o 800.4290493 b

DUKE POWER COMPANY Powen Dettorno 42n SocTn Cucacu Srazzr, Cruntorts, N. C. asa4a wiwau o.

anca.sa.

April 24, 1980 VeCF PRESeCENT TE6fp=C48 A#to704 S'ta= Peoewettow 273-4003 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr. R. L. Baer, Chief Light Water Reactor Project Branch No. 2

Subject:

McGuire Nuclear Station Do'cket Nos. 50-369 and 50-370 Evaluation of McGuire Containment

Dear Mr. Denton:

As requested in Mr. R. L. Baer's letter of March 10, 1980 Duke Power Company has reviewed the proposed Ames Laboratory statistical design parameters for the McGuire containment.

This review is attached as is the additional infor-mation requested by Mr. Baer regarding the equipment hatch and personnel air lock penetrations of the McGuire containment.

V y truly yours, g

Y o_

e Bgol j

William O. Parker, Jr.

///

WH:scs

$ 3rvD ov6t$n e d * **'jf Attachments to Iera feA b/m,'ny,Y4id Rilung 4o C3*bs) $l65.

McGuire Nuclear Station, Units 1 and 2 Containment Vessel Design Parametets USNRC Request for Additional Information A.

Duke Power Company has reviewed the Ames Laboratory table entitled

" Statistical Parameters for Design Variables, McGuire Nuclear Plant,"

enclosed in the aforementioned letter reference. The tabulated geometri-cal data appears accurate and reasonable. The tabulated data on material properties are at variance with properties of actual plate materials sup-plied for the McGuire Containments.

Enclosed is a statistical summary, developed by the Duke Engineering Staff, of material properties of Con-tainment plate and weld filler metal from certified mill test reports.

B.

Drawings of the equipment hatch and personnel air locks are enclosed as additional information. The following prints are included:

Manufacturer's McGuire Drawing No.

Drawing No.

Description 59-005-570-801 MCM 1132.00-29 Equipment Hatch MK-C412 30700 MCM 1132.00-01 General Arrangement - Air Lock 30700 30701 MCM 1132.00-02 Collar Details - Air Lock 30700 30702 MCM 1132.00-03 Shell Details - Air Lock 30700 30703 MCM 1132.00-04 Shell Details - Air Lock 30700 30733 MCM 1132.00-08 General Arrangement - Air Lock 30735 30736 MCM 1132.00-09 Collar Details - Air Lock 30735 30737 MCM 1132.00-10 Shell Details - Air Lock 30735 30738 MCM 1132.00-11 Shell Details - Air Lock 30735 1

I l