_.

-

.

_

-.

o-..

9

..

.

UNITEo STATES

.

NUCLEAR REGULATORY CoMMISSloN

oFFtCE oF INSPECTION ANo ENFORCEMENT

'

RECloN IV

611 RYAN PL AZA oRIVE, SUITE 1000

ARLINGTON. TEXAS 76012

December 3, 1976

Arkansas Power and Light Company

Docket No. 50-313

. ATTN:

Mr. J. D. Phillips

Senior Vice President

,

Sixth and Pine Streets

Pine Bluff, Arkansas 71601

Gentlemen:

Tnank you for your letter of December 1,1976 in response to our letter

and Notice.of Violation dated November 5, 1976. We have no further

questions at this time and we will review your corrective action during

a future-inspection.

(

Sincerely,

j$Wo?

,<

G. L. Madsen, Chief,

Reactor Operations and

Nuclear Support Branch

,

t-

l

b

iA

8004110

E

,

s

.

- - - -

-

- . -

. , _ .

  1. -,.

, -

---_.._y-,.,.r

_.,,_-,,,y

,,,,y,

,..,.,7-_.3m.,%,,-,,

,--,

,,g3

,

--

.

'h.

-

,

_

.-

O' '

Reactor Construction and Operation Branch

Unites States Nuclear Regulatory Commission

March 19, 1977

Page 2

.

AP&L Response

The data sheet used to record the response test,

background and efficiency determination, as per

Procedure H.P. 1602.32, has been predated for each

date of the month.

This should ensure that the

checks are made each day.

In addition, separate

data sheets are now used for the air particulate

standard and smear standard.

The changes stated above will be incorporated into

,

Procedure H.P.

1602.32 to make them a requirement.

In addition, forms H.P. 5.2, 5.3, and 5.10 in

Procedure H.P. 1602.19, " Air Monitoring With Portable

Instruments", will be changed to add a sign-off to

ensure the daily check was performed the same. day

that the sample was counted.

1

The above mentioned procedure modificati$ns will be

(

complhted by May 1,

1977.

,

Very trul

ours

Donald A.

Rueter

Manager, Licensing

<

DAR:LA:ph