Forwards IE Insp Rept 70-1151/80-02 on 800124-25 & Notice of Violation
ML19309B361
Person / Time
Site: Westinghouse
Issue date: 02/08/1980
From: Kenna W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Damore M
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML19309B362 List:
References
NUDOCS 8004040080
Download: ML19309B361 (2)


Text

Wa reo%'o, J

8 UNITED STATES

[ igg 1*

NUCLEAR REGULATORY COMMISSION 7&//4;$/

g g@,/
:/

s REGION 11 o, p* Q 4 f m

101 MARIETTA ST., N.W., SUITE 3:00 ATLANTA, G EORGIA 30303 In Reply Refer To:

FEB -81980 RII:GPC 70-1151/80-2 Westinghouse Electric Corporation ATTN:

M. D'Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, S C 29205 Gentlemen:

This refers to the inspection conducted by G. P. Coryell of this office on January 24-25, 1980, of activities authorized by NRC SNM-1107 for the Columbia Nuclear Fuel facility, and to the discussion of our findings held with M. D'Amore at the conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in the enclosed inspection report. Within these areas, the inspeccion consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

We have examined actions you have taken with regard to previously identified enforcement matters. These are discussed in the enclosed inspection report.

During the inspection it was found that certain activities under your license appear to be in noncomplianc3 t.:th NRC requirements.

This item and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.

Corrective actions to prevent recurrence were completed prior to the conclusion of this inspection; therefore, a reply is not requested.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

If this 9

report contains any information that you (or your contractor) believe to be proprietary, i.

2-necessary that you make a written application within 20 days to this office to withhold such information from public disclosure.

Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

8 0 0 4 0 4 00go

i, FEB -81980 Westinghouse Electric Corporation,

Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely,

^

j,/

L p

. B. Ken'op, Chief afeguarM Branch

Enclosures:

1.

Appendix A, Notice of Violation 2.

Inspection Report No. 70-1151/80-2 e