Notifies of Completion of Generic Bounding Review Re Inadvertent Safety Injection During Cooldown.No Further Licensing Action Necessary Since Facility Could Most Likely Withstand More than 50 ECCS Actuations
ML19294C064
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 12/28/1979
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Mayer L
NORTHERN STATES POWER CO.
References
NUDOCS 8003060627
Download: ML19294C064 (1)


Text

NW Docket Nos. 50-282 and 50-306 Mr. L. O. Hayer, Manager D ]l[lgh Nuclear Support Services fn@

n 3f' j q

Northern States Pcwer Ccepany j

k ta 414 Nicollet Mall - 8th Floor UUl Minneapolis, Minnesota 55401

Dear Mr. Mayer:

SUBJECT:

IMADVERTENT SAFETY IMJECTION DURING COCLD0W The Division of Operating Reactors has corpleted a generic bounding review on this subject and concludes that no further licensing action is necessary at this tice since it is likely that a facility could withstand core than fifty inadvertent ECCS actuations. We have concluded, hwever, that it wculd be pn: dent, should a facility experience ricre than t.;cnty-five such injections, for you to consider a plant specific analysis for that facility which would identify ricre precisely the additicnal nunber of actuations that can be safely accornodated at that facility.

A copy of our Safety Evaluation Report is enciesed.

Si ncerely, A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Enclesure:

Safety Evaluation ec: w/enclosunt See next page Y

Omcc)..D02:0RBI....... DOR:0RRI.....

....... #.0.0.40.60.62Z.

su R N.M e >..nsnitenhets:sbAschwenar DATEM. 12/. /79........12/.. fJ9...

... c..

NRC FORM 318 (9 76) NRCM C240 DU.S. GOVE RNMENT PRINTING FFI Es 1979 289 369