k "fl

y...~,%

4 UNITED STATES 8 'y ) nc ' h NUCLEAR REGULATORY COMMISSION 3.' s C

WASH'NGTON, D. C. 20555 s

s,...../

JAN 3 01980 Docket Nos. 50-373 and 50-374 Mr. D. Louis Peoples Director of Nuclear Licensing Commonwealth Edison Company P. O. Box 767 Chicago, Illinois 60690

Dear Mr. Peoples:

SUBJECT:

REQUEST FOR IflFORMATION CONCERMING THE STAFF'S DEVELOPMENT OF GENERIC GUIDELINES FOR BWR SACRIFICIAL SHIELD COMPARTMENTS, LA SALLE COUNTY STATION, UNITS 1 & 2 In a telecon held on December 6,1979, with Mr. L. DelGeorge of your staff, we indicated that a program has been recently instituted to develop generic guidelines for all boiling water reactor sacrificial shield compartments and that we require certain detailed information on the reactor cavity.

To aid in obtaining realistic infomation on actual plant designs, we are requesting this type of information from several applicants including La Salle. Analysis of the infomation will be performed by our contract personnel at the Los Alamos Scientific Laboratory.

The requested information should be in the form of drawings.

The drawings should be in sufficient detail to show physical geometry, flow paths, and relative location for the following components:

(1) Reactor vessel nozzel and piping, (2) Reactor vessel support; (3)

Instrumentation tubes (e.g., neutron detectors);

(4) Shielding devices (e.g., shield blocks, plugs, shield ring or tank);

(5) Variations in reactor vessel diameters; 8002100 'l }

)

t 9

Mr. D. Louis Peoples JM 3 0 g (6) Variations in profile of primary shield wall, and (7) Shield wall penetration entrance and exits.

Your assistance in expediting your response to the above request would be appreciated.

Sincerely, b.k lan D. Parr, Chief Light Water Reactors Branch No. 3 Division of Project Management cc:

Richard E. Powell, Esq.

Isham, Lincoln & Beale One First National Plaza Suite 2400 Chicago, Illinois 60670 Dean Hansell, Esq.

Assistant Attorney General State of Illinois 188 West Randolph Street Suite 2315 Chicago, Illinois 60601 Mr. Roger Walker, Resident Inspector U. S. Nuclear R:.gulatory Conmission P. O. Box 737 Streator, Illinois 61364