Forwards First Interim Deficiency Rept Re Design Criteria for Secondary Side Pipe Breaks.Next Rept Will Be Submitted by 800904
Date released: 11/20/2019 Download: ML19310A436


First Interim Deficiency Rept Re Design Criteria for Secondary Side Pipe Breaks.Criteria Does Not Provide for Propagation of Main Steam Cracks to Other Lines.Evaluation Underway of Pipe Rupture Interaction
ML19310A439
Person / Time
Site: Sequoyah 
Issue date: 06/11/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19310A439 (1)
Forwards First Interim Deficiency Rept Re Design Criteria for Secondary Side Pipe Breaks.Next Rept Will Be Submitted by 800904
ML19310A435
Person / Time
Site: Sequoyah 
Issue date: 06/11/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19310A435 (1)