%> 10, / 9 '7 'T

/

b r

\\

l

-