ML19294B255
| ML19294B255 | |
| Person / Time | |
|---|---|
| Site: | La Crosse File:Dairyland Power Cooperative icon.png |
| Issue date: | 02/04/1980 |
| From: | Ziemann D Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML19294B245 | List: |
| References | |
| NUDOCS 8002280053 | |
| Download: ML19294B255 (2) | |
Text
,
7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION DOCKET NO. 50-409 DAIRYLAND POWER COOPERATIVE NOTICE OF ISSUANCE OF AMENDMENT TO PROVISIONAL OPERATING LICENSE The U. S. Nuclear Regulatory Commission (the Commission) has issued Amendment No. 19 to Provisional Operating License No. DPR-45, issued to Dairyland Power Cooperative (the licensee), which revised the Technical Specifications for operation of the La Crosse Boiling Water Reactor (LACBWR) located in Vernon County, Wisconsin.
The amendment is effective as of its date of issuance.
The amendment modifies the Technical Specifications for the LACBWR by adding new, more restrictive limits for the reactor coolant and off-gas radioactivity to compensate for increasing the maximum average fuel assembly exposure by 600 MWD /MTU. These limits apply only to fuel cycle 6 operation and would pennit continued reactor operation while the new spent fuel racks are being installed in the fuel storage well.
The application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations.
The Commission has made appropriate findings as required by the Act and the Commission's rules and regulations in 10 CFR Chapter I, which are set forth in the license amendment.
Prior public notice of this amendment was not required since the amendment does not involve a significant hazards consideration.
8 0 0 2 2800Q,
7590-01 The Conmission has determined that the issuance of this amendment will not result in any significant environmental impact and that pursuant to 10 CFR 551.5(d)(4) an environmental impact statement or negative declaration and environmental impact appraisal need not be prepared in connection with issuance of this amendment.
For further details with respect to this action, see (1) the application for amendment dated January 17, 1980, and supplement thereto dated January 28, 1980, (2) Amendment No.19 to License No. DPR-45, and (3) the Commission's related Safety Evaluation. All of these items are available for public inspection at the Conmission's Public Document Room,1717 H Street, N. W.,
Washington, D. C. and at the La Crosse Public Library, 800 Main Street, La Crosse, Wisconsin 54601.
A copy of items (2) and (3) may be obtained upon request addressed to the U. S. Nuclear Regulatory Commission, Washington, D. C.
20555, Attention:
Director, Division of Operating Reactors.
Dated at Bethesda, Maryland, this 4th day of February, 1980.
F THE NUCLEAR REGULATORY COMMISSION
/) 9 (kn.,m 6,W m>i Dennis L. Ziemann, Cf ef Operating Reactors Branch #2 Division of Operating Reactors