- y e
v DISTRIBUTION:
May 16,1977 Docket File-NRC PDR L PDR GVissing ORB #4 Rdg 1cc..n
.o.
n'"
VStello BGrier KRGoller Attorney, OELD OI&E (3)
RReid
]ropciitar; Edison Company GZwetzig
,u i.:
- r.
C..rncid RIngram
'.' ice ?rcsi<ient - Ceneration DEisenhut P. O. Cox CJ2 TBAbernathy badir.g, pennsylvania 19C03 JRBuchanan ACRS (16)
,,entl encn :
t Gray File 6y latter dated October 24, 1975. you reported on a ccnditicn which sonetires occurred at Three ' tile Island Unit 'Io.1 (T".I-1) where the terperature within the reactor building would exce?d the 110 F sustained tornerature assur:ed in the FSAR.
Specifically you recorted that r/erage terreraturcs ap? roaching 130 F were experienced abcve elevation 320 fcet, and 110 F to 120 F were experienced below elevation 320 feet
': nan the outside wet bulb tcrperature was greater than abcut 7?F.
!n ycur letter you discussed the cases for your conclusion that those observed temperatures were acceptable, and comitted yourselves to corrective action to minimize their occurrence and to linit the tercer-atures in the reactor building to the observed values.
l'e have reviewed the information you have supplied in regard to this
- r. attar, including that contained in your letter of March 25, 1977, and have concluded that the observed tenperatures are acceptable. The control of the tancerature in the containment, hov.cVer. is irportant to safety since, i' not controlled it could adversely affect the' structural intecrity of the centainment and/or the operability of safety-N related ccaponents.
iccordingly, you are requested to sutnit nrocosed technical scecifications defining the finiting conditions for operation relative to teperatures in the containrent, the supporting bases for such liaits, and a::propriate surveillance and action requirements.
' rodel for such technical specifications is given in the decurent, " Standard Technical Scecifications for Babcock & Wilcox Pressuriz2d t!ater Reactors." NUREG- 0103, Revisica 1.
I j-i THIS40CUMENT-CONTAINS POOR QUAUTY PAGES 7 910 290 $60 I
O
-O e
i i
trm ali bn C.lison '.'cevu f
f 4
j h t re ;usstsei.tMr ycur ::r:posM tec::nical specifications relatiac to r.peratur?.linits within containmnt *:e su!mittori tsithin 3: brs of rcceipt of this letter.
Sincerely, 4
.?
l.
i
. Robert '!. P.eid, Chief i
Operating Recctors Granch N Divhion of Operating P.aactors i
l cc:
Sc3 next page 3
4 1
4 4
i i
I i
t 1
i 1
1 ii i
ii 1
i; t
1 1
1 4
1 1-I f
I i
c elb l a
i (RB#h00R
...,C4)RB#4 : 00R l
o...e
-z.~.-
a...
v-GZwetzig:rm 1tReid 3
5/ #/77
- 5// w'/77 3.es i
' foran AIC 313 (Rev. 9-95) AZCM 0240
. J w. a. sov:g= any..iny ms orrics: ser..sa se, a
i i-,--,,,.~,.,+--.~-,-n...~L..
-.,,.,,-,--,i,------
-..,,.,an.v,-~,,.
,,- ---, -,,.,;.,,,. -, r v e;
C (3
q.)
\\
r.
Metropolitan Edison Company cc:
G. F. Trowbridge, Esq.
Shaw, Pittman, Potts, & Trowbridge 1800 M Street, fl. W.
Washington, D. C.
20036 GPU Service Corporation Richard H. Heward, Project Manager Thomas M. Cricains, Jr., Safety and Licensing Manager 260 Cherry Hill Road Parsippany, Mew Jersey 07054 Pennsylvania Electric Company Mr. R. W. Conrad Vice President, Generation 1001 Broad Street Johnstown, Pennsylvania 15907 Mr. Weldon B. Arehart, Chairnan Board of Supervisors of Londonderry Township RFD #1, Geyers Church Road Middletown, Pennsylvania 17057 Miss itary V. Southard, Chairman Citizens for a Safe Environnent t
P. O. Box 405 Harrisburg, Pennsylvania 17108 Gcvernment Publications Section State Library of Pennsylvania Box 1601 (Education Building) i Harrisburg, Pennsylvania 17126 ang c
a i
l t
.