i Jersey Central Power & Light Cm pany i
j Oyster Creek Nuclear Generating Station
)
Semi-Annual Report No. 79-2 Provisional Operating License No.DPR -16 i
i j
Radioactive Effluent Releases i
1 July 1979 through Decenber 1979
- l 4
Addendum i
~
j..
i i
i t
i I.
l t
i I
i e
a t
1
(
i I
e l
[:
III. DNIRCtMNTAL bONI70 RING The environmental nonitoring program was conducted during the reporting period in accordance with Technical Specification 4.6.B.3.
% e program included five general types of nonitoring.
These were (1) atnespheric radiation, (2) fallout, (3) domestic water, (4) surface water, and (5) nurine life. This nonitoring was acconplished by analyzing film badges for exposure and air particulate filters, rain water, vegetation, soil, crops, well water, surface water, silt, and clams for radioactivity.
We analyses results from these samples are found on the forthcoming tables. The tine period covered by this nonitoring extended from Juna 1979 through Novenber 1979 instead of July 1979 through Decenber 1979, due to normal delay in sanple analysis and reporting by the vendor. We sanpling locations are listed in Table III-A and are depicted in Figure III-1.
l.
Atnespheric Radiation nonitoring results, consisting of radiogas (film badges) and air particulate radioactivity measurements, are listed in Tables III-B, III-C, III-D, III-E, III-H, and Table III-J.
These tables cover the collection period from June 1979 through November 1979, with the exception of Table III-B which includes collection dates from June 1979 through August 1979 and Table III-C, which covers collection dates from Septenber 1979 through November 1979.
Included in Table III-D, in addition to the indicator nonitoring stations 2 through 17, are stations 1 and T1, which are located on site at the noteorological tower, and three background stations which are located at Allenhurst (A), Cookstown (C),'and Hannonton (H), New Jersey.
During the reporting period, several special programs were conducted and are listed below.
A.
TID evaluation - This program has continued intact since the last period on a nonthly basis. All exposures for this reporting period are seen in Table III-F.
B.
Isotopic analyses were perforned on all air particulate filters. The results can be found in Table III-H.
C.
Iodine 131 analysos were run on all the charcoal filters.
The results are shown in 7hble III-G.
III-l
2.
Fallout nonitoring, consisting of rainwater radioactivity neasure-nents, is listed in Tables III-B, III-C and Table III-E.
Background rainwater from stations A, C and H results are in Table III-J.
3.
Donestic Mter nonitoring, consisting of well water sanple analyses, is listed in Tables III-B, III-C, and III-E.
4.
Surface Water nonitoring, consisting of water and silt analyses from Barnegat Bay, Forked River, and Oyster Creek, is listed in Tables III-B, III-C, and III-E.
Se background station for surface water and silt is station number 31 and these results can be seen in Table III-J.
Isotopic analyses were perforned on the silt sanples from the bay and discharge canal. Se results can be seen in Table III-K.
5.
Marine Life nonitoring consisting of clam sanples, is listed in Table III-B, III-C & III-E.
%e background station results are listed in Table III-J.
6.
In addition to these analyses, vegetation, soil, and crop sanples were analyzed. he results are shown in Tables III-B, III-C, and III-E.
7.
Isotopic analyses were perforrnd on vegetable sanples.
%e results are listed in Table III-L.
Surface water sanple, SW-33-51, collected on July 23, 1979, was not analyzed for gross alpha dissolved activity by the analyses vendor. '1bchnician error was attributed as the cause.
To prevent reoccurrence, the analyses vendor has added a Sanple Coordinator to oversee laboratory operators.
A strontium-90 result on Food Products - Various sanple, FPV-28-75, was lost in analysis due to procedural error. Se sanple collection date was October 29, 1979. Iack of additional sarple prevented reanalysis. Se analysis loss was discovered subsequent to the end of the collection period.
Pertinent procedural review and personnel retraining by the analyses vendor was initiated to prevent reoccurrence.
r III-2