Forwards LER 80-035/99X-0
Date released: 11/19/2019 Download: ML19309A908


LER 80-035/99X-0:on 800313,Westinghouse Informed Util of Potential for Supplied Control Rod Guide Tube Support Pins to Break Due to Stress Corrosion Cracking.Caused by Low Solution Heat Treatment Temp
ML19309A909
Person / Time
Site: North Anna 
Issue date: 03/27/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19309A909 (2)
Forwards LER 80-035/99X-0
ML19309A907
Person / Time
Site: North Anna 
Issue date: 03/28/1980
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19309A907 (1)