Concurs W/Applicant Proposed Max & Min Stillwater Levels Resulting from PMH Passage & Analysis That Flood Protection Level Sufficient to Withstand Max Limit of Wave Runup Coincident W/Hurricane Induced Water Levels
ML19308E060
Person / Time
Site: Crystal River 
Issue date: 12/20/1973
From: Stevens R
ARMY, DEPT. OF, CORPS OF ENGINEERS
To: Harold Denton
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8003200792
Download: ML19308E060 (2)


Text

c-

- m u w.

a m

'+.

.I

.- u-

-.. - ~

- m.. >

'._ _ _ ~.

a 50-302 C

(,^s) g, jyff.%

DEPARTMENT Oi -THE ARMY

.u,f #.. m./ n G -

V COASTA1. ENGINEERING RESEARCH CENTER

. g I*Q.<* [s e}-t, KINGMAN BUILDING S...:Q f i.'/

FORT BELVOIR. VIRGINI A 22C60

' M';t-%j$

CEIEN-DE 2 0 CEC 573

~

  • ~- 3 '.1.,

/Y n

h

<:ra Mr. Harold R. Denton

' 6ff9 N-

' h, ** Q,.h ' Ik2 Assistant Director for Site Safety

, J/

.'8 U. S. ' Atomic Energy Commission

~!

Washington, D.C.

20545

. W** ' C.

~

$., 's'a. c f V

n e3 s,y s

[

j

' f.,.

".;\\ 7 /

g ". ;,

,/

Decr Mr. Denton:

Reference is made to your letter of 28 August 1967 initiating review of Docket No. 50-302, the Florida Power Corporation's, Crystal River Nuclear Generating Plant, Unit No. 3 including Amendments thereto through No. 34.

t In accordance with cur arran2ements, an engineer on ny staff has reviewed pertinent information in the report leading to the establishnent of the maximum and ninimua design water levels for the Crystal River Plant.

This review covered the applicant's deternination of the surge associated with the occurrence of the Fro'oable."axinua Hurricane at the site as well as wind-wave generation, wave runup and overtopping also associated there;;ith.

/

It is his opinion, with which I concur, that the maxi =un and mini.um still-water levcis proposed by the applicant as the result of the passage of the Probable Maximua Eurricane are El. 33.4 feet, MLW datua (E1.121.4 ft.,

plant datum) and El. -9.0 feet, MLW datum- (El. 79.0 ft., plant datua) respectively.

I also concur with the applicant's analysis that a' ficod protection level

(

of E1. 41.0 feet, MLW datua (El.129.0 ft.', plant datum) for essential l

facilities is sufficient to withstand the maximun linit of tave runup I

coincident. with the hurricane induced water levels.

l

)

1 t

I l