s

,["%

umiso:Taras p

$g NUCLEAR REGULATORY COMMISSION 3

.g wAswiwarow o.c. noses os.,*..../

g SACRAMENTO MUNICIPAL UTILITY DISTRICT DOCKET NO. 50-312 RANCHO SECO NUCLEAR GENERATING STATION AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 8 License No. DPR-54 I

1.

The Nuclear Regulatory Comission (the Comission) has found that:

A*

The application for amendment by Sacramento Municipal Utility District (the licensee) dated October 4,1976, complies with the standards and re as amended (the Act)quirements of the Atomic Energy Act of 1954,

, and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in confomity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Speciftcations as indicatet-' in the attachment to this license amendment.

1 l

8004010 W 4

2-3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY C0!HISSION m

Robert W. Reid, Chief Operating Reac. tors Branch #4 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance: December 23, 1976 e

WS 9

~

ATTACHMENT TO LICENSE AMENDMENT NO. 8 FACILITY OPERATING LICENSE NO. DPR-54 DOCKET NO. 50-312 Revise Appendix A Technical Specifications as follows:

Remove Figures Insert Figures 3.5.2-1 3.5.2-1 3.5.2-2 3.5.2-2 l

l t-

m

+

100 @.iii 02

3 i:i1

" POWER LEVEL 180.2, I

t 197.8, 90 CUTOFF 92 92

' ~ ^ ' '

174.1, 82

'200, 82 80

.
:::i:

3 RESTRICTED REGION 70

@i:i l

a
<u 60 ib :
e :
u i u 5::.
i:!

"" i"P$

50

=:::

e c::::
o :a:.:

E

. z e.:.

u I

.i 122.3, 43 PERMISSIBLE

"" : a U^iii a

1 40 OPERATING REGION

  • :: :<z iii~i N

N

= H.:::

n

. un...

..]

N z:::

m:::,,,",.... ! E 5:

li!]

m.o 30

~

M

!!1 h 20 M:i o

i:5 i:}

80, 15

!j!{

10 4:i:

l

!O N 100 S

0 40 60 80 120 140 160 180 200 O

20 ROD INDEX, % WITHDRAWN 0

25 50 75 100 I

t t

I f

I GROUP 6 & 7 0

25 50 75.

100 l

I I

1 1

1 i

GROUP S I

l i

1. Rod index is the percentage su::: of the withdrawal of control rod groups 5, 6 and 7.
2. The restrictions on rod position are in effect after 240 EFPD.

)

l

3. Reactor shall not be critical for group 5 index below 49%.

ROD POSITION LIMITS Figure 3.5.2-1 AmendmentNo.1,/8

110 E'

-15.3.102

+8.0,102 100 g

g

-15.6,92

+6.5,92

-23.0,82/

80 Permissible

+ 14.5,73 E

Operating Range N

N 60 r

H 3

A 4

-34.4.43

, 19.8,40

+

40 20 l

0

-40

-30

-20

-10 0

10 20 Core imbalance, %

7 1.

THE LIMITS ARE IN EFFECT OPERATIONAL POWER IMBALANCE ENVELOPE AFTER 240 EFPD.

Figure 3 5.2-2 RANCHO SECO UNIT I TECHNICAL SPECIFICATIONS Proposed Amendment No. 44 k,

^=ad""' "

$/. 8

_