- - __

VrHOINiA ELECTHIC AND POW Elf COM PA NY Ricnxxown,Vinoxx xA cac61 April 2, 1980 Mr. Harold R. Denton, Director Serial No. 288 Office of Nuclear Reactor Regulation LQA/WRM:rab Attn:

Mr. O. D. Parr, Chief Light Water Reactors Branch No. 3 Docket No. 50-339 Division of Project Management U.. S. Nuclear Regulatory Commission Washing ~.on, D.C.

20555

Dear Mr. Denton:

In order to allow the Staff to begin review of the procedures for the special test program for North Anna 2, we have enclosed seven of the nine test procedures outlined in our previous letter dated March 19, 1980 (Serial No. 251).

The procedures enclosed are as follows:

.l.

Cooldown Capability of the CVCS 2.

Forced Circulation Cooldown 3.

Natural Circulation Test 4.

Natural Ci'

!ation With Simulated Loss of Offsite AC ower 5.

Natural Circulation With Loss of Pressurizer Heaters 6.

Effect of Steam Generator Secondary Side Isolation On Natural Circulation 7.

Natural Circulation At Reduced Pressure.

The safety evaluation, the two remaining test procedures, and revisions resulting from your advance resiew of the seven procedures enclosed will be provided later.

Very truly yours, B. R.

ylvia Manager-Nuclear Operations and Maintenance Attachment ec:

Mr. James P. O'Reilly Of fice of Inspection and Enforcement Region II 8004030 la 3

,