ML19309B952
| ML19309B952 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 03/10/1980 |
| From: | Ippolito T Office of Nuclear Reactor Regulation |
| To: | Pilant J NEBRASKA PUBLIC POWER DISTRICT |
| References | |
| TAC-10079, NUDOCS 8004070390 | |
| Download: ML19309B952 (3) | |
Text
_
TE R <4
((jT,,....,)*g UNITED STATES g
NUCLEAR REGULATORY COMMISSION
%"/}E 3'
WASHINGTON, D, C. 20556
\\.
March 10, 1980 Docket No. 50-298 Mr. J. M. Pflant, Director Licensing & Quality Assurance Nebraska Public Power District P. O. Box 499 Columbus, Nebraska 68601
Dear Mr. Pilant:
During the last several years, data tave begun to indicate that the fission gas release rate from LWR fue? pellets is increased (enhanced) with burnup.
Many of the current fuet performance analyses do not consider the i@act of burnup release on safety.
By letters dated November 23, 1976, the NRC staff requested all LWR licensees to assess the higher fission gas release for fuei burnups above 20,000 Megawatt-day per metric ton (MWD /T).
Also, by NRC staff letter dated January 18, 1978, all U. S. LWR fuel suppliers were requested to revise their fuel performance analyses to include the enhancement of fission gas release at higher burnups.
All responses to the November 23, 1976 latters have been reviewed.
We have concluded that no innediate licensirig action is required for operat-ing reactors.
This conclusion is valid f or typical reported LWR fuel bundle and batch burnups.
Any extension of these burnups or other fac-tors which significantly affect fission gas release, LOCA PCT or fuel rod internal pressure is outside the scope of the conclusion.
The effect of enhanced release on BWR ECCS performance has been discussed with General Electric (GE). GE has pointed out that because of opera-tional restrictions and physical limitations, the LOCA analysis is not limiting in high burnup fuel (25,000 WD/T).
High burnup fuel generally cannot achieve linear power densities near the LOCA limit early in cycle.
The limiting. fuel bundle is usually in its second cycle of reactor opera-tions where burnup levels are below =20,000 WD/T. ~ t, ate in a BWR fuel cycle, there is less axial power peaking reducing the feasibility for any given axial location to exceed LOCA linear power density limits, and the fuel bundle power is generally limited by MCPR considarations.
- Thus, it is unlikely that a high burnup bundle can exceed the ECCS performance criteria in case of a LOCA. The argument is appropriate for Exxon fuel bundle design also based on the review of Exxon analyses for operating BWRs.
Therefore, no immediate licensing action is necessary or, operating BWRs.
D 04 opp 3N
Mr. J. M. Pflant Inasmuch as you and/or the staff will be evaluating all future reloads against fuel vendors' revised fuel performance codes which provide for increase in fission gas release at higher burnups, we consider this a satisfactory resolution of this concern.
Sincerely, A -
Thomas /. Ippolito, Chief Operating Reactors Branch #3 Division of Operating Reactors cc:
See next page 6
i 4
l l
l t
Mr. J. M. Pilant Nebraska Public Power District
-3 I
cc:
Mr. G. D. Watson, General Counsel Nebraska Public Power District P. O. Box 499 Columbus, Nebraska 68601 Mr. Arthur C. Gehr, Attorney Snell & Wilmer 3100 Valley Center Phoenix, Arizona 85073 Cooper Nuclear Station ATTN: Mr. L. Lessor Station Superintendent P. O. Box 98 Brownville, Nebraska 68321 Auburn Public Library 118 - 15th Street Auburn, Nebraska 68305 4
l T