MONTHYEARML24024A0342024-01-22022 January 2024 Us Dept. of Transportation, Maritime Administration - Submittal of Decommissioning Quality Assurance Plan, Revision 4 ML24022A1532024-01-18018 January 2024 Us Dept. of Transportation, Maritime Admin, Submittal of Decommissioning Quality Assurance Plan, Revision 4 IR 05000238/20230012023-09-0606 September 2023 U.S. Department of Transportation, N.S. Savannah - NRC Inspection Report 05000238/2023001 ML23094A1282023-03-29029 March 2023 Us Dept. of Transportation, Maritime Admin - Submittal of Decommissioning Funds Status Report for Calendar Year (Cy) 2022 ML23062A1772023-02-28028 February 2023 Us Dept. of Transportation, Maritime Admin., Submittal of Annual Report for CY2022, Revision 0 ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities IR 05000238/20220012023-01-10010 January 2023 U.S. Department of Transportation, N.S. Savannah - NRC Inspection Report No. 05000238/2022001 Dated January 10, 2023 ML22265A0762022-09-26026 September 2022 U.S. Department of Transportation Maritime Administration, N.S. Savannah - Nrc'S Analysis of Marad'S Decommissioning Funding Status Report ML22105A1142022-04-18018 April 2022 U.S. Department of Transportation Maritime Administration, Nuclear Ship Savannah - Change in U.S. Nuclear Regulatory Commission Project Management ML22062B0382022-02-28028 February 2022 Us Dept of Transportation, Maritime Admin., Submittal of Annual Report for CY202 L, Revision 0 ML21258A2952021-09-14014 September 2021 Revised License Termination Schedule - Docket No. 50-238; License No. NS-1; N.S. Savannah IR 05000238/20210012021-08-10010 August 2021 U.S. Department of Transportation, N.S. Savannah - NRC Inspection Report 05000238/2021001 ML21211A5392021-07-23023 July 2021 Us Dept. of Transportation, Maritime Admin., Submittal of Updated Final Safety Analysis Report, Revision 12 and Decommissioning Quality Assurance Plan, Revision 3 ML21127A1572021-05-0303 May 2021 U.S. Dept. of Transportation, Maritime Administration - Submittal of Updated Final Safety Analysis Report, Revision 11 ML21126A2122021-04-30030 April 2021 U.S. Department of Transportation, Maritime Administration - Notice of Management Contract Award ML21099A1882021-03-31031 March 2021 Submittal of Decommissioning Funds Status Report for Calendar Year (Cy) 2020 ML21099A1102021-03-31031 March 2021 Us Dept. of Transportation, Submittal of Annual Radiological Environmental Monitoring and Radioactive Effluent Release Reports for CY2020, Revision 0 ML21067A6652021-03-18018 March 2021 Ns Savannah LAR 18, Change to Ship Draft Monitoring Method, and Deletion of Redundant Tech Specs ML21063A2392021-02-26026 February 2021 Us Dept. of Transportation, Maritime Admin, Annual Report for CY2020, Revision 0 IR 05000238/20200012020-12-0202 December 2020 NRC Inspection Report No. 05000238/2020001, U.S. Department of Transportation, N.S. Savannah, Baltimore, Maryland ML20255A0842020-09-0404 September 2020 Us Dept. of Transportation, Maritime Admin: Administrative Changes to Technical Specifications - License Amendment Request No. LAR 2020-01 ML20136A3452020-05-0707 May 2020 Submittal of Annual Radiological Environmental Monitoring and Radioactive Effluent Release Reports for CY2019, Revision 0 ML20122A0582020-04-24024 April 2020 Us Dept of Transportation, Maritime Admin., Submittal of Decommissioning Funds Status Report for Calendar Year (Cy) 2019 ML20059K9452020-02-26026 February 2020 U.S. Dept. of Transportation, Maritime Admin. - Annual Report for CY2019, Revision 0 IR 05000238/20190022020-01-0808 January 2020 NRC Inspection Report No. 05000238/2019002, U.S. Department of Transportation, N.S. Savannah, Baltimore, Maryland ML19310F0012019-11-20020 November 2019 Ns Savannah, Correction to Amendment 17 Technical Specifications ML19192A1672019-07-0909 July 2019 Status of Potential Post-Shutdown Decommissioning Activities Report (PSDAR) Meeting in Philadelphia, PA ML19085A4822019-06-11011 June 2019 Nuclear Ship Savannah - Issuance of Amendment 17 to Revise the Technical Specifications to Revise the Radioactive Effluent Controls and Make an Administrative Change ML19091A0862019-03-28028 March 2019 U.S. Department of Transportation Maritime Administration Submittal of Decommissioning Funds Status Report for CY2018 IR 05000238/20190012019-03-28028 March 2019 U.S. Department of Transportation, N.S. Savannah, Baltimore, Maryland, NRC Inspection Report 05000238/2019001 ML19060A0612019-02-27027 February 2019 U.S. Department of Transportation, Maritime Administration - Annual Report for CY2018, Revision 0 ML18325A1472018-09-0909 September 2018 Us Dept. of Transportation (DOT) - License Amendment Request No. LAR 2018-02 ML18173A1282018-06-19019 June 2018 United States Maritime Administration License Amendment Request No. LAR 2018-02 Technical Specification Changes to Revise Section 2.0, Radioactive Releases ML18109A5782018-06-12012 June 2018 Letter to Koehler, Nuclear Ship Savannah - Issuance of Amendment 16 to Revise the Technical Specifications to Establish Controls for All Accesses to the Containment Vessel in Support of Two Structural Modifications ML18135A0892018-05-17017 May 2018 Letter: Response to Maritime Administration Invitation to Consult on Decommissioning and License Termination for Nuclear Ship Savannah ML18081A1342018-04-23023 April 2018 Letter to Koehler, Regarding Nuclear Ship Savannah - Issuance of Amendment 15 to Revise the License to Allow Dismantlement and Disposal ML18114A1082018-04-20020 April 2018 Us Dept of Transportation, Maritime Admin. - Section 106 Consultation for the National Historic Landmark Nuclear Ship Savannah Decommissioning Project ML18093A3772018-03-30030 March 2018 Us Dept. of Transportation, Maritime Admin., License Amendment Request - Technical Specification Changes to Include the D Deck Containment Vessel Door and Cold Chemistry Laboratory Door ML18088A1602018-03-26026 March 2018 Us Dept of Transportation, Maritime Admin. - Submittal of Decommissioning Funds Status Report for Calendar Year (Cy) 2017 ML18058A7462018-02-23023 February 2018 Us Dept. of Transportation, Maritime Administration - Annual Report for CY2017, Revision 0 IR 05000238/20170012018-01-0808 January 2018 NRC Inspection Report No. 05000238/2017001, U.S. Department of Transportation, N.S. Savannah, Baltimore, Maryland ML17307A0362017-10-31031 October 2017 License and Technical Specification Changes to Allow Dismantlement and Disposal, License Amendment Request No. LAR 2017-01 ML17153A0332017-05-30030 May 2017 Availability of Funds for Decommissioning ML17094A7282017-03-31031 March 2017 N.S. Savannah, Submittal of Decommissioning Funds Status Report for Calendar Year (Cy) 2016 ML16095A2342016-03-31031 March 2016 N.S. Savannah, Submittal of Decommissioning Funds Status Report for 2015 ML16062A1722016-02-29029 February 2016 Maritime Administration - Transmittal of Annual Report for Calendar Year 2015, Revision 0 ML14290A4862015-06-0303 June 2015 Y020140127 - Withdrawal of Order EA-05-007, Order Imposing Additional Security Measures ML15124A7572015-05-0101 May 2015 U.S. Dept. of Transportation, Maritime Administration - Submittal of Final Safety Analysis Report, Revision Viii ML15118A5402015-04-23023 April 2015 Us Dept of Transportation, Maritime Administration (Marad) - Submittal of Decommissioning Funds Status Report for Cy 2014 ML15063A5782015-02-28028 February 2015 Us Dept. of Transportation, Maritime Administration (Marad), Submittal of Annual Report for CY2014, Revision 0 2024-01-22
[Table view] Category:Technical Specifications
MONTHYEARML21067A6652021-03-18018 March 2021 Ns Savannah LAR 18, Change to Ship Draft Monitoring Method, and Deletion of Redundant Tech Specs ML19310F0012019-11-20020 November 2019 Ns Savannah, Correction to Amendment 17 Technical Specifications ML18109A5782018-06-12012 June 2018 Letter to Koehler, Nuclear Ship Savannah - Issuance of Amendment 16 to Revise the Technical Specifications to Establish Controls for All Accesses to the Containment Vessel in Support of Two Structural Modifications ML18081A1342018-04-23023 April 2018 Letter to Koehler, Regarding Nuclear Ship Savannah - Issuance of Amendment 15 to Revise the License to Allow Dismantlement and Disposal ML0702307182007-01-31031 January 2007 Erhard W. Koehler Ltr Issuance of Amendment No. 13 (License Amendment Request No. 2006-01) for Ns Savannah (Docket No. 50-238, License No. NS-1) ML0622705872006-08-0707 August 2006 License Amendment Request No. 2006-01, Technical Specification Changes to Support Pre-Decommissioning Activities 2021-03-18
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 20, 2019 Mr. Erhard W. Koehler Senior Technical Advisor, N.S. Savannah U.S. Department of Transportation Maritime Administration (MAR-640.2) 1200 New Jersey Avenue, SE W25-209/212 Washington, DC 20590-0001
SUBJECT:
NUCLEAR SHIP SAVANNAH - CORRECTION OF TYPOGRAPHICAL ERROR IN AMENDMENT 17 OF THE TECHNICAL SPECIFICATIONS
Dear Mr. Koehler:
This letter corrects a typographical error introduced into the Technical Specifications (TS) for the Nuclear Ship SAVANNAH (NSS). License number NS-1, during U.S. Nuclear Regulatory Commission (NRC) approval of an Amendment revising the NSS TS.
On June 18, 2018, (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML18109A578) NRC approved Amendment 16 to the NSS TS to modify section 3.7.1 to establish controls for all accesses to the Containment Vessel (CV) in support of two structural modifications to provide restored access via the C Deck and new access via the D Deck. These changes were requested, noticed and evaluated before being approved on June 18, 2018. The structural modifications have since been completed and access controls provided in accordance with the approved revised TS.
Subsequently, on June 11, 2019, (ADAMS Accession No. ML19085A482) NRC approved Amendment 17 of the NSS TS to revise the radioactive effluent controls to incorporate a Process Control Program, an Offsite Dose Calculation Manual, a Radioactive Effluent Controls Program and a Radiological Environmental Monitoring Program. As part of this approval action, the TS were reissued in their entirety for improved readability. However, when the TS was reissued, the TS erroneously excluded the approved changes made in Amendment 16. This exclusion was not requested, noticed or reviewed as part of Amendment 17. Therefore, this error meets criteria for amendment correction as a typographical error as described in the Office of Nuclear Reactor (NRR) Office Instruction LIC-101, Revision 4 (ADAMS Accession No. ML113200053), and the criteria in the January 16, 1997 NRR memo on License Amendment Corrections of Technical Specifications (ADAMS ML103260096).
The NRC staff has prepared and reviewed corrected pages to Amendment 17 of the NS-1 TS, which are provided in Enclosure 1.
E. Koehler In accordance with the Title 10 Code of Federal Regulation (10 CFR) 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
If you have any questions, please contact me at 301-415-3017, or via e-mail at theodore.smith@nrc.gov.
Sincerely, Theodore B. Smith, Project Manager Reactor Decommissioning Branch Division of Decommissioning, Uranium Recovery and Waste Programs Office of Nuclear Material Safety and Safeguards Docket Nos. 50-238
Enclosure:
Corrected Pages 9 and 10 of Amendment No. 17 to the NS-1 Technical Specifications
ML19310F001
- Via Email OFFICE DUWP DUWP DUWP OGC/NLO DUWP DUWP NAME TSmith CHolston* BWatson* AGendelman* BWatson* TSmith*
DATE 11/5/2019 11/6/2019 11/7/2019 11/19/2019 11/20/2019 11/20/2019 ENCLOSURE CORRECTED PAGES 9 AND 10 OF TECHNICAL SPECFICATIONS AMENDMENT NO. 17 TO LICENSE NO. NS-1 UNITED STATES MARITIME ADMINISTRATION NUCLEAR SHIP SAVANNAH DOCKET NO. 50-238
CORRECTION TO LICENSE AMENDMENT NO. 17 TO FACILITY OPERATING LICENSE NO. NS-1 DOCKET NO. 50-238 Replace the following page of the Technical Specifications with the attached revised page.
Revised pages are identified by amendment number and contains marginal lines indicating the area of change.
Technical Specifications Remove Insert 9-10 9-10
3.6.4 These reviews may be accomplished and concurred with by members of the Committee without a formal meeting.
3.6.5 The Committee shall be convened by the Chairman and shall meet annually to review and discuss events of the preceding period. The Committee will meet when necessary to review evaluations of Reportable Events per Technical Specification 3.4.3.1.
3.6.6 Written minutes of all meetings shall be prepared and distributed to all Committee members.
3.7 Ship Access Control and Surveillance Applicability Applies to routine access control and surveillance of the ship.
Objective To prevent unauthorized entry into Radiological Controlled Areas by manning or securing their entrances and to determine change in radiation levels or integrity of the ship. An entrance is secured by bolting, welding, locking via a chain and/or hasp, or preventing access via an equivalent method.
3.7.1 Access Control 3.7.1.1 All containment vessel entrances shall be either manned or secured.
3.7.1.2 All Radiological Controlled Areas entrances will be manned or secured.
3.7.1.3 All Radiological Controlled Area entrances will be posted with appropriate caution and warning signs.
3.7.1.4 All entrances to the ship not in use will be secured at all times.
3.7.1.5 The B Deck Reactor Compartment entrance at Frame 122, the C Deck Door to the Cold Chemistry Laboratory and the D Deck Containment Vessel Door shall be either:
a) Manned or b) Locked from the outside and fitted with an intrusion alarm that alerts a security monitoring station.
3.7.1.6 MARAD trained personnel will patrol the vessel at least once during a twenty-four (24) hour period.
3.7.1.7 Deviations from the above access control conditions will be in accordance with appropriate parts of Section 3 of these Technical Specifications, Administrative Controls.
3.7.2 Surveillance 3.7.2.1 Periodically and at least once a quarter, MARAD's designated personnel will inspect the Radiological Controlled Area entrances to verify they are properly secured and test the intrusion alarm in Technical Specification 3.7.1.5.
Amendment 17 (Corrected)
November 20, 2019
3.7.2.2 Radiological surveys of the ship will be performed at least annually and as necessary to support ship activities in accordance with 10 CFR 20.
3.7.2.3 DELETED.
3.7.2.4 DELETED.
3.7.3 Vessel and System Maintenance 3.7.3.1 Two draft level stripes will be painted fore and aft (at the draft marks), one will be just above the water level and the upper stripe will be one foot above the lower. These will be observed daily to check if the draft has increased. Both stripes must always be visible. If the lower stripe is not visible, the ship shall be surveyed and the water leakage located. The source of leakage will be determined, the ship pumped out, and repairs made as may be required, including dry-docking if determined necessary, in order to assure that the integrity of the hull is maintained.
3.7.3.2 A cathodic protection system will be provided and properly maintained to protect the underwater areas of the vessel's hull to minimize corrosion damage to the hull.
3.7.3.3 An underwater inspection of the hull will be conducted at least every four (4) years. The vessel will be dry-docked if the inspection determines that such action is necessary due to localized severe pitting, underwater plate thinning in excess of 40 percent, or other damage that would require corrective action and/or removal of the vessel to an off-site ship repair facility.
3.7.3.4 An inspection will be conducted at least annually by MARAD's designated personnel to determine any degradation of the primary, auxiliary and secondary systems.
Amendment 17 (Corrected)
November 20, 2019