ML19294B179
| ML19294B179 | |
| Person / Time | |
|---|---|
| Site: | Arkansas Nuclear |
| Issue date: | 01/04/1980 |
| From: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Cavanaugh W ARKANSAS POWER & LIGHT CO. |
| Shared Package | |
| ML19294B180 | List: |
| References | |
| NUDOCS 8002270479 | |
| Download: ML19294B179 (2) | |
See also: IR 05000313/1979026
Text
7/.
C
.
UNITED STATES
/# "' 4,#':,
NUCLEAR REGULATORY COMMISSION
- ' . *
+/ %
REGloN IV
,
0
611 RY AN PL AZA D9IVE, SULTE 1000
7
h,
ARLINGTON, TEX AS 76012
"r
,
,
-(;
<,%,,,,,.-
January 4, 1980
In Reply Refer To:
Docket Nos. 50-313/79-26
50-368/79-25
Arkansas Power and Light Company
ATTN:
Mr. William Cavanaugh III
Vice President of Generation
and Construct _on
P. O. Box 551
Little Rock, Arkansas 72203
Gentlemen:
This refers to the inspection conducted in conjunction with the Resident
Inspection Program by Messrs. R. G. Spangler and L. A. Yandell of this
office covering the period of December 17-20, 1979, of activities authorized
by NRC Facility Operating License Nos. DPR-51 and NPF-6 for the Arkansas
Nuclear One, Units 1 and 2, and to the discussion of the findings by the
inspectors with members of your staff at the conclusion of the inspection.
Areas examined during the inspection and our findings are discussed in the
enclosed inspection report. Within these areas, the inspection consisted
of selective examination of procedures and representative records, interviews
with personnel, and observations by the inspectors.
Within the scope of
this inspection, no items of noncompliance were identified.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room.
If the
report contains any information that you believe to be proprietary, it is
necessary that you submit a written application to this office within 20 days
of the date of this letter, requesting that such information be withheld
from public disclosure. The application must include a full statement of the
reasons why it is claimed thct the information is proprietary.
The application
should be prepared so that any proprietary information identified is contained
in an enclosure to the application, since the application without the enclosure
will also be placed in the Public Document Room.
If we do aot hear from you in
this regard within the specified period, the report will be placed in the Public
Document Room.
8002270
'
-
.
.
Arkansas Power and Light Company
-2-
January 4, 1980
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely,
Ye [i
h
G. L. Madsen, Chief,
Reactor Operations and
Nuclear Support Branch
Enclocure:
IE Inspection Report Nos. 50-313/79-26
50-368/79-25
cc w/ enclosure:
.
Arkansas Nuclear One
ATTN:
J. P. O'Hanlon, Manager
P. O. Bo:t 608
Russellville, Arkansas
72801