05000318/LER-1980-015-03, /03L-0:on 800227,during Maint,Control Element Assembly 44 Dropped Into Core.Caused by Electrician Accidentally Grounding Prime 15 Volt Power Supply.Faulty Backup Power Supply Was Changed

From kanterella
(Redirected from ML19309A829)
Jump to navigation Jump to search
/03L-0:on 800227,during Maint,Control Element Assembly 44 Dropped Into Core.Caused by Electrician Accidentally Grounding Prime 15 Volt Power Supply.Faulty Backup Power Supply Was Changed
ML19309A829
Person / Time
Site: Calvert Cliffs 
Issue date: 03/25/1980
From: Bauer E, Lagiewski J
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19309A819 List:
References
LER-80-015-03L, LER-80-15-3L, NUDOCS 8004010388
Download: ML19309A829 (2)


LER-1980-015, /03L-0:on 800227,during Maint,Control Element Assembly 44 Dropped Into Core.Caused by Electrician Accidentally Grounding Prime 15 Volt Power Supply.Faulty Backup Power Supply Was Changed
Event date:
Report date:
3181980015R03 - NRC Website

text

__

(7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lOTi1 h lo Ic Ic h 12 l@l o i n i _ l n i n i n I nj n I _ i n i n l@l 41, li I, I, l@l I

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 26 26 LICENSE TYPE JO 57 CA1 68 CON'T I o I 1 lh 3 U l L l@l -l 5 l 010 l 0 l 3 l 1 l 8 l@l o I 7 l ? I 7 l R l n l@l n 1 t l 9 l c; I o I n l@

C

?

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74

?S REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h I o I a i IDurino maintenance, at 1303. control element assor,hly (CFA) da drnnned intn the Io i3l l core. Per T.S. 3.1.3.1.f reactor power was reduced to,< 70% by 1345 CFA da l

I o 14j % withdrawn back to its aroup at 1422.

All other CEA's remained nnprahin.

I l o i s i IFo110 wing the dropped CEA at 1615. azimuthal cower tilt (Toi was fnnnd tn ha l

IoIsI >.030.

Per T.S. 3.2.4. total clanar radial ceakino factnr and tntal intanratad I

lO l 7 l Iradial peakino factor were verified to be within ifmits.

To was reduced tn <.030 I

i o i s i lat 1905.

LER's 80-12 (U-1) & 80-10 (U-2) describe similar events.

I E

CODE SUSCO E COMPONENT CODE SUSCODE SU E

lo191 1 R l B l@ W@ LC_J @ l I l til S l Tl R l U l@ l p l@ [Z_j @

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LE RiR EVENT YEAR REPORT NO.

CODE TYPE NO.

@ yug"O l 8101 l-l 1 01 11 51 LdJ lof3i LLJ I-I LaJ aE

_ 21 22 23 24 26 27 28 29 00 31 32 KN AC ON ONP NT M

HOURS 22 38 IT POR 8.

S PPLIE MANUFACTURER lCl@[li_J@

l Bl@

[Z_J@

l0101Ol81 l Yl@

l Y l@

l fil@

l Pl 311141@

i 33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS t li 101 [t was found that the back-uo 15V onwar sunnly fnr CrA ad had dnuninnad 2 1 m, I

I ii iti voltace outout on its teminals.

Durina the course nf changinn not +bo h=%p it #2i power supply, the prime 15V oower supoly was accident 1v orounded by the electrician I

i1 #3i pausino CEA 44 to drop. The faulty back-uo power sucolv was chanoe_d out and CEA 44 i

,i i4i pas raised without further mishap.

I 7

8 9 80 STA

% POWER OTHER STATUS DIS O RY DISCOVERY DESCRIPTION 11 15IlEl@ l0191Ol@l ilA l

l A l@l Operator Observation l

ACTIVITY CO TENT RFLEASF AMOUNT OF ACTIVITY LOCATION OF RELEASE ft I 6 I [.Z_] @D OF PELEASELZj@l NA I

I NA I

PERSONNEt ExPOSOES NUMBER TYPE

DESCRIPTION

15171 b b l o l@LZ_J@l NA

~ -

- l

' PERSONNEt,N;UViES NUMBER

DESCRIPTION

i 11 la l l_010 l o l@l NA l

7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYPE

DESCRIPTION

D 8 00401r-9 l

li 191 U@l na 7

8 9 10 80 l

flA l

[tlllll1Iill lj l a l o l I t4 U@ DESCRIPTION ISSUE l

7 8 9 10 68 69 80 3 J. S. I.aaiewski/E. R. Bauer l3011760 a747f4728 NAME OF PREPARER PsONE:

o l

LER NO.

80-15/3L DOCKET NO.

50-318 EVENT DATE 02/27/80 REPORT DATE 03/25/80 ATTACHMENT CAUSE DESCRIPTION AND CORRECTIVE ACTIONS:

(CONTINUED)

The technician was verbally cautioned to use extra cr.ve and caution when dealing with these power supplies.

9 I

s e

A 5

e 6

D