ML19309G148

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-01B, Environ Qualification of Class IE Equipment. Forwards Master List of All Equipment Required to Function Under Postulated Accident Conditions
ML19309G148
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 04/10/1980
From: Mathews E
WISCONSIN PUBLIC SERVICE CORP.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-79-01B, IEB-79-1B, NUDOCS 8005050036
Download: ML19309G148 (25)


Text

~

8

, M0.05obu0%

WISCONSIN PUBLIC SERVICE CORPORATION P.O. Box 1200, Green Bay, Wisconsin 54305 ,

April 10,1980 Mr. J. G. Keppler, Regional Director O.1 ice of Inspection 6 Enforcement Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Keppler:

Docket 50-305 Operating License DPR-43 IE Bulletin 79-OlB, Environmental Qualification of Class IE Equipment This letter contains certain information requasted by your office in the referenced bulletin pertinent to those items selected for the 45 day response.

We informed Mr. Hughes of your of fice of our intended action regarding this bulletin in a phone conversation on March 28, 1980.

Bulletin 79-OlB requested that we provide a " Master List" of all equipment required to func~ tion under postulated accident conditions. We have evaluated our plant systems to determine the equipment required to operate af ter an accident to bring the plant to a safe, shutdown condition, which may also be subject to a harsh environment. The attached documentation contains the results of our review of that equipment completed to date.

To the best of our knowledge the information contained in the attachments is true. Upon completion of our review an update report will be provided to your office if additional information is identified.

Tlie environmental specifications identified in the attachments were obtained from our FSAR. In a few cases where the FSAR did not identify a specifica-tion, the appropriate value was obtained from the purchase order for the specific item. The FSAR values are appropriate for this review since they define the expected post-accident conditions which will exist in the plant. The equipment qualifications were obtained from available documentation as noted on each sheet. All qualification methods are prototype tests; further definition of the specific qualification method is given in the attached pages.

APR 14 000

- I

Mr. J. G. Keppler April 10, 1980 Page 2 Containment submergence considerations is an item which has received considerable attention in the past. We have indicated the submergence considerations for each item; further clarification on this can be obtained in the letter of February 20, 1976, to Mr. R. A. Purple, Chief of Operating Reactors Branch #1, NRC, from E. W. James, Senior Vice President, Power Supply and Engineering, WPSC.

Terminal strips used in various systems do not have adequate qualification documentation . This item was first discovered in our review of IE Bulletin 79-01. At that time we encased each applicable terminal block in NEMA 12 enclosures, anu sealed the terminations in a qualified epoxy to' protect the wire terminatf ons from the harsh environment which may be produced from a LOCA or liELB event. Th.'s action eliminated the safety concerns involved, however, we are pursu.ng quaiification of the terminal strips in cooperation with Northern States Power Company to provide ultimate resolution to this issue.

Bulletin 79-01B requestei information which would verify that all equipment req sired to operate durind or following an accident is capable of functioning under the post-accident environmental conditions for the time periods required.

We would like to point out that this concern was discussed and resolved during the licensing of the Kewaunee Plant. Our FSAR, which was approved by the AEC, discusses at length the post accident conditions and required qualifications for applicable equipment. (See Section 7.5 of the Kewatmee FSAR.) The AEC, in their Safety Evaluation of the Kewaunee Plant, Section 7.5, issued July 24, 1972, concluded that our criteria and testing program for environmental qualification were adequate. The staff also reviewed and approved our Quality Assurance Program which is charged with the responsibility of assuring compliance to applicable standards and commitments made to guarantee the safety of the public through high quality of workmanship and materials.

Independent reviews and inspections by representatives of the staff during and after the construction of the Kewaunee Plant have verified that our l

equipment meets or exceeds applicable environmental qualifications commitments.

Our review to date of equipment qualifications in response to Bulletin 79-OlB l

l supports this conclusion; we have not to date identified any deficiencies which would lead us to believe otherwise.

Very truly yours, a

E. R. bathews, Vice Prepident Power Supply & Engineering snf At ta ch.

Subscribed and Sworn to Before Me ,

This JD4h_ Day of April 1980 l 3C$h E $ ED%C-C-( ~27.

' Notary Public, State of' Wisconsin 1 I

My Commission Expires

/0Dll/> / 9 / 9,$' J' \

l

./

I

MASTER LIST e SYSTEM: 18 Reactor Building Vent (RBV)

COMPONENTS

  • PLANT LOCATION IDENTIFICATION INSIDE PRI!!ARY OUTSIDE PRI!!ARY NUtmER CENERIC NAME CONTAIN1ENT CONTAllDENT 1-120 Motor CV 1-121 Motat CV 1-156 Motor CV 1-157 Motor CV 1-583 Motor CV 1-564 Motor CV 32145 MV 628/Reac.

32146 MV 628'/Reac.

im f

SYSTEM COMPONENT EVAI.UATION WORRSHEET ,Ff l k

0 UNIT: KD7AUNEE /,>'7 -

DCCRET: 50-335

'e e ../

EWIROMNT DOCUMENTATION REF*

QUALIF OUTSTANDING EQUIPMENT DESCRIPTION PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD ITEMS SYSTEM: 18 OPERATING mn s 1 PLANT ID NO.: 1-120, TIME ,

1-121, 1-156, 1-157 CCMPONENT: MOTOR TEMP.

268 F 300 F 1 4 Simult None Deg. F.

MANUFACTURE: Relianc'e PRESSURE 60.7 PSIA 80 PSIA 1 4 Simult None PS W MODEL NJMBER: Type N RELATIVE HUMIDITY 1007, 100% 1 4 Simult None

(%)

FUNCTION: Fan Driver CHE'3ICAL g

pH 8.0 pH 9.5 2 4 Separate None ,

ACCURACY: SPEC. 8

/A RADIATION 7 5 x 10 rads 1.9 x 10 rads 3 4 Separate None DEMON:

l SERVICE: Containment Fan Coil Unit AGING 40 years 4 Separate 1:one -

LOCATION: Containment FLOOD LEVEL ELEV 599.88 SUB-ERGM A30VE FLOOD LEVEL: Yes

  • DOCU'ENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5
2. FSAR Questions and Answers Supplement. Question 6.13.1
3. Purchase Order K-161, Specification SS M605 (WPS) 1-70
4. Qualification Test - Joy Axivance/ Reliance Electric Motor Company April 29, 1969. P.O. K-161, Section 6

SYSTEM COMPONENT EVALUATION L'ORKSHEET UNIT: KEk'AUNEE DOCKET: 50-305 DOCDENTATION REF*

ENVIRONMENT QUALI" OUTSTA'iDI':G EQUIPENT DESCRIPTION PARAMETER SPECIFICATION SPEC. QUALIF. }ETHOD ITEMS QUALIFICATION SYSTEM: 18 OPERATING PLA'iT ID NO.: 1-583, I ##

TIME 1-584 COMPONENT: MOTOR TEMP.

268 F 300 F 1 4 Simult None Deg. F

~

MANUFACTURE: Reliance PRESSURE (PSIA)

MODEL NUMBER: Type N RELATIVE HUMIDITY 100% 100% 1 4 Sinult None

(%)

FUNCTION: Fan Driver CHEMICAL PH 8.0 pH 9.5 2 4 Separate None SPRAY ACCURACY: SPEC. N/A 7 8 RADIATION 5 x 10 rads 1.9 x 10 rads 3 4 Separate None DEM0d:

. I Su.iICE: Conta inment AGING Dome Ventilation Fan 40 years 4 Separate None LOCATION: Containment FLOOD LEVEL ELEV 599.88 SUB-MERGENCE A30VE FLOOD LEVEL: Yes .

  • DOCU!ENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5
2. FSAR Questions and Answers Supplement, Question 6.13.1
3. Purchase Order K-161, Specification SS M 605 (k'PS) 1-70
4. Qualification Test - Joy Axivance/ Reliance Electric Motor Company April 29, 1969. P.O. K-161, Section 6.

i SYSTEM Col'FONENT EVALUATION WORKSEEET , ,

UNIT: Y2VAUNEE ,

DOCRET: 30-305

. DEENTATION REF* QUALIF OUTSTANDING l

EQUIPMENT DESCRIPTICN

. l FAMMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD 'ITE}3 SYSTEM: 18 OPERATING FLANT ID NO.: 32145 & TIME .

32146 C0120NENT: MV TEMP.

268 F 330 F 1 3 Simult None MANUFACTURE: PRESSURE 60.7 PSIA 104.7 PSIA 1 3 Sieult None Contromatics -

Limitorque (PSIA)

MODEL NUMBER: SMB-000 RELATIVE HUMIDITY 100% 100% 1 3 Simult None

(%)

FUNCTION: CHEMICAL Valve Operator Not Required pH 9.25 4 Simult None ACCURACY: SPEC. N/A RADIATION 7 8 DEMON: 5 x 10 rads 2 x 10 rads. 2 5 Separate None SERVICE: Post LOCA Hydrogen Isolation MV AGING 40 years 5 Separate Nene LOCATION: 628 Reactor FLOOD LEVEL ELEV 599.83 SUB-

?2RG M A30VE FLOOD LEVEL: Yes ,

{

  • DOCUb2NTATION F2FERENCES: NOTES:
1. FSAR Section 7.5
2. Purchase Order K-565 Specification
3. UCAP 7410-L, Final Report FC2232-01
4. WCAP 7410-L, Section 1: Post Accident Environmental Conditions
5. WCAP 7410-L, Section 5: Valve Motor Operators .

1

MASTEli LIST SYSTEM: 33 Safety Injection (SI) t COMI'ONENTS ,

PLANT LOCATION IDEf'TIFICATION INSIDE PRI!!ARY OUTSIDE PRI!!ARY NLIMBER GENERIC NAME CONTAIN::ENT CONTAINMENT 32092 MV 600/Reac.

32093 MV 608/Reac.

32097 MV 600/Reac.

32098 MV 600/Reac.

32100 MV 608/Reac.

32101 MV 608/Reac.

1 m

4 i

l l

,i  !' ,

l .I[

G N

IS DM

E F A'

T!

! e n

e n

e n

e n

e e e n

n n 2 S o o c o o o o 5 T N N N N N N N 1 U .

O , eg ri us

/..

,' Is iI i

e e t p j- - D t t t t t t t a IO l l l l l a a r5 LH u u u u u r r e t AT m m m m n a a pe UE i i i i i p e

p mr QI S S S S S S S e eu t s s

ee

  • h r t p F .

E F .

R I rd L 4 4 4 4 5 6 6  :

S on N A F a O U E I Q I T O .

A l I N 1 T

T N E

E E C.

1 1 U E 1 1 2 3 3 E C P S

K O S R D O f W

N N A s O O I d I I S 5 a s s T T P 2 r r n A A  % a o U C r F e L I a* 7, 0 0

9 0 y i

t A F e 7 4 1 H 1 i V I y 8 0 p 0 d E L A 1(

" 2 1 x 4 n T U o 2 1 C N Q .

E 3 1 N 1 n O s . t P T s d 68 n M N N c a 5 e O E O e A r n2 m C M I n*p I s o6 ns N T e S S r i7 o r M O A op*h F P 0, 0 a e t6 ro E R C c 1 s i t T I I 7,  % 8 y en va S V F d e 8 0 x uo nr Y N I e#T 6 0 0 H 0 Qi E e S E C k 2 6 1 p 5 4 p E c*r ,ta t O P o e 1 t c n S L p ni1 er ef0d o mi it ec2 co lp p2e3A cM R G N E

-  : N . E EY L O C pS2 e R VT A - N u ,Ct

- sl v 1 I . F ) I E T S U A II C T G 3E S A E1 M . S I TD) I g A N UG 0Foa R R I E g S S AI% M I I SR s2 PV F

A E T P

T e r

E P R (

LM(

EU E

H g D A

G A

E M

r2 t e r F O P 'RH C R  : wro:  :

_ S s e p1 5,~

3 E nd e i . f s i C ArRnnI N

O '

0 g r.5

o. . e N E d O

li i o o I

0 A e 't 9 Y R 5 a npat t T

- / . l c 9  : E o n c, e g

P B N: a 5 L F hi ce E

M .N d 'e V E E 7 sSFSS I e S CO l R n E R u o / E V R noe N 3 C q r EM c 0 L E U 0 S  : V r  :

o PE V0 E L N ioisLLLt u- - -

A 3 E 7M  :

o R t SD IM 6 O t so000 W - D O9 N0 Et Ri E

B a

r S L E

D C

I ceh1 1 1 T e u g4 4 4 E 0 3  :

Um M e n A SQn777 K 3 T N

3 D3N 2 T Ti U Np Y :iN o: V E

O L T i E  : I E CL N OO C E O L F N M M ,N A/ I A C Ia t RRt PPP T

P E T2 O Fn L Te R I l T D E G SS AA sAAA eCCC

I T N9 P Ua E Cv U VoA O V U' T G '. U S A0 M Nl D Nl C RsC O 0 C FFWWWW I C Q Y L2 O Ae 0: Ua C EIO L 3 O N O E S F3 C PV 1 FV A S L T A D . . . . . .

U D ,

  • 123456

SYSTEM CO}TONENT EVALUATION *a'ORKSHEET . .

UNIT: KEWAUNEE ECCF.ET: 50-305

- A OUTST E ING EQUI?}ZNT DESCRIPTION QUALIF PARDETER SFECIFICATION QUALIFICATION S?EC. QUALIF. FETHOD .' ITEMS STSTEM: 33 OPERATING 1 year PLANT ID NO.: TI}2 .(note 1) 4 Simult None 32093, 32098 CO.90NENT: MV TEMP. o o Dog. F.

MANUFACTURE: PRESSURE .

Velan/Limitorque 60.7 PSIA 104.7 ?SIA 1 4 Simult None  :

(73 3 )

5 MODEL NUMBER: SMB-00 RELATIVE HUMIDITY 100% 100% 1 4 S imult None

{

(%)

i FUNCTION
~ CHEMICAL Valve Operator 3p37 pH 8.0 pH 9.25 2 5 Simult Nonc j ACCURACY: SPEC. N/A 8 8 DEMON, RADIATION 1.5 x 10 rads 2 x 10 rads 3 6 Separate None I

SF.RVICE: SI reactor i' vessel isolation MV, AGING 40 years 40 years 3 6 Separate None .

LOCATION:

FLOOD LEVEL ELEV 599.68 SU3-ABOVE FLOOD LEVEL: Yes NM

  • DOCUMENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 1. ror the temperature 152 F
2. FSAR Questions and Answers Supplement, Question 6.13.1 and press.re 5 psig.
3. Westinghouse Shop Order 220, Spec M ication 676258
4. WCAP 7410-L, Final Report F-C2232-01
5. WCAP 7410-L, Section 1: Post Accident Environmental Conditions ,
6. WCAP 7410-L, Seption 5: Valve Motor Operations 4

SYSTEM CCYFONENT EVALUATION WORKSHEET . .

UNIT: KE*iAU'?EE DCCTIT: 30-305 E D CU'ENTATION E* QUALIF OUTSTANDING EQUIP >ENT DESCRIFTION l?ARAMETER SPECIFICATION QUALIFICATION SPEC. QUllIF. IETHOD 'IIIYS SYSTEM: 33 OPERATING Open during :1 year PTANT ID 50.: TI12 .

32100, 32101 CCMFONENT: MV TEMP. '

268 F 287 F 1 4 Simult None ,

Deg. F.  ;

MA' UFACTURE: PPISSU?E Velan/Limitorqu 60.7 PSIA 104.7 PSIA 1 4 S in. ult None l (PSIA) ,

MCDEL NUdSER: SMB-1 FILATIVE HUMIDITY 100% 100% 1 4 Simult None [

. (%) ,

FUNCTION:

. CHEMICAL pH 8.0 pH 9.25 2 5 Simult None  :

Valve Operator spgAy j  ;

. I i ACCURACY: SPEC.N/A 8 8 RAD ATION 1.3 x 10 rads 2 x 10 rads 3 6 Separate None DEMON:

SERVICE: Low Head SI to t A IN 40 years 40 years l SeparateNone eg g g gessel Iso. MV- 3 6 t

i .

FLOOD LEVEL ELEV 599.88 SUB-15RGENCE A30VE FLOCD LEVEL: 'Yes ,

i

  • DCCC:GNTATION FIFEPINCES: NOTES:
1. FSAR section 7.5 1. For the temperature 152 F and
2. FSAR Questions and Answers Supplement, Question 6.13.1 the pressure of 5 psig.
3. Westinghouse Shop Order 220, Specification 676258 4 WCAP 7410-L, Final. Report F-C2232-01
5. WCAP 7410-L, Section 1 : Post Accident Environmental Conditions .
6. WCAP 7410-L, Sgetion :5: Valve Motor Operators i

MASTER LIST SYSTEM: 34 Residual llent Removal (RllR)

COMPONENTS PLANT LOCATION IDENTIFICATION INSIDE PRI!!ARY OUTSIDE PRI!!ARY CENERIC NAME CONTAINMENT C0f;TA7 t'ME!;T NUtGER

~

16695 LA 595/Renc.

16696 LA 595/Reac.

h t

r_______-_______

i SYSTEM CCM?0NENT EVALUATION WCRRS'i??- . -

UNIT: KE'lAUNEE DOCRET: 50-305 4

ENVIRO M NT 'DOCUMINTATION PIF* OUTSTA': DING EQUI? MENT DESCRIPTION QUALI?

PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD ITE75 SYSTEM: 34 0FERATING J '

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 1 4 Simult None PLANT ID NO.: TIME -

16695, 16696  ;

COMPONENT: TEMP.

Level Indicator / Alarm , 7, 268 F 275 F 1 4 Simult None -

~

MANUFACTURE: PPISSURE

^ * ^ "

Magnetrol (PSIA) b MODEL NUMBER
RELATIVE W A-153 FEPIDM HUMIDITY 100% 100% 1 4 Simult None M '(%)

FUNCTION: Alarm - CHEMICAL D- pH 8.0 pH 9.5 2 4 Sequent None ,

g SPRAY w _=

Eff h

ACCU 3ACY: SPEC. N/A DEMON:

RADIATION 6

7.2 x 10 rads 7

'"

  • E "" "

see nete 1 I

. dim.'

$~5~ ~.- SERVICE: RHR Sump B C~ Level . AGING ,

LCCATION: 595/ Reactor j FLOOD LEVEL ELEV 599.83 SUB-A30VE FLOCD LEVEL: Yes Required Yes 3 4 Separate ,

None

  • DCCU:GNTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 1. FSARsecgion7.5statesthat
2. FSAR Question and Answers Supplement, Question 6.13.1 3.6 x 10 rads is the maximum
3. Purchase Order K272 Specifications hourly dose in the containment.

4 Environmental Testing Corporation, Test Report #9306 For two hours the dose is

5. Environmental Testing Corporation, Test Report #9306, supplement #1 < 7 s2 x 10 . rads.
6. Letter dated 7 4-72 from Magnetrol

MASTER LIST SYST!G1: 35 Chemical and Volume Control (CVC)

C0!!PONENTS PLANT LOCATION IDI,NTIFICATION INSIDE Pal!!ARY OllTSIDE PlIMARY Nt111BER GEl:ERIC NAME C01:TAIMMENT CONTAI!!ME!!T 32124 MV 613/Renc.

p6 _

9 4

m 4

I l

SYSTEM COMPONENT EVAL"ATION */CRKSEEET . .

UNIT: KEWAUNEE '

DOCTIT: 50-305 E VIF.ONMENT lDOCUMENTATIONREF* CUTSTA'CING EQUIPMENT DESCRIPTION QUALIF PAFE ETER SPECIFICATION QUALIF. METHOD ITEMS l QUALIFICATION lSFEC.

SYSTEM: 35 OPERATING 1 year 7 Analysis None

. PLANT ID NO.: 32124 TIME r-4 COMPONENT: MV TEMP. l 268 F 287 F 1 4 Simult None

, Deg. F.

,T -

p MANUFACTURE: PRESSURE 3 .

Aloyco/Limitorque 60.7 PSIA 104.7 PSIA 1 4 Simult None M XODEL NUMBER: SM3-00 RELATIVE i 100% 100% 1 4 Simult none G g HUMIDITY l W

FUNCTION:

CHEMICAL

%29 Valve Operator pH 8.0 pH 9.25 2 5 Simult None SPRAY

@ ACCURACY: SPEC. N/A pygg3; RADIATION 8 1.5 x 10 rads 8

2 x 10 rads 3 6 Separate None l

. t SERVICE: Seal watier E ' ACING l

1eakoff shut off MV  ; 40 years 40 years 3 6 Separate None  !

LOCATION:  ;

g I

FLOOD LEVEL ELEV 599.88 SUB- t MERGENCE '

A30VE FLOCD LEVEL: Ye8 ,

I t .

  • DOCUMENTATION REFEPINCES: NOTES:
1. FSAR section 7.5 . 1. For temperature 152 F and
2. FSAR Questions and Answers Supplement, Question 6.13.1 pressure 5 psi:;
3. Westinghouse Shop Order 220, Specification 676258
4. WCAP 7410-L, Final. Report F-C2232-01
5. WCAP 7410-L, Section 1: Post Accident Environmental Conditions
6. WCAF 7410-L, Seption 5: Valve Motor operators
7. Letter dated May, [973, from Limitorque to Pioneer Service Engineering Corporation

MASTER LIST SYSTE!!: 36 Reactor Coolant (RC)

COMPONENTS .

PLANT LOCATION IDENTIFICATION INSIDE PRIt!ARY OUTSIDE PRI!!ARY NUMBER GENCRIC NAME CONTAINMENT CONTAIIDIEf;T 21079 P XMTR 611/ React.

21080 P XMTR 611/ React.

21081 P XKER 611/ React.

21082 P XMTR 611/ React.

24030 L DITR 611/ React.

24031 L XMTR 611/ React.

24032 L XMTR 611/ React.

f

SYSTEM C0120NENT EVALUATION WORKSHEET . .

UNIT: KEWAUNEE DCCKET: 30-305 ENVIRONMENT l 'DOCU>ENTATION REF*

rQUIFMENT DESCRI" ION

~ QU'Dr' OUTSTANDING PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. IETHOD JITE}G SYSTEM: 36 OPERATING one half hour .24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 1 3 Simult None FLANT ID NO.: 21079, TIE -

21080, 21081, 21082 COMPONENT: Pressure ' TEST .

Transmitter -

268 F 300 F 1 3 Simult None

.Deg. F.

MANUFACTURE: Foxboro FRESSURE 60.7 PSIA 74.7 PSIA 1 3 Simult Ncne i

MODEL NUM3ER: RELATIVE E11GM-SAE-1/MCA HUMIDITY 100% 100% 1 3 Simult None

(%)

FUNCTION: Pressure CHEMICAL Measurement pH 8.0 pH 9.25-10.0 2 3 Separate None gpRAY ACCURACY: SPEC. 6 8 RADIATION 1.9 x 10 2 x 10 1 3 Separate None DEMON:

(Note 1)

I SERVICE: Przr P Transmitter AGING

! LOCATION: 611/Reac.

FLOOD LEVEL ELEV 599.38 SU3-A30VE FLOOD LEVEL: yes EG CE 9

  • DOCU'EN'IATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 1. FSAR Section 7.5 states that
2. FSAR Questions and Answers Supplement, Question 6.13.1 3.6 x 10 6is the maximum
3. WCAP 8541, Seismic.and Environmental Testing of Foxboro Transmitters, hourly dose in containment.

July, 1975. For one half heur. dose 1.9 x 106 . rads.

' s i .,

SYSTEM C0120NENT EVALUATION k'0FJsSHEET . .

UNIT: KEWAUNEE DCCT2T: 50-305

! ENVIRONMENT ' DOCUMENTATION REl'* OUALI'r OUISTANDING EQUIPMENT DESCRIPTION' PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. 15THOD . ITEMS SYSTEM: 36 OPERATING half hour 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 1 3 Simult None PLANT ID NO.: 24030, TIME -

24031, 24032 '

COMPONENT: TEMP.

Level Transmitter 268 F 288 F 1 3 Simult None Deg. F.

MANUFACTURE: Bartou- PRESSURE 60.7 PSIA 74.7 PSIA 1 3.

Simult None

! (PSIA) [

7 e

MODEL NUMBER: P386/351 RELATIVE HUMIDITY 100% 100% 1 3 Simult None ,

'(%) [

FUNCTION: CHEMICAL i Level Transmitter pH 8.0 pH 9.5 2 3 Separate None ACCURACY: SPEC.- '

6 RADIATION 1.9 x 10 rads 1.8 x 10 rads 1 3 Separate Mone DEMON: (Note 2) t SERVICE:

Pressurizer Level -ACING LOCATION: 611/ Reactor l -

I FLOOD LEVEL ELEV 599.SS SUB- -

ABOVE FLOOD LEVEL: Yes '

  • DOCUMENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 1. FSAR section 7.5 states that 3.6
2. FSAR Questions and Answers Supplement, Question 6.13.1 x 10 rad is the maximum hourly
3. WCAP 7410-L, Topical Report of Environmental Testing of dose in containment. For one D

Engineered Safety Fea,tures related equipment half hour 11ose is41.9 x 10 rads.

l .

I *

~

l

HASTER LIST

, SYSTEM:

COMPONENTS .

PLANT LOCATION IDENTIFICATION INSIDE PRI!!ARY OUTSIDE PRTIIARY NLIMBER GENERIC NAME CONTAIN:ZNT CONTAIIRfENT Okonite Cable X X B1 h' ' Cable X X

/ , Kerite Cabic X X Chevron BRB-2 Grease X X Nebula-E550-EP-1 Grease X D. G. O'Brien Electrical Penetrations X X GE 74010/74010A Epoxy Varnish X 6

9 e

. I l

1

suice.uveevacas c%utwa n w.a ni.i. .

UNIT: KEh*AUNEE DOC;GT: 50-305 ENVIR0 DENT ' DOCDENTATION REF* QUALIF OUTSTANDING TQUm'

~ ~ ~ ' ~ 'TNT DESCRI"~ ~ ION PARAlETER SPECIFICATION QUALIFICATION SPEC. QUALIF. >ETHOD  :'ITE} S SYSTIli: ,

OPERATING PLANT ID NO.: N/A TISE '

CC:20NENT: Cable TE!E .

268 F 346 F .1 3 Simult None

, Dcg. F.

P.ANUFACTURE: PRESSURE Ohonite (PST.A) 60,7 PSIA 127.7 PSIA 1 3 Simult None MODEL NUlGER: RELATIVE

, HUMIDITY 100% 100% 1 3 Simult None

(%)

i FUNCTION: CHEMICAL PH 8.0 pH 9.5 2 4 Simult None SPRAY ACCURACY' SPEC 7 8 4 RADIATION 5 x 10 rads 2 x 10 rads 1 3 Separate None EEMO.k:

SERVICE: -

AGING 40 years 40 years 1 3 Arrhenius None

{ LOCATION: Cont. Aux. Bldg, f FLCOD LEVEL ELEV 599,88 SUS-AECVE FLOCD LEVEL:

k

  • COC'uTENTATION

REFERENCES:

. NOTES:

1. FSAR Section 7,5 2, FSAR Questions and Answers Supplement, Question 6.13,1
  • 3, Pioneer Service and. Engineering Company, Vendor Certification and Testing 4 The Okonite Company, Prototype Test, November 12, 1970 r

w.... ..._w..... . . . . . . . . . . . , . . . . .

UNIT: KEWAUNEE DOCKET: 50-305 I

ENVIRONMENT ' DOCDENTATION REF* QUALI . OUTSTANDING TQUI?tiENT

"OSCRIPTION

~~ . PARA}ETER SPECIFICATION SPEC. METHOD ITEMS QUALIFICATION QUALIF.

SYSTEM: OPERATING

?LANTIDNd.: TI12 -

C0120NENT: Cable TEMP.

268 F 300 F 1 3 Simult None Dcg. F.

l'ANUFACTURE : BIU

l. PRESSURE 60.7 PSIA 65 PSIC 1 3 Simult Nonc

{ (PSIA) i i MODEL NUMBER: RELATIVE HUMIDITY 100% 100% 1 3 Simult None

'. (%)

FUNCTION: CHEMICAL p.H 8.0 pH 4.10 2 4 Sequent None ACCURACY: SPEC.- 1 7 8 i RADIATION 5 x 10 rads l'x 10 rads 1 4 Simult None DEMON: .

l

.i SERVICE: * - -

AGING LOCATION: Cont. Aux. Bldg. 40 years 40 years 1 3 Seporate None

_l 1

FLOOD LEVEL ELEV 599.88 SUB-

- 'IRGENCE ABOVE FLCCD LEVEL:

  • r
  • DOCU'GNTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 '
2. FSAR Questions and Answers Supplement, Question 6.13.1 ,
3. BIU Bostard Cables Report No. B901
4. BIW Report No. B904' July 15, 1970 1

) -

S

  • _4- _ _ _ _ _ _ _ _ _ _ . _ . _ . _ _ _

SYSTEM COMPONENT EUALUATiON WOMSMEET UNIT: KEWAUNEE DOCKET: 50-305 ENVIRONMENT ' DOCUMENTATION REF* OUTSTANDING EQUIPMENT DESCRIPTION QUALIF PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD ITEMS i SYSTEM: GPERATING PLANT ID NO.: N/A TIME COMPONENT: Cable TEMP.

268 F 3250 F 1 3 Simult. NONE Deg. F.

MANUFACTURE: Kerite PRESSURE 60.7 PSIA 96.7 PSIA 1 3 Simult. NONE MODEL NUMBER: RELATIVE HUMIDITY 100% 100% 1 4 Simult. NONE

(%)

FUNCTION: CHEMICAL I pH 8.0 PH 9.5 Simult NONE l 2 3 j SPRAY ACCURACY: SPEC.

RADIATION 5 x 107 1 x 108 rads 1 3 Simult. NONE

! DEMON:

SERVICE: -

AGING Separate 40 years 40 years 1 4 NONE l LOCATION:k{}otainment&

Aux. Hui 1ne FLOOD LEVEL ELEV 599.88 SUB-ABOVE FLCOD LEVEL:

  • DOCUMENTATION

REFERENCES:

, NOTES:

1 FSAR Section 7.5 ~- ~

2. FSAR Questions and Answers Supplem'ent', ' Quest' ion 6.13.1 ,
3. Final Report F-C2737 The Franklin Institute Research Laboratories Misc. Certification.
4. Section 6.. WCAP-7410-Vol. II ' Westinghouse

. d

s xs Aces cum vana A Leal.un A Ava wuson.a A UNIT: KEWAUNEE DOCIET: 50-305 ENVIRO M NT ' DOCUMENTATION REF* OUTSTANDING EQUIPMENT DESCRIPTION QUALIF PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. >ETHOD ITEks SYSTEM: R.B. Vcntilation OPERATING NONE PLANT ID NO.: TIFE

, COMPONENT: TEMP. o o Lubrication Grease' 268 F 350 F 1 2 Separate 303g Dag. F.

MANUFACTURE: PRESSURE Chevron BRB-2 60.7 PSIA See Note 1 1 NONE SRI-2 (PSIA)

MODEL NUMBER: RELATIVE HUMIDITY 100% See Note 1 1 NONE

(%)

i

FUNCTION: Lubrication CHEMICAL See Note 1 NONE i SPRAY ACCURACY: SPEC. 5 x 10 rad DEMON:

/ ^ See Note 1 2 x 10 rad 2 Separate NONE SERVICE: Fan Motors - NONE AGING

. LCCATION: Containment

. FLOOD LEVEL ELEV 599.88 SUB-MERGENCE A30VE FLOOD LEVEL: YES

  • DOCU1'ENTATION

REFERENCES:

, NOTES:

1. FSAR Section 7.5 1) Used in Containment Fan Coil
2. Chevron Oil Company Letter 3/14/73 .

Units and Dome ventilation fans and wrs qualified with the units.

9 9

a a a .. vw..c v.u.a i auu.wn.Ava n v um.a .

UNIT: I'IWAUNEE DOCKET: 50-305 QUAI,IF . OUTS M D EC EQUIPMENT DESCRIPTION PARAMETER SPECIFICATION SPEC. METHOD ITEMS QUALIFICATION QUALIF.

SYSTEM: MOV's OPERATING NONE PLANT ID NO.: TIME COMPONENT: Grease TEMP. NONE 8F Su h 1 1 Deg. F.

MANUFACTURE: Nebula PRESSURE 60.7 PSIA See Note 1 1 NONE (PSIA)

MODEL NU)BER: RELATIVE NONE E550-EP-1 HU'4IDITY 100% See Note 1 1

(%)

FUNCTION: Lubricate CHEMICAL See Note 1 See Note 1 NONE SPRAY ACCURACY: SPEC. 7 8 RADIATION 5 x 10 rad 1.5 x 10 rad 1 2 Separate NONE DEMON:

SERVICE: Limitorque '

Gears & Motor Bearings AGING See Note 1 See Note 1 NONE T OCATION: Containment FLOOD LEVEL ELEV 599.88 SUB-ABOVE FL.00D LEVEL:YES t ~.

ADOCU'4ENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5
2. Limitorque Corp. Letter 2/6/74 1) Used in Limitorque Motor

, Operators'which are quali-

. fied with grease.

j L _.

o o iwi uvc.r v.u.a i c., em, ww.i 6. v mar.t.~ .

UNIT: KE*.iAUNZE DOCKET: 50-305 ENVIR0 DENT ' DOCU'ENTATION

. REF* OUTSTANDING rqn ^^ ov"'

~ *'~" DESCRIo? ~^ ION QUALIF PA:WETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD  :' ITEMS SYSTEM: OPERATING

. 1 year 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> 1 4 Simult PLANT ID NO.: TIl2 COMPCNENT: Electrical TEMP.

! Penetration Deg. 7, 268 F 271 F 1 5 S faruit None i

MANUFACTURE
PRESSURE D. G. O'Brien pg 60.7 PSIA 66.7 PSIA 1 5 Simult None MODEL NUMBER: RELATIVE

. HUMIDITY 100% 100% 1 5 Simult None

(%)

FUNCTION: CHEMICAL pH 8.0 pH 9.5 2 6 Engr. None SPRAY Analysis ACCURACY-* SPEC 7 8 RADIATION 5 x 10 rads 3 x 10 rads - 1 7 Engr. None DIM 0h:

Analysis SERVICE: -

. AGING 40 years 40 years 3 See note 1 LOCATION:

FLOOD LEVEL ELEV 599.88 SUB-MERGENCE A30VE FLOOD LEVEL: Yes f

  • DOCU'ENTATION

REFERENCES:

NOTES:

1. FSAR Section 7.5 1. Aging requirement being
2. FSAR Questions and Answers Supplement, Question 6.13.1 investigated.

. 3. Purchase Order K268 Specification

4. D. G. O'Brien Tes't Report #C19QA053 of September 3, 1971
5. D. G. O'Brien Test Report-#3'9-1, 5 .

~6. Letter from Flucir Pioneer, Ics 'N WPS, 6/20/78

7. D. G. O'Brien, E'ngineering Repca , - #192 u __ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ________-________3_. ____

SYSTEM COMPONENT EVALUATION WORKSHEET UNIT: KEWAUNEE DOCKET: 50-305 ENVIRONMENT DOCUMENTATION REF* OUTSTANDING EQUIPMENT DESCRIPTION QUALIF PARAMETER SPECIFICATION QUALIFICATION SPEC. QUALIF. METHOD ITEMS SYSTEM: T,crainal Strip: OPERATING PLANT ID NO.: TIME COMPONENT: TEMP. Type Epoxy Coating 268 5000 1 3 NONE Deg. F.

t MANUFACTURE: GE PRESSURE

^

(PSIA)

! MODEL NUMBER: RELATIVE l 74010/74010A HUMIDITY 100% Water Resistant 1 4 Type NONE j (%)

j FUNCTION: Moisture CHEMICAL pH 8.0 pH 9.5 2 4 Proofing SPRAY DE"

(

ACCURACY: SPEC.

RADIATION' l DEMON: 1 x 109 1 5 Type NONE

SERVICE: -

LOCATION: Containment i

FLOOD LEVEL ELEV 599.88 SUB-l MERGENCE AB0VE FLOOD LEVEL:YES

  • DOCUMENTATION

REFERENCES:

. NOTES:

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ - ~ ~ ~ ~ -

1. FSAR Section 7.5 ~
2. FSAR Questions an'd Answers'Supplenent. Question 6.13.1

~

3. GE, H.C. Lauroesch Correspondence ~to J. King, Power Systems, August 7, 1978
4. GE, " Insulating"' Materials" Product' Data, 74010A Epoxy.

Resin plus 74010 Epoxy Catalyst" ' Mar ~cF24 l~1964-~dn'd~--

effect of radiation on materials. .