Text
__
O UNITED STATES G
A j
NUCLEAR REGULATORY COMMISSION y
3
- y WASHINGTON, D. C. 20665
(.D THE TOLEDO EDISON COMPANY o
AND THE CLEVELAND ELECTRIC ILLUMINATING COMPANY DOCXET NO. 50-346 r
DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendnent No, 23 License No. NPF-3 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by The Toledo Edison Company and l
The Cleveland Electric Illuminating Company (the licensees) dated i
January 10, 1980, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The facility will operate in confomity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (1) that the activities authorized
~'
by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and 1
E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable mquirements have been satisfied.
I l
8004150 l' o
i-;
! 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-3 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 23. are hereby incorporated in the license. The Toledo Edison Company shall operate the facility in accordance with the Technical Specifications.
l 3.
This licence amendment is effective as of the date of its i
issuance.
I FOR THE NUCLEAR REGULATORY COPHISSION M'
g R66ert W. Reid, Chief Operating Reactors Branch #4 l
Division of Operating Reactors i
Attachment:
Changes to the Technical Specifications Date of Issuance:
.iarch 27,1980
=
r ATTACHMENT TO LICENSE AMENDMENT NO.
23 FACILITY OPERATING LICENSE NO. NPF-3 DOCKET fi0. 50-346 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page as indicated. The revised page is identified by Amendment number and contains vertical lines, indicating the area of change.
Page 3/4 4-31 l
u
REACTOR COOLANT SYSTEM SURVEILLANCE REOUIREMENTS (Continued) b.
Each internals vent valve shall be demonstrated OPERABLE at least once per 18 months during shutdown,* by:
1.
Verifying throuch visual inspection that the valve body and valve disc exhibit no abnormal degradation, 2.
Verifying the valve is not stuck in an open position, i
and 3.
Verifying through manual actuation that the valve is fully open when a force of < 400 lbs. is applied vertically upward.
f l
i i
- Performance of this Surveillance Requirement may be deferred until
'May 30, 1980 to coincide with the first refueling outage.
l l
DAVIS-BESSE, UNIT 1 3/4 4-31 Amendment No. 23
-