ML19296C556

From kanterella
Jump to navigation Jump to search
Forwards LER 80-007/03L-0
Date released: 11/06/2019 Download: ML19296C556


LER 80-007/03L-0:on 800125,while Performing SI 4.2.A-16, Calibr Reactor Bldg Isolation &/Or Logic Timers,B Logic Channel Did Not Isolate.Caused by Intermittent Sticking of Relay R1B Resulting in Time Delay Contacts Being Closed
ML19296C558
Person / Time
Site: Browns Ferry 
Issue date: 02/22/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19296C558 (2)
Forwards LER 80-007/03L-0
ML19296C555
Person / Time
Site: Browns Ferry 
Issue date: 02/22/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19296C555 (1)