LTR 3 ENCL 43 FORWARDING BAW-1490 REPT ENTITLED: " CRYSTAL RIVER UNIT 3.
LICENSING CONSIDERATIONS FOR CONTINUED CYCLE 1 OPERATION WITHOUT GURNABLE POISON ROD ASSEMBLIES", DTD MAY 1978, JUSTIFYING CONTINUED OPERATION THROUGH THE REMAINDER OF THE FIRST CYCLE WITH ALL DURN ABLG. PoisoM 4
P o.b 1 5JerrotfES REMOVE D y::Ec g t ge e q, (w @)
REVIEWER INITIAL:
XJM PLANT NAME: CRYSTAL RIVER #3 DISTRIBUTOR INITIALI
- o************** DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ******************
INCIDENT REPORTS (DISTRIEUTION CODE AOO2)
ENCL FOR ACTION:
BR CHTFF NM4 INTERNAL:
FILE **W/ENCff NRC PDR**W/ ENCL i._x x w/ z LNCL Pttfibimen' ' 'T "S N -SYOTEMC EP~ - ~ 2.WCL E N ?.V-PLAN LR r ~ 't Neuuur7tWEC$twwW/ENet-EEB**W/ ENCL Adia-Ed*--m4G* *' '.'E N O L P
HANAUER**W/ ENCL
.AD i On i La,. ~.
E"'?""U P t AD FOR OPER TECH **W/ ENCL REJr T:T C ;~
L.,m/CNCL ENGINEERING BR**W/ ENCL vpq_;
<; _., ;;;,, 4/ ENCL
,G_EUd ?OLLP.'2.'_"N~:
g qgt L
POWCM., r " r: cot-
. m i / A c. w m_.
RO. Ac.rCR.- 5 MM EE O EXTERNAL:
LPDR'S coee F8E5:cf914#8-et. w/M CRYSTAL RIVER. FL**W/ ENCL TIC **W/ ENCL NSIC**W/ ENCL j, Mg(oooGM W/G4 W'
ACRS CAT B**W/16 ENCL Er-ec oe wr 'ThewSYS 06LD L.TQ..
4-l IRE 40
- ' ^ ' ~ ^ ^ ^ ^ ^
DISTRIDUTION:
LTR W ENCL 4G-CONTROL NBR-SIZE: 2P+36P
- h****
- o*******************************
THE END
/
8003200 O 5 g
i
e
.g u
~
,C'i
'W Florida
~
Power C O N PO 4 A f EON June 2, 1978 Mr. Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D.C. 20555
~
Subject:
Crystal River Unit No. 3 Docket No. 50-302 Operating License No. DPR-72 Florida Power Corporation
Dear Sir:
Enclosed are forty-three (43) copies of the report BAW-1490, Crystal River Unit 3, Licensing Considerations for Continued Cycle 1 Operation Without Burnable Poison Rod Assemblies.
This report justifies the continued operation of Crystal River No. 3 through the remainder of the first cycle with all burnable poison rod assemblies removed from the core. Orifice rod assemblies will be utilized in those fuel assemblies previously containing burnable poison rod assemblies except for eight locations. These eight locations correspond to the two fuel assemblies from which burnable poison rod assemblies previously escaped and their six symmetrical locations.
Section 6, Proposed Modifications to Technical Specifications, of the enclosed report is included for completeness of information only. A formal request for Technical Specification changes will be filed under separate letter accompanied by the appropriate licensing fee.
It is our belief that continued operation of Crystal River Unit No. 3 with the burnable poison rod assemblies removed represents no substantial safety hazard or unresolved safety concerns.
Please advise if further discussions of the enclosed report is desired.
Yours very truly, FLORIDA POWER CORPORATION h
A. (f. Ormston Vice President AJ0/QBD/hw 4/20 i[9 M z,)
P File: 3-0-3-a-3 General Office 32o1 in ny founn street sco:n. P O Box 14042. st Petersburg Ficnca 33733 813 - 866-5151
~
~ STATE OF FLORIDA COUNTY OF PINELLAS 1
A. J..Ormston, Vice President for Florida Power Corporation, states that he is authorized 'on the part of said company to sign and file with the Nuclear Regulatory Consnission the iniorma~ tion attached hereto;
~
and that all such statements made and matters set forth therein are i
true and correct to the best of his knowledge, information and belief.
A/ J. Ormston Subscribed and sworn to before me, a Notary Public in and for the State and County above-named, this 2nd day of June,1978.
/.
Notary Public Notary Public, State of Florida at Large,
~
My Commission Expires: July 25,1980
'