ENCLOSURE 1 Arkansas Power and Light Company Arkansas Nuclear One, Unit No. 2 Docket No. 50-368 NOTICE OF VIOLATION Based on the results of an NRC inspection conducted during the period of December 22, 1979 through January 21, 1980, it appears that certain of your activities were not conducted in full compliance with NRC regulations and the conditions of your license, as indicated below:

Technical Specification 6.8.1 requires that " Written procedures shall be established, implemented, and maintained covering.

.. a.

The applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33.

As required in paragraph I of Appendix A to Regulatory Guide 1.33, Administrative Procedure 1005.01, " Administrative Controls Manual,"

has been established.

Section 5.9 of this procedures states in part, " Procedures in the Master plant Manual are to be followed exactly and completely, provided that by so doing an immediate hazard to personnel or plant equipment is not created."

Procedure 2.800.01, " Power Ascension Test," Appendix DD, step 2.3 states, " Prior to the trip of any CEA, the CEACs shall be removed from service in order to avoid adverse CEAC penalty factor effects which may cause a reactor trip during the testing.

The CEACs shall be reinstated to service immediately following return of the dropped CEA back to the fully withdrawn position."

Step 7.11 states, "Following the return of the dropped CEA to the fully withdrawn position, perform Attachment DD-2 when the COLSS Azimuthal Tilt (CV9008) has decreased below 0.04," and-Attachment DD-2, step 5.0 states, " Return all CEAC's to operation and take all CPC channels out of CEANOP per OP 2105.01, unless further testing requires them to remain in CEANOP."

Contrary to the above, in January, 1980, the licensee failed to return the CEAC's to operation after returning the dropped CEA to the fully withdrawn position and after COLSS Azimulthal Tilt decreased below 0.04.

Further testing did not require the CEAC's to remain in CEANOP.

This is an infraction.

(50-368/80-02-01)

(