ML19309E162

From kanterella
Jump to navigation Jump to search
Ack Receipt of 800229 Final Deficiency Rept Re Undersized Field Welds on Small Piping Installed at Plant.Nrc Will Complete Review of Matter During Future Insp
ML19309E162
Person / Time
Site: Callaway  Ameren icon.png
Issue date: 04/01/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Bryan J
UNION ELECTRIC CO.
References
NUDOCS 8004180486
Download: ML19309E162 (1)


Text

TIC

>* "84 UNITED STATES 9

o, NUCLEAR REGULATORY COMMISSION S

REGloN 111

'I f

'99 ROOSEVELT ROAD f

cLEN ELLYN, fLUNOIS 60137 APR1 E80 Docket No. 50-483 Docket No. 50-486 I

Union Electric Company ATTN:

Mr. John K. Bryan Vice President - Nuclear Post Office Box 149 St. Louis, MO 63166 i

Gentlemen:

Thank you for your final report dated February 29, 1980, pursuant to 10 CFR 50.55(e) regarding undersized field welds on small piping in-stalled at the Callaway Plant. We will complete our review of this matter during a future inspection.

Your cooperation with us is appreciated.

Sincerely, G. FiorelJ1, Chief Reactor Construction and Engineering Support Branch cc:

Mr. W. H. Weber, Manager Nuclear Construction l

Central Files l

Reproduction Unit NRC 20b PDR Local PDR NSIC TIC Regions I & IV Ms. K. Drey Mr. Ronald Fluegge, Utility Division, Missouri Public Service Commission 8004180

- - - - _