Amend 28 to License DPR-72,deleting One Isolation Device & Adding Others to Provide post-accicent Containment Atmosphere Sampling Capability
ML19294B369
Person / Time
Site: Crystal River 
Issue date: 02/15/1980
From: Reid R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19294B370 List:
References
NUDOCS 8002280249
Download: ML19294B369 (7)


Text

.

ff

),

UNITED STATES y

efj NUCLEAR REGULATORY COMMISSION

"'/

2 WASHING TON. D. C. 20555 o

jf FLORIDA POWER CORPORATION CITY OF ALACHUA CITY OF BUSHNELL CITY OF GAINESVILLE CITY OF KISSIMMEE CITY OF LEESBURG CITY OF NEW SMYRNA BEACH AND UTILITIES COMMISSION, CITY OF NEW SMYRNA BEACH CITY OF OCALA ORLANDO UTILITIES COMMISSION AND CITY OF ORLANDO SEBRING UTILITIES COMMISSION SEMINGLE ELECTRIC COOPERATIVE, INC.

CITY OF TALLAHASSEE DOCKET NO. 50-302 CRYSTAL RIVER UNIT 3 NUCLEAR GENERATING PLANT AMEN 3 MENT TO FACILITY OPERATING LICENSE Amendment No. 28 License No. DPR-72 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The apolicaticr. for amendment by Florida Power Corporation, et al (the licensees) dated February 14, 1980, complies with the standards and requirements of the Atomic Emr.rgy Act of 1954, as amended (the Act), and tre Commission's ruler and regulations set forth in 10 CFR Chapter I, B.

The facil~ity will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commissien; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the cc= mon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 1C CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

8 0 02 280M 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.f. (2) of Facility Operating License No. DPR-72 is hereby ament.ed to read as follows:

(2). Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 28 are hereby incorporated in the license.

Florida Power Corporation shall operate the facility in accordance with the Technical S,pecifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION JY' ]vb-t z

~

Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance: February 15, 1980

ATTACHMENT TO LICENSE AMENDMENT NO. 28 gr!LITYOPERATINGLICENSENO.OPR-72 DOCKET NO. 50-302 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change. The corresponding overleaf pages are also provided to maintain document completeness.

Paces 3/4 6-20 3/4 6-21

t 9

TABLE 3.6-1 (Continued)_

C0KTAINMENT ISOLATION VALVES VALVE NUM3ER FUNCTION ISG;.ATION TIME (seconos) 9.

(Continued)

MUV-163 check #

open during HPI and NA MUV-25 i iso. dur. nor. operation 60 MUV-164 check i NA MUV-26 i 60 MUV-160 check !

open during HPI and NA MUV-23

  • iso. dur. nor operation 60 MUV-161 check #

open during HFI and NA MUV-24 i iso dur. nor, operation 60 MUV-27 7 open dur. nor. operation 60 and closed during RB isolation

10. SWV-39 f iso. NSCCC from AHF-lC 60 SWV-45 f 60 SWV-35
  • iso. NSCCC from AHF-1 A 60 SWi-41 7 60 SWV-37
  • iso. NSCCC from AHF-1B 60 SWV-43 5 60 SWV 45 f to isolate NSCCC from 6C SWV 47 s MUHE-1 A & 15 and WDT-5 60 SW'. -49
  • 60 SWV-50 #

60 SWV-B0 #

iso. NSCCC from RCP-1 A 60 SWV-84 7 60 SWV-82.*

iso. NSCCC frm RCP-lC 60 SWV-86 j 60 SWV-81 f iso. NSCCC from RCP-lO 60 SWV-85 #

60 SWV-79 i iso. NSCCC fro RCP -1B 60 SWV-83

  • 60 SWV -109 =

NSCCC to DRRD-1 6C SWV-110=

60 CRYSTAL RIVER - UNIT 3 3/4 6-19 Amendment Nc 77,24' SEP S 1979

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES VALVE NUMBER FUNCTION ISOLATION TIME (seconds)

11. WDV-4 iso. WDT-4 from RB sump 60 WDV-3 60 WDV-60 & 61 iso. WDT-4 from WDT-5 60 WDV-94 & 62 iso. WDT-4 from WDP-8 60 WDV-406 iso. gas waste disposal 60 WDV 405 from vents in RC system 60
12. WSV-3 iso. containment monitoring 60 WSV system from RB 60 WSV-5 60 WSV-6 60 B.

CONTAINMENT PURGE AND EXHAUST 1.

AHV-lC & ID iso. pur. sup. system 60 AHV-15 & 1A iso. pur. exhaust system 60 C.

MW. L.

1.

IAV-25 iso. IA from RB NA IAV-29 NA 2.

LRV-5C iso. leak rate test system NA LRV-36 from RB NA LRV-51 iso. atmos. vent and RB NA LRV-35 & 47 purge exhaust system NA from RB LRV 49 iso. atmos. vent from RB NA LRV-38 & 52 NA LRV 45 iso. LR test panel from RB NA LPV a NL

-4 l

n r, 3.

MSt-146=

iso. misc. waste storage NA tank f rom RCSG-13 4.

NGV-62 iso. NG system from NA NGV-Ei F stear generators NA NGV-82 iso. NG system from pzr.

NA CRYSTAL RIVER - UNIl 3 3/4 6-20 Amendment No. 28

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES VALVE NUMBER FUNCTION ISOLATION TIME (seconds)

NA 5.

SAV-24 iso. SA from RB NA l

h.'

s I.

6.

SFV-18 iso. SF system NA NA SFV-19 SFV-119=

iso. Fuel Transfer tubes NA SFV-120*

from F.T. Canal NA 7.

WSV-1 containment monitorino NA WSV-2 system from RB NA D.

PENETRATIONS REQL'!R!NS TYPE B TESTS Blind Flance 119 isc. RE NA Slinc Flanie 120 NA NA Blind Flange 202 Blind Flange 348 iso. fuel transfer tube from NA Blind Flange 436 Transfer Canal NA Equipment Hatch iso. RS NA Personnel Hatch iso. RS NA

  • Not subject to Type C Leakage Test
    • The provisions of Specification 3.0.4 are not applicable until startup for Cycle 3 operation.

Isolation valves closed tc satisfy the require-ments of Soecification 3.6.3.1 ACTION b. and c. may be re-opened on an intermittent basis under administrative control for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in any 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period as necessary for sampling.

CRYSTAL RIVER - UNIT 3 3/4 6-21 Amendment No. 2 7, 28

CONTAINMENT SYSTEMS 3/4.0.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 A containment hydrogen analyzer and a gas chromatograph shall be OPERABLE.

APPLICABILITY' MODES 1 and 2.

ACTION:

With one hydrogen analysis device inoperable, restore the inoperable device to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REOUIREMENTS 4.6.4.1 Each hydrogen analysis device shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performin' a CHANNEL CALIBRATION using sample gases containing:

a.

One volume percent hydrogen, balance nitrogen, and b.

Four volume percent hydrogen, balance nitrogen.

CRYSTAL RIVER - UNIT 3 3/4 6-22