ML19309F097

From kanterella
Jump to navigation Jump to search
Forwards Final Deficiency Rept Re Improperly Installed Reactor Coolant Drain
Date released: 11/19/2019 Download: ML19309F097


Final Deficiency Rept Re Improperly Installed Reactor Coolant Drain Line.Reanalysis by Util & Westinghouse Has Changed Nozzle & Support Loads.Two Snubbers Replaced
ML19309F103
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 03/03/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19309F103 (1)
Forwards Final Deficiency Rept Re Improperly Installed Reactor Coolant Drain
ML19309F096
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 03/03/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19309F096 (1)