ML19305A921

From kanterella
Jump to navigation Jump to search
Forwards LER 80-029/03L-0
Date released: 11/15/2019 Download: ML19305A921


LER 80-029/03L-0:800213,following Reactor Scram,Suppression Pool Level Exceeded 27 Inches Due to Lifting of Three Reliefs & Running of HPCI & Rcic.Caused by Burned Contacts on Relay B21-K59 in Opening Logic for FO49 Valve
ML19305A928
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 03/11/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19305A928 (1)
Forwards LER 80-029/03L-0
ML19305A920
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 03/11/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19305A920 (1)