ML19308A295

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-02, Pipe Support Base Plate Design Using Concrete Expansion Anchor Bolts
ML19308A295
Person / Time
Site: Rancho Seco
Issue date: 03/08/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
References
NUDOCS 7903150067
Download: ML19308A295 (1)


Text

.

U j.O 4,

UNITED STATES

[3,,

g/t NUCLEAR REGULATORY COMMisslOrj REGION V g

' f /

d SUITE 202, W ALNUT C HEEK PLAZ A Dj 6

1930 f4. C ALIF O H NI A D OULEVA R D 4

o a' 9

9

  • eee*

W alt 4 UT C R EE K, C AllF OR F41 A 94596 March 8,1979 Docket flo. 50-312 Sacramento Municipal Utility District P. O. Box 15830 Sacramento, California 95813 Attention: Mr. John J. Mattimoe Assistant General flanager Gentlemen:

The enclosed IE Bulletin !!o. 79-02 is forwarded to you for action. A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, hlbm4 R. H. Engelken Director

Enclosures:

1.

IE Bulletin No. 79-02 2.

List of IE Bulletins Issued in the past 12 months cc w/ enclosures:

R. J. Rodriguez, SMUD L. G. Schwieger, SMUD 7903150067

UNITED STATES l'UCLEAR REGULATORY COMMISSION 0FFICE OF IflSPECTION AND ENFORCEMEiiT WASHINGTON, D.C.

20555 March 8, 1979 IE Bulletin No. 79-02 PIPE SUPPORT BASE PLATE DESIGNS USING CONCRETE EXPANSION ANCHOR BOLTS Description of Circumstances:

While performing inservice inspections during a March-April 1978 refueling outage at Millstone Unit 1, structural failures of piping supports for safety equipment were observed by the licensee.

Subsequent licensee inspections of undamaged supports showed a large percentage of the concrete anchor bolts were not tightened properly.

Deficiency reports, in accordance with 10 CFR 50.55(e), filed by Long Island Lighting Company on Shoreham Unit 1, indicate that design of base plates using rigid plate assumptions has resulted in underestima-tion of loads on some anchor bolts.

Initial investigation indicated that nearly fifty percent of the base plates could not be assumed to behave as rigid plates.

In addition, licensee inspection of anchor bolt installations at Shoreham has shown over fifty percent of the bolt installations to be deficient.

Vendor Inspection Audits by MRC at Architect Engineering firms have shown a wide range of design practices and installation procedures which have been employed for the use of concrete expansion anchors.

The current trends in the industry are toward more rigorous controln a7d verifica-tion of the installation of the bolts.

The data available on dynamic testing of the concrete expansien anchors show fatigue failures can occur at loads substantially below the bolt static capacities due to material imperfections or notch type stress risers.

The data also show low cycle dynamic failures at loads below the bolt static capacities due to joint slippage.

Action to be Taken by Licensees and Permit Holders:

For pipe support base plates that use concrete expansion anchor bolts in Seismic Category I systens as defined by Regulatory Guide 1.29, " Seismic Design Classification" Revision 1, dated August 1973 or as defined in the applicable FSAR.

1.

Verify that pipe support base plate flexibility was accounted for in the calculation of anchor bolt loads.

In lieu of supporting analysis justifying the assumption of rigidity, the base plates b