ML19309B131
| ML19309B131 | |
| Person / Time | |
|---|---|
| Site: | Midland |
| Issue date: | 03/19/1980 |
| From: | Fiorelli G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Howell S CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| References | |
| NUDOCS 8004030177 | |
| Download: ML19309B131 (1) | |
Text
j
,,n..--.
m n i a n a i ei i-v MAR 19 G80 Docket No. 50-329 Docket No. 50-330 Consumers Power Company ATTN:
Mr. Stephen H. Howell Vice President 1945 West Parnall Road Jackson, MI 49201 Gentlemen:
Thank you for your interim report dated March 3,1980, pursuant to 10 CFR 50.55(e) regarding Reactor Vessel Broken Anchor Bolt. We will complete our review of this matter upon receipt of your final report.
Your cooperation with us is appreciated.
Sincerely, G. Fiorelli, Chief Reactor Construction and Engineering Support Branch cc w/ltr dtd 3/3/80:
Central Files Reproduction Unit NRC 20b PDR NSIC RII /I RIII RITI 42, MW 9-Vandel jp Knop ',
Er 3/11/80 y
8004000[7 7
CORSumBIS s
Power h'
Stephen H. Howell Senior Vsce 14esident
\\
Ger. oral Offices: 1945 West Parnell Road, Jackson, Michigan 49201 * (517) 788-0453 March 3, 1980 Howe-51-80 Pe J G Keppler, Regional Director Office of Inspection and Enforcement US Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 1
MIDLAND NUCLEAR PLANT UNIT NO 1, DOCKET NO 50-329 UNIT NO 2, DOCi:ET NO 50-330 UNIT NO 1, REACTOR VESSEL BROKEN ANCHOR BOLT
References:
Letter, S H Howell to J G Keppler; Midland Nuclear Plant; Unit No 1, Docket No 50-329; Unit No 2, Docket No 50-330; Unit No 1 Reactor Vessel Broken Anchor Bolt;
- 1) Howe-311-79; dated December Ih,1979
- 2) Hove-267-79; dated October 12, 1979 i
This letter, as were the referenced letters, is an interim 50.55(e) report concerning broken anchor bolts in the Unit 1 reactor vessel support skirt flange. The enclesure to this letter provides a status of the actions being taken to resolve this condition.
Another report, either interim or final, vill "be sent on or before May 1, 1980.
3 WRB/1r
Enclosure:
Broken Reactor Vessel Anchor Bolt in Unit 1 Status Report, MCAR-37. Interim Report #1, dated February 20, 1980.
CC: Director of Office of Inspectic Att Mr Victor Stallo, USNRC (1 DUPLICATE DOCUMENT Director, Office of Management Infomation & Program Control, Entire document previously entered into system under:
ANO ${]h~ ~
$0fOf(
Q
-M/
No. of pages:
M
...c.,....,.
.