MONTHYEARML18347A2092018-11-30030 November 2018 Kansas State Univ., Manhattan - Technical Specifications and Safety Analysis Report Changes Related to License Amendment Request No. 18 Project stage: Request ML19128A3422019-06-0505 June 2019 Kansas State University, Request for Additional Information Related to License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: RAI ML19248C8342019-09-18018 September 2019 Kansas State University, Summary of Teleconference Related to License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: Meeting ML19295D7272019-10-0707 October 2019 Kansas State University - Response to 06/05/2019 Request for Additional Information, and Teleconferences Summary Project stage: Meeting ML19290H5162019-10-0808 October 2019 Kansas State University, Electronic Mail Providing Minor Clarification on October 7, 2019 Letter Project stage: Request ML19290H5932019-10-24024 October 2019 Kansas State University, Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements, and Acknowledgement of Operation Project stage: RAI L-19-288, Request to Revise the Perry Nuclear Power Plant (PNPP) Fire Protection Program Licensing Basis2019-12-18018 December 2019 Request to Revise the Perry Nuclear Power Plant (PNPP) Fire Protection Program Licensing Basis Project stage: Request ML20013F6802020-01-0707 January 2020 Kansas State Univ., Request for Additional Information (Acc. Fl MU9128A34~) Response Time Extension Project stage: Request ML20008D3522020-01-13013 January 2020 Kansas State University, Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: RAI ML20083G1942020-03-0909 March 2020 Kansas State University - Request for Additional Information (Acc. ML19128A342) Response Time Extension Project stage: Request ML20070H6742020-03-30030 March 2020 Kansas State University, Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: RAI ML20154K7002020-07-0909 July 2020 Issuance of Amendment No. 190 Regarding Fire Protection Program Licensing Basis Project stage: Approval ML20253A2352020-10-0505 October 2020 Kansas State University, Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: RAI ML20366A0462020-12-0808 December 2020 Kansas State University, Response to Request for Additional Information (Acc. ML19128A342) Re Response Time Extension Project stage: Response to RAI ML21013A5402021-01-26026 January 2021 Kansas State University, Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Weight Percent Uranium Fuel Elements Project stage: RAI ML21105A4852021-03-0808 March 2021 Kansas State Univ., Response to Request for Additional Information (Acc. ML19128A342) Response Time Extension Project stage: Response to RAI ML21188A2092021-06-0909 June 2021 Kansas State Univ., Request for Additional Information (Acc. ML19128A342) Response Time Extension Project stage: Request ML21166A3332021-07-0808 July 2021 Kansas State University - Response to Request for Extension of Time to Respond to Request for Additional Information Regarding License Amendment Request for the Use of 12 Percent by Weight Uranium Fuel Elements Project stage: RAI ML22172A0102022-05-27027 May 2022 Kansas State Univ., Request for Additional Information (Acc. ML19128A342) Response Time Extension Project stage: Request ML22153A5192022-06-27027 June 2022 Kansas State Univ, Response to Request for Extension of Time to Respond to RAI Regarding Lic Amend Request Project stage: RAI 2020-10-05
[Table View] |
Text
US Nuclear Regulatory Commission Washington, DC 20555-0001 7 October 2019 KANSAS STATE UNIVERSITY TRIGA Mk II Nuclear Reactor Laboratory
Subject:
Facility Response to 6/5/2019 Request for Additional Information (Acc.# ML19128A342) and Teleconferences Summary (Acc. # ML19248C834)
To Whom It May Concern, On June 5, 2019, the NRC sent another Request for Additional Information (RAI) to the Kansas State University (KSU) nuclear reactor facility (license R-88, docket 50-188) regarding a license amendment request (LAR) originally submitted on April 9, 2012 (Acc.# ML1219A063) to add up to four 12%-loaded fuel elements to the core. Additional discussion regarding the LAR and RAI progress was conducted by teleconference on September 3 and September 16, 2019.
The most recent RAI included a response date of 7 October 2019. At this point, the facility requests additional time to respond. Based on an estimate of time required to complete the RAI, the facility is requesting an extension to 7 January 2020. The additional 90 days will allow for refining simulation models and adequate computation time for benchmarking.
As discussed during the teleconferences (September 3 and September 16, 2019), the facility will administratively impose the following operating restrictions during the LAR review:
- 1.
No reactor operation with core excess reactivity significantly greater than*its current value (i.e.,
more than $0.15 above the current core excess reactivity), except low power reactor operation that may be necessary to make measurements needed to determine excess reactivity.
- 2.
No reactor operation when the bulk pool temperature is above 50 °C (112 °F).
- 3.
No reactor operation when experiments or other objects are inserted in interstitial flux wire ports in the grid plate and the bulk pool temperature is above 37 °C (98.6 °F).
- 4.
No reactor operation when one or more control rods is inoperable.
Advanced notific'ation to the NRC will be provided if KSU plans to change these operational practices prior to completion of the LAR review.
I swear under penalty of perjury that the foregoing is true and correct.
- Regards, Alan T. Cebula Nuclear Reactor Facility Manager Alan Levin Department of Mechanical and Nuclear Engineering Kansas State University
Manhattan, KS 66506 Phone: (785)532-6657 Fax:
(785)532-7057 Email: alanc@ksu.edu cc:
Linh Tran, Project Manager Edward Helvenston, Project Manager 2