ML19309F847
| ML19309F847 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 03/07/1980 |
| From: | Belmore C, Maciolek N, Richards B Battelle Memorial Institute, COLUMBUS LABORATORIES |
| To: | |
| Shared Package | |
| ML19309F843 | List: |
| References | |
| 14969, NUDOCS 8005010433 | |
| Download: ML19309F847 (26) | |
Text
- -....,
8006010433 e
PROGRESS REPORT FOR Tile NINETEENTil QUARTER 1
6n i
I WOODBORER STUDY ASSOCIATEI, WITil Tile OYSTER CREEK GENERATING STATION to JERSEY CENTRAL POWER & LIGilT COMPANY March 7, 1980 by B.R. Richards, N.J. Maciolek, C.I. Belmore, and R.E. Ilillman Report No. 14969 November 9, 1979 to February 8, 1980
)
BATTELLE l
Columbus Laboratories William F. Clapp Laboratories Duxbury, Massachusetts 02332 Battelle is not engaged in roccarch for adocrtising, cales promotion, or publicity purposes, and this report may not be reproduced in full or in i
part for auch purpocca.
(
---.-...a==
l
'I I
TABLE OF CONTENTS Page I-INTRODUCTION.
1 PROCEDURES AND INTERIM DATA 1
Exposure Panels.
1 Water Q ality.
13 Teredinid Gonadal Development Studies.
13 LIST OF TABLES Table 1.
Geographical Locations of William F. Clapp I
Laboratories' Exposure Panel Arrays Submerged June, 1975, Barnegat Bay, New Jersey.
3 Table 2.
Summary Data for Incidence of Teredinidae in I
Panels Removed December 12-13, 1979 6
Table 3.
Summary Data for Incidence of Teredinidae in Pancis Removed January 7-9, 1980.
8 Table 4.
Summary Data for Incidence of Teredinidae in Panels Removed February 5-6, 1980 10 Table 5.
Sum.wy Data for Incidence of Limnoria tripmmbata In Panels Removed December, 1979, January, February, 1980 12 Table 6.
Water Quality at Exposure Panel Stations, December, 1979..
14 I
Table 7.
Water Quality at Exposure Panel Stations, January, 1980 15 Table 8.
Water Quality at Exposure Panel Stations, February, 1980.
16 Table 9.
Conditionn of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from December, 1979 through January, 1980..
17 LIST OF FIGURES Figure 1.
Outline of Barnegat Bay Showing Geographical Locations of Exposure Panels 2
I
I 1
- I WOODBORER STUDY ASSOCIATED WITH THE OYSTER CREEK GENERATING STATION by B.R. Richards, N.J. Maciolek, C.I. Belmore, and R.E. Hillman INTRODUCTION The William F. Clapp Laboratories of Battelle's Columbus Laboratories is conducting an investigation to determine whether the generating station is affecting the resident marine borer population in Oyster Creek to tha extent that that population is contributing significantly to marine borcr-caused damage in Barnegat Bay.
A description of the program and procedures used may be found in the Draf t Annual Report on Woodborer Stely Associated with the Oyster Creek Generating Station, Report 14968, dated February 9, 1980.
This report presents the summary data for the nineteenth quarterly period from November 9, 1979 through February 8, 1980.
I PROCEDURES AND INTERIM DATA Exposure Panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods of December 12-13, 1979, January 7-9, and Febrtiary 5-6, 1.980.
]
Long-term and short-term panels at all stations were retrieved and replaced.
Table 1 describes the geographical locations of the exposure sites. The summary data for the laboratory examination of the panels may be found in Tables 2 through 5.
..-~...:.a.
?!ANASQUAN INLLT ER1ELLE
/
I POINT PLEASANT I
INTRACOASTAL s
1?ATFRUAY CANAL MANTOLOKING I
KET LE CREEK I
l I
D p
o l
I
/
,,g SEASIDE ATLANTIC g
l OCEAN SLOOP CREEK IIOLLY PARK I
f og CEO STOUTS CREEK SEDGE yg
- II ISL D u
-10A 30 ps e,
.. OYSTER
- I 9..
f CREEK T,ARNECAT INLET OYSTER CREEK 6
7 a
a NUCLEAR GENERATING STATION
^
i 11ARETOWN CITY BARNEGAT BEACH E
C) PANEL ARRAY CONKLIN h
ISLAND t
I 0
1 2
} HILES 3
a BARNEGAT INLET, NEW JERSEY
%g l
~I Latitude 39" 45.8 N E
[
Longitude 74* 06.0 11 I
,I -
-0,---------,-0,.
EXPOSURE PANELS
)
TABLE 1.
GEOGRAPHICAL LOCATIONS OF WILLIAM F. CLAPP LABORATORIES' EXPOSURE i
PANEL ARRAYS SUBMERCED JUNE, 1975, BARNEGAT BAY, NEW JERSEY Structure to be used for Nearest Previous Approximate Latitude I
Site No.'
Site Suspension of Rack Data Stations and Longitude 1.
Barnegat Coast Guard Finger Pier WC 1 Lat. 39* 45.8'N
]
Station, Barnegat Inlet WFCL 1948-1967 Long. 74* 06.5'W 2.
Ashton Marina Bulkhead WC 13,14 Lat. 39' 40'N 1450 Bay Ave.
Long. 74* 13'W Manahawkin 3.
Iggie's Marina Bulkhead WC 16,17,18,19 Lat, 39* 45'N j
East Bay Ave.
Long. 74* 12.5'W Barnegat. (Conklin Island) 4.
Liberty Harbor Marina Bulkhead WC 21 Lat. 39' 47'N Washington Ave.
R. Turner Long. 74* ll'W w
Warctown Rutgers U.
4-A*.
Holiday Harbor Marina Bulkhead WC 21 Lat. 39* 48'N Lighthouse Drive R. Turner Long. 74* ll'N Waretown Rutgers U.
5.
_ Mouth of Cyster Creek, Dock WC 29,30 Lat. 39' 48.5'N Lot 4, Compass Road Rutgers U.
Long. 74* 10.3'W Offshore End 6.
Oyster Creek #1 Dock Lat. 39* 48.5'N Lagoon, Inshore End Long. 74* 10.35'W 37 Capstan Drive 7,
Private Dock End of Dock WC 27,28 Lat. 39 48.5'N
-Dock Aye.-
- R. - Turner '
Long. 749 ll. l ' W r -
Oyster Creek Rutgers U.
Sands Pt. Earbor Warctown s
i
W M
M M
M M
M M
M M
M M
M M
M M
M TABLE 1.
(continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 8.
Oyster Cretk-R.R.
Cross Member WC 26 Lat. 39* 48.7'N Bridge Bridge Rutgers U.
Lon.g. 74* 12'W Discharge Canal 9.
Forked River Cross Member WC 31 Lat 39' 49.2'N South Branch R.R. Bridge Rutgers U.
Long. 74* 12.2'W Intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 39* 50.1'N Bay Ave.
Long. 74*~_11.6'W Forked River 10A*.
Private Dock Under Dock Lat. 39' 49'N 1-16 Aquarius Ct.
Long. 74* 10'W Forked River 10B*.
Private Dock Under Dock Lat. 39* 49.4'N 1307 Beach Blvd.
Long. 74* 10.1'W.
Forked River
'11.
Forked River Bulkhead WC 35 Lat. 39" 49.7'N (near mouth)
Rutgers U.
Long. 74* 10'W 1413 River View Drive 12.
Stouts Creek Bulkhead WC 38,40,41 Lat 39* 50.5'N 1273 Capstan Drive R. Turner Long. 74* 08.8'W Wurtz Rutgers U.
13.
Rocknak's Yacht Basin End of Pier WC 46 Lat. 39' 52'N Seaview Ave.
Long. 74* 09'W Lanoka Harbor Cedar Creek m
M M
M M
M M
M M
M M
M M
M M
M M
M TABLE 1.
(continued) i Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude l
14.
Dicks Landing Pier WC 49 Lat. 39' 54'W Island Drive R. Turner Long. 74* 08.1'W t
Bayville (Holly Park)
Nelson 15.
Winter Yacht Basin Inc.
Pier WC 57 Lat. 40* 02.5'N l
Rt. 528 Long. 74* 03.5'W hantoloking Bridge W. Mantoloking 16.
Berkely Yacht Basin Pier WC 60,61 Lat. 39' 55.9'N J. Street Long. :74* 04.9'W
'Scaside 17.
Island Beach Pier WC 68 Lat. 39' 47.l'N State Park Long. 74* 05.9'W (Sedge Island)
All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Racks hung with nylon line from existing structures so the bottom panels are close to, but not touching the bottom. Racks at Forked River railroad bridge and Oyster Creek railroad bridge suspended with wire rope.
WC = Woodward-Clyde WFCL = William F. Clapp Laboratories
- Site 4-A installed April, 1977 Sites 10 A, 10 B installed April, 1978.
TABLE 2.
SUMMARY
DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED DECEMBER 12-13, 1979 No. of Percent Size Range Site Panel Specimens Filled in mm.
Species Identification Remarks 1
P*
400 99 5-75 100 T. navalis, 300 Teredinidae 75% of specimens dead.
C*
0 2
P 23 30 75-190 4 T. navaZis C
0 3
P 2
5 105-120 1 B. gouldi, 1 T. navalis C
0 4
P 6
13 50-150 6 B. gouldi' C
0 4A P
5 25 105-280 4 B. gouldi, 1 T. navalis C
0 5
P 400 99 (Tubes 10 T. bartschi, 39 Teredinidae 40% of panel missing. No broken) live specimens.
C 0
6 P
290 50
<1-85 170 T. bartschi,120 Teredinidae C
0 7
P 400 99 4-80 14 T. bartschi, 386 Teredinidae 10% of panel missing. No i
live specimens.
C 0
i 8
P 3
20 240-360 3 B. goulds C
0 9
P 3
15 90-280 3 T. navalis C
0 10 P
3 9
145-220 2 B. gouIdi, 1 T. navalis C
0 10A P
70 97 13-190 23 B. gouZdi, 47 T. bareschi C
0 L
I;.
~g M
M M
M M
M M
M
'l I ~ U ~ (__JU 1 f 1 T 1 I
L__)
TABLE 2.
(Continued)
No. of Percent Size Range site Panel Specimens Filled in mm.
Species Identification Remarks 10B P
9 55 140-330 7 B. gouldi, 2 T. navalis C
0 11 P
400 99 (Tubes 7 B. gouldi, 393 Teredinidae 30% of panel missing.
1 live broken) specimen.
Rest dead.
C 0
12 P
21 85 85-220 21 B. gouldi C
0 13 P
57 97 22-240 57 B. goulds C
0 14 P
64 99 50-145 64 B. gouldi C
0 15 P
2 7
140-160 1 B. gouldi, 1 T. navalis w
C 0
17 P
3 6
40-175 3 T. navalis C
0 Site 16 - no Teredinidae present.
I
- P = Long-term panel, subit:erged June 4-5, 1979 GC = Short-term panel, submerged November 5-6, 1979
m m
m m
m m
M M
m M
M M
M M
M M
M TABLE 3.
SU1 DIARY DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED JANUARY 7-9, 1980 No. of Percent Size Range Site Panel Specimens Filled in mm.
Species Identification Remarks 1
P*
400 99 8-80 220 T. navalis, 180 Teredinidae 30% of panel missing.
C*
0 2
P 15 35 45-190 13 T. navaZis, 2 Teredinidae C
0 3
P 5
15 70-140 4 B. gouldi, 1 T. navalic C
0 4
P 3
6 60-100 2 B. gouldi, 1 Teredinidae C
0 4A P
6 25 65-195 4 B. gouldi, 2 T. navalis C
0 5
P 393 99 7-190 3 B. gouZdi, 390 T. bartschi C
0 6
P 84 25
<1-130 39 T. bartschi, 45 Teredinidae 1 T. bartschi with umbonate larvae.
C 0
7 P
405 99 3-85 5 B. goulds, 200 T. bartschi, 15% of panel missing. No 200 Teredinidae live specimens.
C 0
9 P
1 6
230 1 T. navalis C
0 10A P
58 95 20-290 23 B. gouldi, 34 T. bartschi, 1 T. bartschi dead.
1 T. navaZis C
0 i
l 1
e e
m m
m M
M M
M e
m M
M M
~~
TABLE 3.
(Continued)
No. of Percent Size Range Site Panel Specimens Filled in mm.
Species Identification Remarks 10B P
5 15 25-230 3 B. gouldi,1 T. bartschi, 1 T. navalis C
0 11 P
284 99 12-130 4 B. gouldi,110 T. navalis, 40% of panel missing.
170 Teradinidae C
0 12 P
29 90 40-255 28 B. gouldi, 1 T. navalis C
0 13 P
12 45 70-170 12 B. gouZdi C
0 14 P
14 30 20-120 12 9. gouldi, 2 Teredinidae 3 dead.
C 0
e 15 P
11 35 60-90 3 B. gouldi, 7 T. navalis, 1 Teredinidae C
0 17 P
7 12 30-115 7 T. navalis C
0 Sites 8, 10, and 16 - no Teredinidae present.
CP = Long-term panel, submerged July 9-10, 1979
- C = Short-term panel, submerged December 12-13, 1979 i
['
t
m m
m m
m e
M M
M M
M M
M TABLE 4.
SUMMARY
DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED FEBRUARY 5-6, 1980 No. of Percent Size Range Site Panel Specimens Filled in mm.
Species Identification Remarks 1
F*
500 99
<1-34 300 T. navalis, 200 Teredinidae 40% dead. 1 T. navalis with ripening gonads.
C*
O 2
P 13 35 95-190 12 T. navalis, 1 Teredinidae C
0 4
P 5
9 42-105 2 B. gouldi, 3 T. navalis C
0 4A P
3 9
115-150 2 T. navalis, 1 Teredinidae C
0 5
F.
450 99 5-50 1 B. gouldi, 449 T. bartschi None live.
C 0
5 6
P 150 15
<1-105 21 T. bartschi, 1 T. navalis, None live.
4 T. bartschi 128 Teredinidae with dead larvae remaining in tubes.
C 0
7 P
500 99 6-45 55 T. bartschi, 445 Teredinidae None live.
C 0
8 P
2 5
45-225 1 B. gouldi, 1 T. navalis C
0 9
P 2
10 235 1 B. gouZdi, 1 T. narcIis C
0 10A P
97 35
<1-200 31 T. bartschi, 1 T. navalis, 60% of T. bartschi dead. 2 tubes 65 Teredinidae with dead larvae remaining.
C 0
10B P
4 13 25-195 3 B. gouldi, 1 T. navalie C
0 l
4 o
TABLE 4.
(Continued)
No. of Size Range Site Panel Specimens Filled in mm.
Species Identification Rcrarks 11 P
140 75 13-145 1 T. bartschi, 139 T. navalis T. bartschi dead. Larvac C
0 remaining in tube.
12 P
2 4
115 2 B. goulds C
0 13 P
2 4
130-140 2 B. gouldi C
0 14 P
11 30 60-205 8 B. gouldi, 3 T. navalis C
0 15 P
1 2
85 1 T. navalis C
0 17 P
4 4
25-85 4 T. navalis C
0
[:
Sites 3, 10, and 16 - no Teredinidae present.
- P = Long-term panel, submerged August 6-7, 1979 OC = Short-term panel, submerged January 7-9, 1980
I 12 TAELE 5.
SUMMARY
DATA FOR INCIDENCE OF Lisatoria tripwtetaba IN PANELS REMOVED DECEMBER,1979, JANUARY AND FEBRUARY,1980 I
December January February No. of No. of No. of No. of of No. of No.
Site Panel Tunnels Specimens Tunnels Specimens Tunnels Specimens 1
P*
19 0
0 0
CA 0
0 0
2 P
160 78 0
1 1
C 0
0 0
I3 P
0 0
1 1
C 0
0 0
I4 P
8 2
3 1
0 C
0 0
0 4A P
240 135 27 6
18 4
C 0
0 0
Sites 5-17, no Limnoria present.
- P = Long-term panel, submerged 6 months C = Short-term panel, submerged 1 month I
5 13 Water Quality Salinity, water temperature, dissolved oxygen, and pII were determined v'th.a llydrolab (Model Il B).
The results for December, 1979 January, and February, 1980 may be found in Tables 6 through 8.
l Teredinid Gonadal Development Studies i
Table 9 shows the gonad condition of the teredinid borers collected from December, 1979 through January, 1980.
Included are results from special long-term panels exposed for periods ranging from 12 to 17 months.
I
- I I
I
14 TABLE 6.
WATER QUALITY AT EXPOSURE P/NEL STATIONS, DECEMBER, 1979 I
Depth 0
Station Date Time in Feet Salinity (0/00)
Temp. ( C) pit (mg/1) 1 12/12/79 1010 6.0 23.6 7.3 9.8 8.5 2
12/12/79 1030 2.0 21.4 5.7 11.2 8.0 3
12/12/79 1107 3.0 15.2 6.3 11.0 8.1 4
12/12/79 1120 3.5 19.2 8.0 12.4 8.0 4A 12/12/79 1145 3.5 13.1 7.4 11.6 8.1 5
12/12/79 1207 4.0 18.5 11.7 10.0 7.9 6
12/12/79 1215 4.0 18.5 11.7 10.0 7.9 7
12/12//9 1235 3.0 17.9 13.4 10.9 7.8 8
12/12/79 1333 6.0 20.6 13.5 10.8 8.0 1
9 12/12/79 1347 6.0 21.3 9.5 11.4 8.1 10 12/12/79 1512 3.0 17.2 8.0 11.2 8.0 10A 12/12/79 1415 3.5 17.2 11.5 10.8 8.1 108 12/12/79 1425 3.5 16.5 10.0 11.2 8.0 11 12/12/79 1440 4.0 19.9 10.0 13.0 8.1 12 12/12/79 1535 3.5 18.5 7.5 12.0 8.1 12/12/79 1555 3.0 16.5 8.0 12.0 8.0
~
12/12/79 1612 3.0 15.2 7.0 12.2 8.2 25 12/13/79 1430 3.5 13.8 8.3 11.4 8.0 l
16 12/12/79 1750 4.5 13.1 7.9-11.5 8.1 17 12/12/79 1710 1.5 24.9 8.0 11.0 8.2 I
15 I
TABLE 7.
WATER QUALITY AT EXPOSURE PANEL STATIONS, JANUARY, 1980 IStation Depth 0
2 Date Time in Feet Salinity (0/00)
Temp. (*C) pH (mg/1) 1 1/8/80 0840 2.0 22.0 1.5 12.5 7.4 2
1/8/80 0920 2.0 18.2 0.5 13.0 7.5 3
1/8/80 101e 2.0 22.0 1.0 13.2 8.3 4
1/8/80 1030 3.0 21.3 2.5 13.0 7.8 4A 1/8/80 1115 3.0 19.9 2.5 12.4 7.3 5
1/8/80 1200 4.0 17.2 2.5 12.6 7.6 6
1/8/80 1215 2.0 17.6 2.0 13.1 7.2 7
1/8/80 1225 3.0 17.2 2.5 12.2 7.1 8
1/8/80 1340 3.0 15.2 2.5 13.4 7.2 9
1/8/80 1408 3.0 2.5 14.1 7.2 10 1/8/80 1545 3.0 17.2 3.0 12.4 7.3 10A 1/8/80 1525 2.0 21.3 2.5 14.0 7.3 108 1/8/80 1450 3.0 21.3 2.5 12.8 7.3 11 1/8/80 1505 3.0 17.2 2.5 14.2 7.2 12 1/8/80 1430 2.0 19.2 2.5 15.0 7.2 13 1/8/80 1605 3.0 11.8 3.0 12.6 7.0 14 1/8/80 1630 3.0 19.2 3.5 13.0 7.2 15 1/9/80 0750 2.0 19.2 0.5 7.4 16 1/9/80 0710 3.0 15.2 1.0 13.5 7.6 17 1/7/80 1600 2.0 20.6 1.0 14.4 8.1 I
- - Not taken
1 16
[
TABLE 8.
WATER QUALITY AT EXPOSURE PANEL STATIONS, FEBRUARY, 1980 Depth 0
2 Station Date Time in Feet Salinity (0/00)
Temp. (*C) pH
{
(mg/1) 1 2/6/80 0925 6.0 25.6
-0.2 13.1 8.2
[
2 2/6/80 0950 2.0 15.8 1.5 12.0 7.4 3
2/6/80 1030 3.0 13.8
-1.0 14.0 7.7 4
2/6/80 1115 3.5 21.3
-0.5 14.6 7.8 4A 2/6/80 1135 3.5 22.0
-0.5 15.6 8.1.
5 2/6/80 1205 4.0 8.7 0.0 6.7 6
2/6/80 1210 4.0 15.8
-1.0 6.8 7
2/6/80 1230 3.0 19.9 0.0 14.2 8.0 8
2/6/80 1245 6.0 19.2 0.0 8.2 I
9 2/6/80 1300 6.0 19.9 0.1 8.1 10 2/6/80 1500 3.0 4.1 1.0 14.0 7.4 10A 2/6/80 1400 3.5 13.8
-0.5 12.2 7.5 10B 2/6/80 1415 3.5 9.2
-1.0 8.0 11 2/6/80 1420 4.0 15.8
-1.5 8.1 12 2/6/60 1440 3.5 11.8
-0.5 12.4 7.3 13 2/6/80 1510 3.0 18.5 1.0 15.4 7.9 14 2/6/80 1515 3.0 15.8 1.0 15.4 8.0 15 2/6/80 1600 3.5 20.6 0.0 15.0 8.2 16 2/5/80 1710 4.5 13.8
-0.2 13.0 7.9 17 2/5/80 1415 1.5 19.9
-0.1 12.8 7.6
- - Ilydrolab malfunctioning
M M
M M
M M
M M
M M
M M
M M
M M
M TABLE 9.
CONDITION OF GONADS OF TEREDINID BORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM DECEMBER, 1979 THROUGH JANUARY, 1980 EA = Early Active; LA = Late Active; R = Ripe; PS = Partially Spawned S = Spent; M = Male; F = Female; H = Hermaphrodite Month No. Months Gonad Spreimen No.
Station Removed Exposed Species Sex Condition Comments 648a 14 Dec 79 6
Bankia gouldi M
S Many cysts; ciliates on gills, b
Bankia gouldi M
S Many ciliates on gills.
c Bankia gouldi M
S Cysts; many ciliates on gills.
d Bankia gouldi No discernable gonad; necrosis, mataplasia of digestive tubule epithelium; ciliates.
Bankia gouldi M
S Cysts; cosinophilic leukocytes, e
f Bankia gouldi M
S Cyst in gonad.
g Bankia gouldi F
LA h
Banhia gouldi M
S U
649a 10B Dec 79 6
Bankia gouldi M
S b
Bankia gouldi M
S Necrosis; leukocytosis, Bankia gouldi No discernable gonad, c
d Bankia gouldi M
S 650 10B Dec 79 6
Teredo navalis F
S Minchinia; abscesses; metaplasia
.of digestive tubules.
651 10 Dec 79 6
Teredo navalis F
R Unspawned; eggs undergoing cytolysis.
652 10 Dec 79 6
Bankia gouldi M
S Leukocytosis; necrosis, metaplasia of digestive tubules.
653a 17 Dec 79 6
Teredo navalis H
S b
Teredo navalis M
LA Necrotic.
e Teredo navalis H
LA Necrotic; metaplasia of digestive tubules.
M M
M M
M M
M M
M M
M M
M M
TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 654a 13 Dec 79 6
Bankia gouldi No discernable gonad; necrotic.
b Bankia gouldi M
S Necrotic; granulocytomas.
Bankia gouldi M
S c
d Bankia gouldi M
LA Cysts; sperm undergoing cytolysis; unidentified cells.
655a 4A Dec 79 6
Bankia gouldi No discernable gonad.
b Bankia gouldi M
S Necrotic digestive tubules.
c Bankia gouldi No discernable gonad.
d Bankia gouldi M
S 656 4A Dec 79 6
Teredo navalis H
LA 657a 12 Dec 79 6
Bankia gouldi M
S Necrotic.
b Bankia gouldi M
S y
c Bankia gouldi No discernable gonad.
d Bankia gouldi No discernable gonad.
Bankia gouldi M
S e
658a 6
Dec 79 6
Teredo navalis No discernable gonad; larvae in brood pouch.
b Teredo navalis No discernable gonad; necrotic.
c Teredo navalis No discernable gonad; larvae in brood pouch.
659a 2
Dec 79 12 Teredo navalis F
S Special panel; Ninchinia; necrotic; metaplasia of digestive tubules, b
Terado navalis M
S Minchinia; necrotic.
c Teredo navalis M
LA Minchinia; leukocytosis; cytolysis of gametes.
d Teredo navalis F
A Ninchinia; necrotic; metaplasia of digestive tubules.
i i
M M
M M
M M
M M
M M
M ~ M M
M M
M TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removeu Exposed Species Sex Condition Comments 659e 2
Dec 79 12 Teredo navalis M
S Minchinia.
E Teredo navalis H
S Minchinia; necrotic.
660a 4
Dec 79 6
Bankia gouldi M
S Metaplasia of digestive tubules.
b Bankia gouldi M
S c
Bankia gouldi M
S d
Bankia gouldi M
S Bankia gouldi M
S e-E Bankia gouldi M
S 661a 2
Dec 79 6
Teredo navalis M
PS Metaplasia of digestive tubules.
b Teredo navalis H
S Leukocytosis; metaplasia of digestive tubules, c
Teredo navalis M
S d
Teredo navalis H
S
- Necrotic, g
662a 8
Dec 79 6
Bankia gouldi No discernable gonad.
b Bankia gouldi M
S Necrotic.
Bankia gouldi No discernable gonad.
c 663 3
Dec 79 6
Bankia goulds M
S 664 3
Dec 79 6
Teredo navalis H
S Bankia gouldi M
S 665 11 Dec 79 6
666 12 Dec 79 16 Teredo navalis M
S Special panel; some leukocytosis.
667a 12 Dec 79 16 Bankia gouldi M
S Special panel; granulocytomas.
b Bankia gouldi M
LA
^
c Bankia gauldi M
S d
Bankia gouldi M
S Necrotic.
Bankia gouldi M
S Necrotic.
e f
Bankia gouldi M
S Necrottc.
g Bankia gouldi No discernable gonad; necrotic.
i
)
lll q
yo a
id a
a o
c c
i i
m e
i i
s n
s u
t t
a i
a s
o o
l h
l s
r r
p c
p i
c c
a n
t e
e t
i a
m.M n
n e
i e
n v
s; i
i dd d
- ed h
t aa a
al a ca c
nn n
i un ni e
oo o
db o id n
gg g
oug Mo n
mt m
o cc ee e
s e
- s
. c ii ll l,
ael l a l
tt l
bb b s l vb el ef oo e
aa ai pi a.
np no rr n
nn ns t na a
a cc a
rr.ro asri a
pa pss.ee.
p s
eecet c
i eed i
i ii cnnc t
cct cy i
ngco n
l n l ssi i
l n
ssr sc t
iism i
ai ayot ;;t a
e ii oio o
hdi s h
ih il rosso i
m dd tdk r
c d a c
cc cocrtt r c
m c
u c
nf l
n en et ecssc e
o ooeoe e
ioop i
pi puneyye p
C NNNNL N
M N
no di at S
ni P
L od G n o
C x
e M
MMM MnMHH huh HM MM MMMMM M
S sssss s
sss ss iiiiiii iiiii i
iii ii is iiiii s
ddddddd lllll l
lll ll dd ddddd d
lllllll aaaaa a
aaa aa ll lllll l
uuuuuuu vvvvv v
vvv vv uu uuuuu u
ooooooo aaaaa a
aaa aa oo ooooo o
ggggggg nnnnn n
nnn nn gg ggggg g
se aaaaaaa ooooo o
ooo oo aa aaaaa a
i iiiiiii ddddd d
ddd dd ii iiiii i
c kkhkkkh eeeee e
eee ee kk hkkkk k
e nnnnnnn rrrrr r
rrr rr nn nnnnn n
p aaaaaaa eeeee e
eee ee aa aaaaa a
S BBBBBBB TTTTT T
TTT TT BB BBBBB B
s hd t e ns oo 6
6 6
6 6
6 Mp 1
1 1
1 x
.E o
d N
eun i
t d
n he 9
9 9
9 9
9 o
t v 7
7 7
7 7
7 C
no om c
c c
c c
c Me e
e e
e e
e R
D D
D D
D D
9 E
LB n
A o
T i
t 2
1 9
1 1
7 a
1 1
1 t
S
.o N
ne hi 3k1 nn abcd e f
abc ab ab cdeE g m
7 8
9 0
1 2
i 6
6 6
7 7
7 c
6 6
6 6
6 6
ep S
TABLE 9.
Continued Month No. Months Conad Specimen No.
Station Removed Exposed Species Sex Condition Comments 673a 17 Dec 79 16 Teredo navalis M
EA Special panel.
b Terado navalis M
LA c
Teredo navalis H
S d
Terado navalis H
S Minchinia plasmodia.
e Teredo navalis H
S Minchinia p1'asmodia.
674 15 Dec 79 6
Bankia gouldi M
S Granulocytomas; leuicocytosis.
675a 10A Dec 79 6
Bankia gouldi M
S b
Bankia gouldi M
S Bankia gouldi M
S c
d Bankia gouldi M
S 676 15 Dec 79 6
Teredo navalis H
LA 677a 10A Dec 79 6
Teredo bartschi H
S b
Teredo hartschi No discernable gonad; larvae in brood pouch.
c Teredo bartschi No discernable gonad; larvae in brood pouch.
Terado bartschi H
S e
Teredo bartschi No discernable gonad.
678 10B Jan 80 6
Teredo bartschi H
R Gametes undergoing cytolysis; early larvae in brood pouch.
679a 4
Jan 80 6
Bankia gouldi M
EA b
Bankia gouldi F
EA 680a 10B Jan 80 6
Bankia gouldi M
S b
Bankia gouldi M
EA e
Bankia gouldi M
EA Necrotic intestinal epithelium, I
digestive tubules.
\\
o
m M
~ m M
M M
M M
M M
M TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 681a 13 Jan 80 6
Ban 3 cculdi F
EA Amorphous material in heart cells.
b Bankia gouldi M
EA Bankia gouldi M
EA Cyst; unidntified material in c
gonad; es. ensive leukocytosis.
d Bankia gouldi No discern.2ble gonad.
Bankia gouldi M
S e
f Bankia gouldi F
EA g
Bankia gouldi F
EA Necrotic digestive tubules, connective tissue, h
Bankia gouldi No discernable gonad.
682 10B Jan 80 6
Teredo navalis F
LA Gametes undergoing cytolysis.
[
683a 3
Jan 80 6
Bankia gouldi M
EA b
Bankia gouldi M
EA u~
Bankia gouldi M
EA c
d Banktc couldi M
EA 68A 3
Jan 80 6
Teredo navalis H
LA 1
685a 2
Jan 80 6
Teredo navalis F
LA Michinia; metaplasia, necrosis of digestive tubules, gametes undergoing cytolysis, b
Teredo navalis H
EA Metaplasia, necrosis of digestive tubules; granulocytoma.
c Teredo navalis F
LA Minchinia plasmodia (early);
gametes undergoing cytolysis, d
Teredo navalis M
LA Minchinia plasmodia.
e Terado navalis M
LA Minchinia plasmodia; cetaplasia, necrosis of digestive tubules.
f Teredo navalis M
LA Minchinia plasmodia.
.l g
Teredo navalis H
LA Minchinia spores and plasmodia.
686 9
Jan 80 6
Teredo navalis F
R Minchinia plasmo'dia.
>i
M M
M M
M M
XM WW M
MMX TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Co==ents 687a 15 Jan 80 6
Bankia gouldi M
EA b
Bankia gouldi F
EA Bankia gouldi M
S c
688a 15 Jan 80 6
Terado navalis 11 LA b
Teredo navalis 11 LA c
Terado navalis F
LA Gametes undergoing cytolysis, d
Terado navalis F
R Gametes undergoing cytolysis, e
Teredo navalis F
LA Gametes undergoing cytolysis; metaplasia of digestive tubules.
E Teredo navalis M
LA g
Teredo navalis H
LA Metaplasia of digestive tubules, necrosis.
689a 14 Jan 80 6
Bankia goulds No discernable gonad.
U b
Bankia gouldi M
EA c
Bankia gouldi M
EA d
Bankia gouldi No discernable gonad.
Bankia gouldi M
EA e
E Bankia gouldi M
EA g
Bankia gouldi M
EA h
Bankia gouldi M
EA i
Bankia gouldi M
EA J
Bankia gouldi M
EA h
Bankia gouldi M
EA 690a 4A Jan 80 6
Bankia gouldi M
EA Cysts in mantle; leukocytosis.
b Bankia gouldi M
EA Leukocytosis, c
Bankia gouldi M
EA d
Banhia gouldi M
EA 691a 4A Jan 80 6
Teredo navalis F
LA Gametes undergoing cytolysis; granulocytoma, b
Teredo navalis H
LA 4
t h
_. ~
TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 692a 6
Jan 80 6
Teredo bartschi H
PS b
Teredo bartschi No discernable gonad.
c Torado bartschi M
PS d
Toredo bartschi No discernable gonad.
e Terada bartschi H
PS Ciliates on' gills.
693a 17 Jan 80 6
Tarado navalis H
LA Minchinia plasmodia, b
Tcredo navalis 11 LA Minchinia plasmodia.
c Teredo navalis M
LA 694a 5
Jan 80 6
Teredo bartschi H
PS Gametes undergoing cytolysis; necrotic debris.
b Terado bartschi H
PS Gametes undergoing cytolysis.
c Torado bartschi No discernable gonad.
d Teredo hartschi No discernable gonad; all tissues necrotic.
n 695a 5
Jan 80 6
Bankia gouldi M
EA Cysts; metaplasia, necrosis of digestive tubules.
b Bankia gouldi M
EA c
Bankia gouldi M
EA 696a 10A Jan 80 6
Bankia goulds M
EA b
Bankia gouldi No discernable gonad; buildup of fibrous connective tissue.
c Bankia gouldi No discernable gonad.
d Bankia gouldi No discernable gonad; many ciliates in gut.
697a 10A Jan 80 6
Teredo bartschi H
PS Gametes, larvae in brood pouch undergoing cytolysis; many t
ciliates in section.
i b
Teredo bartschi H
PS Gametes undergoing cytolysis, c
Terado bartschi H
C i
d
TABLE 9.
Continued Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 698a 12 Jan 80 6
Bankia gouldi M
EA b
Bankia goulds No discernable gonad; fibrous connective tissue buildup, Bankia gouldi No discernable gonad.
c d
Bankia gouldi No discernable gonad.
Bankia gouldi No discernable gonad; fibrous e
connective tissue buildup.
E Bankia gouldi F
EA g
Bankia gouldi F
EA h
Bankia gouldi M
EA i
Bankia gouldi No discernable gonad.
J Bankia gouldi M
EA k
Bankia gouldi No discernable gonad.
1
.Banhia gouldi M
EA U
699a 7
Jan 80 6
Bankia gouldi No discernable gonad, b
Bankia gouldi Cysts; center of cysts contain masses of dark granular material; ciliates in gut, mantle cavity.
700a 1
Jan 80 6
Teredo navalis M
LA Minchinia plasmodia; ciliates on tissue.
b Teredo navalis M
LA Minchinia plasmodia, c
Teredo navalis M
LA Minchinia plasmodia; gonads necrotic.
d Teredo navalis M
LA Teredo navalis M
LA Minchinia plasmodia.
f Teredo navalis LA Minchinia plasmodia.
g Teredo navalis H
EA 701 11 Jan 80 6
Bankia gouldi M
EA Granulocytomas; many ciliates on gills.
702a 11 Jan 80 6
Teredo navalis H
LA b
Teredo navalis M
EA c
Teredo navalis M
EA d
Teredo navalis M
EA l!
i
)
' Ul R
R R
R R
R R
R R
R 1
i R
R R
' n R
n n
TABLE 9.
Continued l
Month No. Months Gonad Sp7eimen No.
Station Removed Exposed Species Sex Condition Comments 703a 12 Jan 80 17 Bankia gouldi M
EA Special panel, b
Bankia gouldi No discernable gonad.
Bankia gouldi No discernable gonad; mass of c
cells surrounded by fibrous material in tissue adjacent to caecum.
d Bankia gouldi M
EA e
Bankia gouldi No discernAle gonad.
f Bankia gouldi No discernable gonad.
704a 2
Jan 80 12 Teredo navalis M
EA Special panel; Minchinia, b
Teredo navalis EA Minchinia, c
Teredo navalis LA Minchinia.
d Teredo navalis PS Ninchinia plasmodia, y
e Teredo navalis H
LA Minchinia plasmodia.
~
f Teredo navalis M
EA Minchinia plasmodia.
g Teredo navalis M
EA Minchinia.
h Teredo navalis M
EA Minchinia plasmodia.
i Teredo navalis EA Minchinia plasmodia.
705a 17 Jan 80 12 Teredo navalis H
LA Special panel; Minchinia plasmodia, b
Teredo navalis H
LA Minchinia, c
Teredo navalis M
EA Minchinia.
706a 11 Jan 80 17 Bankia gouldi M
EA Special panel; multiple cysts.
b Bankia gouldi M
EA c
Bankia gouldi M
S d
Bankia gouldi F
S Multiple cysts; tissues necrotic, Bankia gouldi M
EA Metaplasia of digestive tubules; e
many ciliates in mantle cavity, s
a
__ _ _ _ -. _ _ _ _ _