Order Confirming Util Commitment to Perform Review Requested by IE Bulletin 79-27 by 800626.Info Required Contained in Attachment a
ML19309F458
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 04/04/1980
From: Stello V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
GEORGIA POWER CO.
Shared Package
ML19309F437 List:
References
IEB-79-27, NUDOCS 8004290477
Download: ML19309F458 (5)


Text

.

f 8004 90 477 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of

)

Georgia Power Co.

)

Docket No. 50-366 l

(E. I. Hatch Unit No. 2)

)

f CONFIRMATORY ORDER i

I i

Georgia Power Company (the " licensee") is the holder of Facility Operating License No. NPF 5 (the " license") with an expiration date of December 27, 2012, which authorizes operation of the E. I. Hatch Unit No. 2 (the " facility").

II 1

On November 10, 1979, an event occurred at the Oconee Power Station, Unit 3, 4

that resulted in loss of power to a nonclass 1-E 120 Vac single phase power 1

panel that supplied power to the Integrated Control System and the Nonnuclear Instrumentation System.

This loss of power resulted in control system malfunc-tions and significant loss of information to the control room operator.

f This event was described in Information Notice 79-29, dated November 16, 1979, which was sent to this licensee.

This licensee was requested by IE Bulletin 79-27, dated November 30, 1979, " Loss of Nonclass 1-E Instrumentation and Control Power Bus During Operation" +' review, among other things, buses supplying power to certain instrument and control systems, emergency procedures related to loss of power to such buses and failure to certain_ power supplies.

In accordance wi,th Bulletin 79-27 the licensee was requested to submit to the Commission the results of its review by February 28, 1980.

This licensee _has not met this date.

l l

~l I

, On February 26, 1980, an event occurred at Crystal River Unit No. 3 that also involved a loss of instrument and control power.

This event was described in Information Notice 80-10, " Partial Loss of Nonnuclear Instrument System Power Supply During Operation," dated March 7,1980.

Because of the implications of the Crystal River Unit No. 3 event on February 26, 1980 and because of the potential adverse effects on public health and safety that could result from future events of this type, the information requested in IE Bulletin 79-27 must be submitted in order that NRC can determine whether this license should be modified to protect the health and safety of the public.

The Licensee has committed by letter dated March 26, 1980, supplemented by a telephone conversation between Commission representatives and Mr. T. V. Greene of the Licensee organization on March 25, 1980, that it would provide the information required by Bulletin 79-27 as revised in Attachment A to this Order, by June 26, 1980.

III In view of the importance of this matter, I have determined that these commitments should be formalized by order and that the public health, safety and interest require that this action be made immediately effective.

Accord-ingly, pursuant to the Atomic Energy Act of 1954, as amended, and the Commission's regulations in 10 CFR Parts 2 and 50, IT IS HEREBY ORDERED, EFFECTIVE IMMEDIATELY, THAT:

l (1) The licensee shall submit to the Director of Reactor Operations Inspection, Washington, D.C. 20555 and to the Director of the

appropriate NRC Regional Office, written statements under oath containing the information required in Attachment A to this Order; and (2) The licensee shall submit the statements on or before June 26, 1980.

IV Any person who has an interest affected by this Order may request a hearing within twenty-five (25) days of the date of the Order.

Any request for a hearing will not stay the effectiveness of this Order.

Any request for a hearing shall be submitted to the Director, Office of Inspection and Enforce-ment, U. S. Nucitar Regulatory Commission, Washington, D.C.

20555, with a copy to the Executive Legal Director at the above address.

If a hearing is requested by a person who has an interest affected by this Order, the Commiss' ion will issue an Order designating the time and place of any such hearing.

V In the event a person who has an interest affected by this Order requests a hearing as provided above and a hearing is held, the issues to be considered at such a hearing shall be:

(1) Whether the facts set forth in Part II of this Order provide an adequate basis for the actions ordered; (2) Wnether the Licensee should perform the actions required in Part III of this Order in accordance with the schedule stated therein.

t

.J

. Operation of the facility on terms consistent with this Order is not stayed by the pendency of any proceedings on the Order.

FOR THE NUCLEAR REGULATORY COMMISSION

~,. '

',. '/

'h Victor SteTTo, Jr Director Office of Inspection and Enforcement Dated at Bethesda, Maryland on this MS day of April, 1980 l

\\

Attachment A 1.

Review emergency procedures that will be used by control room operators, including procedures required to achieve a cold shutdown condition, upon loss of power to each class 1-E and nonclass 1-E bus supplying power to safety and non-safety related instrument and control systems.

At a minimum, the review shall assure that emergency procedures include:

a) the diagnostics / alarms / indicators / symptoms resulting from the review and evaluation conducted per item 1 of IE Bulletin 79-27.

b) the use of alternate indication and/or control circuits which may be powered from other nonclass 1-E or class 1-E instrumentation and control buses.

c) methods for restoring power to the bus.

Provide a description of the changes to the emergency procedures and administrative controls that have been prepared to.cnform to items la, Ib and Ic above and provide a description of ari schedule for implementa-tion of any design changes resulting from the changes to emergency proce-dures and adniinistrative controls.

.