APPENDIX A NOTICE OF VIOLATION Tennessee Valley Authority License No.CPPR-153 Hartsville Nuclear Plant Based on the NRC inspection December 17-19, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indi-cated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by Criterion XVII of Appendix B to 10 CFR 50, and implemented by PSAR Section 17.1A.17, " Sufficient records shall be maintained to furnish evidence of activities affecting quality."

Contrary to the above, records on pour number B2R-1C and ID are inaccurate in that they show the water content varied up to 25 percent above the amount specified in the design mix. However, the slump and strength results were within design requirements. The error in recorded water data produces records which are unsatisfactory for the intended purpose.

This is a deficiency.

e o'3'190'Ih' L