ML19310A435

From kanterella
Jump to navigation Jump to search
Forwards First Interim Deficiency Rept Re Design Criteria for Secondary Side Pipe Breaks.Next Rept Will Be Submitted by 800904
ML19310A435
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 06/11/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19310A436 List:
References
NUDOCS 8006170545
Download: ML19310A435 (1)


Text

_ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _

TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II June 11, 1980 Mr. James. O'Reilly, Director Office of pection and Enforcement U.S. Nuclear gulatory Commission Region II - Su a 3100 101 Marietta St et Atlanta, Georgia 0303

Dear Mr. O'Reilly:

SEQUOYAh NUCLEAR PIANT UNIT 2 - DESIGN CRITERIA FOR SECONDARY SIDE PIPE BREAKS - NCR SQN CEB 8012 - FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-01E Inspector R. W. Wright on May 16, 1980, in accordance with 10 CFR 50.55(e).

Enclosed is our first interim report. We expect to submit our next report by September 4, 1980.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 857-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY

)

L. M. Mills, Manager Nuclear Regulation and Safety

)

1 Enclosure

/

[

cc Mr. Victor Stello, Jr., Director (Enclosure) /

l Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 h

sih 5

~_,e..._-..,,,

8006170 646

..