ML19309H901
| ML19309H901 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 05/15/1980 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| Shared Package | |
| ML19309H902 | List: |
| References | |
| NCR-SQN-CEB-800, NUDOCS 8005200637 | |
| Download: ML19309H901 (1) | |
Text
'@**
{ gj F
f,, 7 dO 6;
$ d.I j 8 005200 Q TENNESSEE VALLEY AUTHORITY cHATTANOCGA. TENNESSEE 374o1 400 Chestnut Street Tower II May 15, 1980 Mr. James. O'Reilly, Director Office of In ection and Laforcezaent U.S. Nuclear lacory Connaission Region II - Suite ' 100 101 Marietta Street Atlanta, Georgia 303
Dear Mr. O'Reilly:
SEQUOYAH NUCLEAR PLANT UNIT 2 - ERROR 1h ANALYSIS OF WO-INCH CONTAIMIENT SPdAY TEST LINES - hCR Syh CLB 8007 - FINAL REPORT The subject deficiency was initially reported to NRC-0IL Inspector C. R. McFarland on April 13, 1980, in accordance with 10 CFR 50.55(e).
Enclosed is our final report.
If you have any questions concerning this matter, please get in touch witn D. L. Lambert at FTS 854-2561.
i Very truly yours, i
TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure Mr.VictorStallo,Jr., Director (Enclosure)/
cc Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Wasnington, DC 20555
\\
l I
l An Ecual Occortun.ty Employer
.m1