Text
SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT C) 6201 S Street, Box 15830, Sacramer*o, California 95813; (916) 452-3211 February 19, 1980 Mr. R. H. Engelken, Director Region V Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission 1990 North California Boulevard Walnut Creek Plaza, Suite 202 Walnut Creek, California 94396 Re: Operating License DPR-54 Docket No. 50-312 Reportable Occurrence 80-11
Dear Mr. Engelken:
Sacramento Municipal Utility District has measured degradation of Once Through Steam Generator tubes.
Steam Generator Unit A has one tube determined degraded and Steam Generator Unit B has two tubes degraded.
Corrective action is underway. This report is being submitted to you within the requirements of Regulatory Guide 1.16 Section C.2.a(3) and Technical Specifications Sectien 6.9.4.l(c).
The Rancho Seco Resident Inspector was notified today.
Respectfull' ubmitted, fwt/
R. P. Oubre' Acting Manager, Nuclear Operations RPO:RWC:jr YkD 8002270JRf39 AN ELECTRIC SYSTEM S E RVIN G MORE THAN 600,000 IN THE HEAnt OF
.