05000318/LER-1980-022-03, /03L-0:on 800412,charging Pump 23 Removed from Svc to Repair Weld on Suction Relief Valve.Leak Caused by Vibration Induced Metal Fatigue in Heat Affected Zone of Weld.Leak Repaired & Mods Approved for Charging Pumps

From kanterella
(Redirected from ML19309G445)
Jump to navigation Jump to search
/03L-0:on 800412,charging Pump 23 Removed from Svc to Repair Weld on Suction Relief Valve.Leak Caused by Vibration Induced Metal Fatigue in Heat Affected Zone of Weld.Leak Repaired & Mods Approved for Charging Pumps
ML19309G445
Person / Time
Site: Calvert Cliffs 
Issue date: 04/30/1980
From: Heibel R, Huseby D
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19309G442 List:
References
LER-80-022-03L, LER-80-22-3L, NUDOCS 8005060298
Download: ML19309G445 (1)


LER-1980-022, /03L-0:on 800412,charging Pump 23 Removed from Svc to Repair Weld on Suction Relief Valve.Leak Caused by Vibration Induced Metal Fatigue in Heat Affected Zone of Weld.Leak Repaired & Mods Approved for Charging Pumps
Event date:
Report date:
3181980022R03 - NRC Website

text

um LICENSEE EVENT REPORT 80050602.3 7 CONTROL BLOCK:

l l

l l

l (PLEASE PRINT OR TYPE ALL CE!UIEE3 INP!RMATION)

I M I D l C l C l N l 2 lgl150 l 0 l - l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@l 4 l 1 l 1 l 1 l 1 l@]

l l@

O i 9

UCENSEE CODE 14 uCENSE NUMsER 2S 26 UCENSE TYPE Jo 67 CAT SS 7

8 CON'T h",'fRU l L !@l 01510101013 l 118 l@l 014 l1 l21810 l@l014'I310 l A lo l@

o 5 7

8 80 41 DOCKET NUMSER es 69 EVENT DATE 74 76 REPORT DATE 80 FhENT DESCRIPTION AND PROBA8LE CONSEQUENCES O'o E I flumber 2_3 charging pucp was removed from service to repa!r t weld o's a 1

i suction relief valve. This charging pump was out of service from 1740 April 12.19801 0 2 l until 1800 April 15,1980. The other two redundant charoina oumos were noershle 0 4 I throughout this event. LER 78-49 (U-2) describes a similar event.

(T.S. 6.9.1.9) 1 O s I

O e l I

ITITl l l

O 8 l

r 8.

E OOE S SC E COMPONENT CODE SUS dE su E

I C l G I O LE_l@ L_.J @ l P I I l P l E l X l X l@ [H.j @ [1] @

O 9 7

8 9

10 31 12 13 18 19 20 LER EVENT YEAR RE ORT O 005 N

@ yy,/RO 18 lo I L--J l 01 212 l y

- 10131 LL 1 l-J Lo_J g

31 32 a

21 22 23 24 26 27 28 29 30 T

N AC ONP NT ME O HOURS 58 i FORPA 8.

SU L MAN P URER LB_J@lF_J@

LZ.j@

[.Z_j@

10101010l ltLJ@

LY_l@

LIJ@

Is lo 13 10l@

13 34 36 36 J7 40 44 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h IiiOi l This leak was caused bv vibratinn inancad mat =1 fatino. if +h ha2+ 2 rra,-+ A I

l zone of a weld. The leak has been repaired and a new system desion. modifving I

i i I

g i suction and discharge pipino of both units' charoina namns. has been annrnved l for modification. We anticipate comoletion of these modifications during the I

, 3 I

g iupcoming refueling outages.

STA

% POWER OTHER STATUS ISCO RY OlSCOVERY DESCRIPTION [E_J @ l1 10 10 l @l NA l

l Al@l Operator Observation l

i s A!TiviTY COErtuT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE l

NA l

l NA l

Li_1.5J LZ_1 @ LZ_J@uEs

,ERsON&Ex,0s NUMBER TYPE

DESCRIPTION

ITTil l O I O I O l@LIJ@l NA l

' ERsO~~EL%u'AEs DEsCRi,TiO~@

NuM8ER Lihl1010101@l NA l

80 7

8 9 11 12

^

'i',*E @Ms^c"R,T ON I

LIJ l

NA i 9 80 7

8 9 to E @ DESCRIPTION L2.J.O_j IS[S l

NA l

lllllllllllll{

68 69 80 3 i

F 3 9 10 R. P. Heibel/n. F stneohy PsoNef 7mi)?cO a7a,rge

{

NAME OF PREPARER