ML19296B938

From kanterella
Jump to navigation Jump to search
Forwards LER 80-001/03L-0
Date released: 11/06/2019 Download: ML19296B938


LER 80-001/03L-0:on 800108,while Performing Relief Valve Setpoint Check,Reactor Vessel 1105A Actuated at 1,600 Psig & Reactor Vessel 1105B Actuated at 1,500 Psig.Possibly Caused by Setpoint Drift.Valves Will Be Repaired
ML19296B947
Person / Time
Site: Quad Cities 
Issue date: 02/07/1980
From: Vahrenwald J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19296B947 (1)
Forwards LER 80-001/03L-0
ML19296B937
Person / Time
Site: Quad Cities 
Issue date: 02/07/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19296B937 (1)